Directory Search Results

Print List

#2204110

‘AF’ range of compression fittings with brass or chrome plated brass bodies for use with copper pipe (manufactured to EN1057). Maximum working pressure 16.0 bar. Maximum working temperature 85˚C

Section:
1180 Fittings for use with Tube and Pipe
Section Subtitle:
Couplings. Unless specified in the individual approval, the products within this section are not suitable for below ground use
WRAS Approval Number:
2204110
Size:
see model
Marking:
Plumb Bliss logo (PB), Size & month/year of manufacture on fitting body
Installation Requirements:
R001
Expiry date:
30/04/2027
Model:
10.1272 Plumb Bliss Compression Coupler Male 15mm x 1/2" 10.1273 Plumb Bliss Compression Coupler Male 15mm x 3/4" 10.1274 Plumb Bliss Compression Coupler Male 22mm x 1/2" 10.1275 Plumb Bliss Compression Coupler Male 22mm x 3/4" 10.1276 Plumb Bliss Compression Coupler Female 15mm x 1/2" 10.1277 Plumb Bliss Compression Coupler Male 15mm x 3/4" 10.1278 Plumb Bliss Compression Coupler Male 22mm x 1/2" 10.1279 Plumb Bliss Compression Coupler Male 22mm x 3/4" 10.1280 Plumb Bliss Brass Compression Tee 15mm x 15mm x 1/2" 10.1281 Plumb Bliss Wall Plate Compression Elbow 15mm x 1/2"

Approval Holder:
Bliss UK Group Ltd
Company Name
Bliss UK Group Ltd
Address
Unit 4A Kinsbourne Farm Wick End Stagsden Bedfordshire
Postcode
MK43 8TS
Country
United Kingdom
Phone
01234 860230
General Email
accounts@blissukgroup.co.uk

View All Listings by this Company

Print This Approval


#2311107

Range of WC dual flush drop valves with ABS bodies and silicone seals. The valves are operated via a two push button assembly for either full or reduced flush and incorporate an internal overflow. Cold water use only.

Section:
1305 Flushing Mechanisms
Section Subtitle:
WC. Except where specified, flushing valves within this section have only completed a limited number of the performance and endurance tests as stated in the "Regulators Specification for WC suites installed after 1st January 2001". The flush volume of valves within this section have not been verified by test. When installed in combination with a WC cistern and pan, further performance tests will be required.
WRAS Approval Number:
2311107
Size:
2” BSP (M)
Marking:
Plumb Bliss, logo & company website on bottom. WRAS & technical data on side.
Installation Requirements:
R001 R571 R580 R581
Expiry date:
30/11/2028
Model:
10.1260

Approval Holder:
Bliss UK Group Ltd
Company Name
Bliss UK Group Ltd
Address
Unit 4A Kinsbourne Farm Wick End Stagsden Bedfordshire
Postcode
MK43 8TS
Country
United Kingdom
Phone
01234 860230
General Email
accounts@blissukgroup.co.uk

View All Listings by this Company

Print This Approval


#250801701

Range of urinal autosyphons with plastic body and supplied with plastic backnuts.

Section:
1307 Flushing Mechanisms
Section Subtitle:
Urinals.
WRAS Approval Number:
250801701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Please refer to model.
Marking:
B.B.S Auto Syphon, BS 1876 tested & Masefield Beta Ltd. on outer body
Installation Requirements:
R001
Expiry date:
31/08/2030
Model:
BBS Auto Syphon range consisting of; Size 1 - 4.5 litre (1 Gallon): 5½’’ X 1” BSP outlet. 5½’’ X 1¼” BSP outlet. Size 2 - 9 litre (2 Gallon): 6¼’’ X 1” BSP outlet. 6¼’’ X 1¼” BSP outlet. Size 3 - 13.5 litre (3 Gallon): 7½’’ X 1” BSP outlet. 7½’’ X 1¼” BSP outlet. Size 4 - 18 litre (4 Gallon): 8¼’’ X 1” BSP outlet. 8¼’’ X 1¼” BSP outlet. Size 5 - 22.5 litre (5 gallon): 9¼’’ X 1” BSP outlet. 9¼’’ X 1¼” BSP outlet.

