Directory Search Results

Print List

#2012362

Shower waste water heat recovery unit, consisting of a PVC-U waste pipe with an internal copper tube which provides a double wall separation between the waste water and cold mains supply. Maximum working pressure 10.0 bar. Maximum operating temperature 30°C.

Section:
1350 Heat Exchangers
Size:
½” BSP (F).
Marking:
Recoup logo, pipe ID outside wall, PVC-U 63x2.0, 16028740 kiwa, 5 16-01-19 11.40, PVC MET HERGERBUIKGRANTIE on adhesive label on outside wall.
Installation Requirements:
R001 R008
Expiry date:
31/12/2025
Model:
Recoup Pipe HEX: R-PHX-01 (2.1m length). Recoup Pipe HEX-Rd: R-PHX-03 (1.7m length).

Approval Holder:
Recoup Energy Solutions Ltd.
Company Name
Recoup Energy Solutions Ltd.
Address
Trumpeter House Trumpeter Rise Long Stratton
Postcode
NR15 2DY
Country
United Kingdom
Phone
+441379844010
General Email
ian@recoup.co.uk

View All Listings by this Company

Print This Approval


#2012365

Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.

Section:
1350 Heat Exchangers
Size:
¾” BSP (M)
Marking:
BAXI ON FRONT OF CASING. BAXI, address, serial number, technical & pressure information on label inside case.
Installation Requirements:
R001
Expiry date:
31/12/2025
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
BAXI ASSURE HIMAX TWIN ID 90/30 ELECTRONICALLY CONTROLLED HEAT INTERFACE UNITS

Approval Holder:
Baxi Heating UK Limited
Company Name
Baxi Heating UK Limited
Address
Brooks House, Coventry Road, Warwick
Postcode
CV34 3LL

View All Listings by this Company

Print This Approval


#2101041

Gas fired water heaters incorporating a heat exchanger and flow sensor. The inlet incorporates a plastic strainer. The products are supplied with isolation valves for installation on the cold inlet and hot outlet. Maximum working pressure 10.0 bar. Maximum operating temperature 60˚C

Section:
1400 Heaters
Section Subtitle:
Gas fired, closed outlet. Heat retained in water heaters may cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to prevent excess pressure within the system.
WRAS Approval Number:
2101041
Size:
15mm Compression
Marking:
ECA on front of body. ECA. Model & technical information on adhesive label on side of body.
Installation Requirements:
R001 R140
Expiry date:
31/01/2026
Model:
8116180100 – Phoenix PH 11LT Water Heater.
Product Images

Approval Holder:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Mustafa Kemal Blv. No:13 Keçiliköy Osb/Yunusemre Manisa
Postcode
45030
Country
Turkey
General Email
egecakmakci@emas.com.tr

View All Listings by this Company
Manufacturer:
Emas Makina Sanayi A.S.
Company Name
Emas Makina Sanayi A.S.
Address
Mustafa Kemal Blv. No:13 Keçiliköy Osb/Yunusemre Manisa
Postcode
45030
Country
Turkey
General Email
egecakmakci@emas.com.tr

View All Listings by this Company

Print This Approval


#2012043

Range of gas fired condensing water heaters incorporating stainless steel storage tank, buffer tank and strainer on the cold water inlet. Maximum working pressure 10.0 Bar, maximum working temperature 83˚C.

Section:
1400 Heaters
Section Subtitle:
Gas fired, closed outlet. Heat retained in water heaters may cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to prevent excess pressure within the system.
WRAS Approval Number:
2012043
Marking:
NAVIEN on front of unit, NAVIEN, model and technical information including pressures on adhesive label on side of unit.
Installation Requirements:
R001
Expiry date:
31/12/2025
Model:
NPE – 24SWE NPE – 32SWE NPE – 24AWE NPE – 32AWE
Product Images

Approval Holder:
KD Navien Co Ltd
Company Name
KD Navien Co Ltd
Address
4F Koami Bldg, 22 Gukhoe daero, 76-gil, Yeongdeungpo-gu, Seoul, 07238 Korea
Phone
+82 2 3489 2200
General Email
www.navien.com

View All Listings by this Company
Manufacturer:
KD Navien Co Ltd
Company Name
KD Navien Co Ltd
Address
4F Koami Bldg, 22 Gukhoe daero, 76-gil, Yeongdeungpo-gu, Seoul, 07238 Korea
Phone
+82 2 3489 2200
General Email
www.navien.com

View All Listings by this Company

Print This Approval


#2101042

LCB700 range of internal and external oil-fired condensing combination boilers providing domestic hot water and pressurised central heating via a plate heat exchanger. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The primary (space heating) circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). Operating parameters: Primary (space heating) circuit: Maximum working pressure 2.5 Bar. Maximum operating temperature 105°C. Secondary (DHW) circuit: Maximum working pressure 10.0 Bar. Maximum operating temperature 85°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2101042
Size:
Primary (space heating) circuit: 22mm pushfit. Secondary (DHW) circuit: 15mm pushfit.
Marking:
Navien, model and technical information on adhesive label on rear of front cover.
Installation Requirements:
R001 R140 R360 R430
Expiry date:
31/01/2026
Model:
Internal: LCB700-21LC. LCB700-28LC. LCB700-36LC. External: LCB700-21LCX. LCB700-28LCX. LCB700-36LCX
Product Images

Approval Holder:
KD Navien Co Ltd
Company Name
KD Navien Co Ltd
Address
4F Koami Bldg, 22 Gukhoe daero, 76-gil, Yeongdeungpo-gu, Seoul, 07238 Korea
Phone
+82 2 3489 2200
General Email
www.navien.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 166 of 2264

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.