Directory Search Results

Print List

#241002101

Range of stainless-steel braided flexible hose assemblies incorporating EPDM inner and plastic (BFSFH12-EE80/150) or brass (BFSFH19-EE60) captive nut end connections. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
1863 Tubes
Section Subtitle:
Elastomeric.
WRAS Approval Number:
241002101
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
3/4” BSP X 3/4” BSP ELBOW.
Marking:
MIDBRASS®, WRAS and Year of manufacture (YYYY).
Installation Requirements:
R001 R008
Expiry date:
31/10/2029
Model:
BFSFH12-EE80, BFSFH19-EE60 & BFSFH12-EE150.

Approval Holder:
Monarch Water Ltd
Company Name
Monarch Water Ltd
Address
Fair Green Diss Norfolk
Postcode
IP22 4DG
Country
United Kingdom
Phone
01986 784759
General Email
kdelaney@monarchwater.co.uk

View All Listings by this Company
Manufacturer:
Navigator MSL Ltd.
Company Name
Navigator MSL Ltd.
Address
Mill Road, Sharnbrook, Beds.
Postcode
MK44 1NP
Phone
01234 781234
General Email

View All Listings by this Company

Print This Approval


#240988026

Range of stainless steel inter-locked shower hoses incorporating PVC linings in various finishes. Maximum operating temperature 65°C.

Section:
1863 Tubes
Section Subtitle:
Elastomeric.
WRAS Approval Number:
240988026
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
Open outlet use only
Size:
See model
Marking:
Aqualisa on ferrule
Installation Requirements:
R001 R040
Expiry date:
30/09/2029
Model:
ACY1008 1.5M METAL HOSE CHROME

Approval Holder:
Aqualisa Products Ltd.
Company Name
Aqualisa Products Ltd.
Address
Unit 6 The Flyers Way, Westerham, Kent
Postcode
TN6 1DE
Phone
07920 790367
General Email
tracey.jones@aqualisa.co.uk

View All Listings by this Company

Print This Approval


#250102704

Range of unvented storage cylinders. The secondary circuit is fitted with a temperature and pressure relief valve set at 7.0 bar at 90˚C and an expansion relief valve set at 6.0 bar. The product is supplied with a safety group consisting of a pressure reducing valve set at 3.0 bar, and an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Also Supplied with an expansion vessel and tundish. Maximum working pressures: Primary circuit: 5.5 bar Secondary circuit: 6.0 bar Solar circuit:6.0 bar Maximum operating temperature 85.0°C

Section:
1890 Unvented Heating Apparatus
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
22mm compression all connections
Marking:
Joule, model name, capacity, pressure ratings and other technical information on adhesive label on cylinder
Installation Requirements:
R001 R140 R360
Expiry date:
31/01/2030
Model:
TRSMVD-0090LFC TRSMVD-0120LFB TRSMVD-0150LFB TRSMVD-0180LFB TRSMVD-0210LFC TRSMVD-0250LFC TRSMVD-0300LFC TRSMVI-0090LFC TRSMVI-0120LFB TRSMVI-0150LFB TRSMVI-0180LFB TRSMVI-0210LFC TRSMVI-0250LFC TRSMVI-0300LFC TRSMVS-0150LFB TRSMVS-0180LFB TRSMVS-0210LFC TRSMVS-0250LFC TRSMVS-0300LFC
Product Images

Manufacturer:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company

Print This Approval


#250302708

Range of indirect unvented storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar @ 90˚C. The product is supplied with an inlet control group (safety kit) consisting of a pressure reducing valve pre-set at 3.0 bar, strainer, an expansion relief valve set at 6.0 bar and a check valve cartridge (verified by test - suitable for backflow protection against Fluid Category 2). A tundish and expansion vessel are also provided Maximum working pressure: Primary circuit: 6.0 Bar Secondary circuit: 5.5 bar Maximum operating temperature: 85.0°C

Section:
1890 Unvented Heating Apparatus
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Primary circuit: 1” BSP (F) Secondary circuit: 22mm compression
Marking:
Joule logo, model and technical information on adhesive label on body
Installation Requirements:
R001 R140 R360
Expiry date:
31/03/2030
Model:
TRJMVH -0150LFB 150 Cyclone Plus High Gain Indirect Standard TRJMVH -0180LFB 180 Cyclone Plus High Gain Indirect Standard TRJMVH -0210LFC 210 Cyclone Plus High Gain Indirect Standard TRJMVH -0250LFC 250 Cyclone Plus High Gain Indirect Standard TRJMVH -0300LFC 300 Cyclone Plus High Gain Indirect Standard TRJMVH -0150SFB 150 Cyclone Plus High Gain Indirect Slim TRJMVH -0180SFB 180 Cyclone Plus High Gain Indirect Slim TRJMVH -0210SFC 210 Cyclone Plus High Gain Indirect Slim
Product Images

Manufacturer:
Joule Hot Water Systems UK Ltd
Company Name
Joule Hot Water Systems UK Ltd
Address
Unit 3, Leftfield Park, Park Road Pontefract, West Yorkshire WF8 4PS

View All Listings by this Company

Print This Approval


#250304703

Range of 2, 3, 4, 5 or 6 port manifold assemblies with brass bodies. The products incorporate a spherical valve with a plastic ball on either the inlet or on each outlet (see model). Maximum working pressure 10.0 bar. Maximum operating temperature 95°C

Section:
1950 Manifolds
Section Subtitle:
Metal.
WRAS Approval Number:
250304703
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Fastec® F13 internal Ø 20.75 - 20.93mm
Marking:
Teco logo, DN, PN, year and batch/month (YYMM) and F13 on body.
Installation Requirements:
R001
Expiry date:
31/03/2030
Model:
Manifold with valve on each outlet: DN2309727: DN10 Manifold 2 ways F13F, DN2105548: DN10 Manifold 3 ways F13F, DN1901798: DN10 Manifold 4 ways F13F, DN1901797: DN10 Manifold 5 ways F13F, DN2309733: DN10 Manifold 6 ways F13F, Manifold with valve on inlet: DN2410745: DN15 Manifold 4 ways F13F, DN1901854: DN15 Manifold 5 ways F13F.
Product Images

Manufacturer:
TECO Srl
Company Name
TECO Srl
Address
Via Sandro Pertini n.39/41 25050 Provaglio d'Iseo (BS)
Country
Italy

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1469 of 1715

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.