Approval Holder:
Thomas Dudley Limited
Company Name
Thomas Dudley Limited
Postcode
DY1 4SJ
Country
United Kingdom
Phone
0121 530 7053
General Email
jcresswell@thomasdudley.co.uk

View All Listings by this Company
Manufacturer:
Thomas Dudley Limited
Company Name
Thomas Dudley Limited
Postcode
DY1 4SJ
Country
United Kingdom
Phone
0121 530 7053
General Email
jcresswell@thomasdudley.co.uk

View All Listings by this Company

Print This Approval


#250602716

Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. Some models, please refer to model below, incorporate only a primary circuit. Maximum working pressures: Primary circuit: 2.5 bar, Secondary circuit 10.0 bar. Maximum operating temperature both circuits: 60°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
250602716
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Marking:
Warmhaus on front panel. Warmhaus, product name and operating info on label on side panel
Installation Requirements:
R001 R140 R360
Expiry date:
30/06/2030
Model:
Following models are ¾” BSP M inlet/outlet primary circuit, ½” BSP M inlet/outlet secondary circuit. KM0725250101005901 EWA 2525C 25KW KM0725300101005901 EWA 2530 C 30 KW KM0725310303008701 MINERWA 25/31 COMBI BOILER IE (BLACK) KM0725300201008901 ENERWA PLUS 2530 C - UK KM0325300201001301 ENERWA PLUS 2530 C - UK + FLUE KIT KM0730350201008901 ENERWA PLUS 3035 C - UK KM0330350201001301 ENERWA PLUS 3035 C + F.KIT - DHW 35 - UK KM0735400201008901 ENERWA PLUS 3540 C - UK KM0335400201001301 ENERWA PLUS 3540 C - UK KOMBI KM0742400201001301 ENERWA PLUS 4240 C 40 KW - UK KM0745430201001301 ENERWA PLUS 4543 C 43 KW - UK KM0725310303009801 EXP.MINERWA 25 SYSTEM BOLER (BLACK) KM1220240101012201 GLOWA 2024 KM1224260101012201 GLOWA 2426 KM1228300101012201 GLOWA 2830 KM1233350101012201 GLOWA 3335 KM1220240101012401 GLOWA SMART 20/24 20KW KM1224260101012401 GLOWA SMART 24/26 24KW KM1228300101012401 GLOWA SMART 28/30 28KW KM1233350101012401 GLOWA SMART 33/35 33KW Following models are ¾” BSP M inlet/outlet and are primary circuit only KM1024000201005501 EXP.ENERWA PLUS H.O 2500H KM1024000201010201 EXP. WARMHAUS ENERWA PLUS H.O 2500H - UK KM1028000201005501 EXP.WARMHAUS ENERWA PLUS H.O 3000H KM1028000201010201 EXP.WARMHAUS ENERWA PLUS H.O 3000H - UK KM1033000201005501 EXP.WARMHAUS ENERWA PLUS H.O 3500H KM1033000201010201 EXP.WARMHAUS ENERWA PLUS H.O 3500H - UK KM1133000201005501 EXP.WARMHAUS ENERWA PLUS H.O 3500H+F.KIT KM1133000201006201 EXP.WARMHAUS ENERWAPLUS HO 3500H-D+F.KIT KM1142000201005501 ENERWA PLUS H.O 4200H KM1145000201005501 ENERWA PLUS H.O 4500H KM1220000101012301 GLOWA 20 H.O. KM1224000101012301 GLOWA 24 H.O. KM1228000101012301 GLOWA 28 H.O. KM1233000101012301 GLOWA 33 H.O.

Manufacturer:
Warmhaus Isitma VE Sogutma Sistemleri Sanayi Ticaret A.S.
Company Name
Warmhaus Isitma VE Sogutma Sistemleri Sanayi Ticaret A.S.
Address
Nilufer Organise Sanayi Bolgesi Selvi Cad No:3 Nilufer Bursa Turkey
Phone
+90-224-2959400

View All Listings by this Company

Print This Approval


#250604027

Range of SSM-AQUO ultrasonic water meters with brass bodies, the inlets incorporate a plastic filter. Maximum working pressure 16.0 bar. Maximum operating temperature 60°C.

Section:
1505 Water Meters
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
3/4” BSP (M) 7/8” BSP (M) 1” BSP (M) 1-1/4” BSP (M) 1-1/2” BSP (M) 2” BSP (M)
Marking:
Pietro Fiorentini logo moulded on cap. Pietro Fiorentini logo, pressure, flow, year of manufacture (YYYY) and other technical information printed on meter face. Flow arrow and DN moulded on body.
Installation Requirements:
R001
Expiry date:
30/06/2030
Model:
SSM-AQUO DN15 - DN40

Approval Holder:
Pietro Fiorentini S.p.A.
Company Name
Pietro Fiorentini S.p.A.
Address
Via E. Fermi, n. 8/10-36057 Arcugnano (VI).
Country
Italy
General Email
mario.petti@fiorentini.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1610 of 1714

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.