Directory Search Results

Print List

#2012116

Bottom entry BS1212-4 (2016) compact type float operated inlet valve for WC flushing cisterns with a plastic body and adjustable float and a plastic flow regulator at the inlet. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2075 Float Operated Inlet Valve
Section Subtitle:
Can be used to achieve a recognised air gap arrangement, providing it meets the appropriate backflow requirements. Suitable for use in a WC suite, provided it forms an arrangement which meets the requirements of Type AUK1 air gap and an appropriate WC performance specification.
WRAS Approval Number:
2012116
Size:
½” BSP (M)
Marking:
UK Bathrooms Ltd & BS 1212-4 on body.
Installation Requirements:
R001 R550 R560
Expiry date:
31/12/2025
Model:
A122 fixed height fill valve

Approval Holder:
UK Bathrooms Ltd
Company Name
UK Bathrooms Ltd
Address
Aston House Redburn Road Newcastle Upon Tyne
Postcode
NE5 1NB

View All Listings by this Company

Print This Approval


#2301369

Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 3.5 litres. The cistern is operated by an electronically controlled flush valve. The product also incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2301369
Size:
½” BSP (M)
Marking:
Dolphin logo on flush panel Dolphin logo, Date of manufacturer DD.MM.YY on adhesive label, 6L & waterline mould on plastic support for flush valve
Installation Requirements:
R001 R556 R581
Expiry date:
31/01/2028
Model:
DB551x.E Dolphin Blue 126mm Electronic Cistern

Approval Holder:
Dolphin Solutions Limited
Company Name
Dolphin Solutions Limited
Address
Southpoint Compass Park Bodiam East Sussex
Postcode
TN32 5BS
Country
United Kingdom
General Email
Ralph.Mumford@dolphinsolutions.com

View All Listings by this Company

Print This Approval


#2111390

Range of concealed WC flushing cisterns incorporating a side entry compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve and flexible hose on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only. .

Section:
2035 Cistern - Flushing
Section Subtitle:
Incorporating Type AG air gap, providing fluid category 3 backflow protection. Suitable for use in a WC suite. Additional tests will need to be performed if required to demonstrate Type AUK1 air gap.
WRAS Approval Number:
2111390
Size:
½” BSP (M)
Marking:
Ideal Standard on Adhesive below insert within cistern: 6L waterline within cistern.
Installation Requirements:
R001 R556
Expiry date:
30/11/2026
Model:
R031767 Prosys 120 WC cistern Mech CL2 6L & R031867 Prosys 120 WC cistern Pneu CL2 6L

Approval Holder:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT
Country
United Kingdom
General Email
tyeomans@idealstandard.co.uk

View All Listings by this Company

Print This Approval


#240104701

Range of Type TK spring loaded, resilient trim, in-line check valve cartridges. For insertion into specifically dimensioned bores. Maximum working pressure 10.0bar. Maximum operating temperature 65ºC.

Section:
0026 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Check Valve Cartridge. The cartridges listed in this section are for factory installation only and are not suitable for on-site installation.
WRAS Approval Number:
240104701
Size:
see model
Marking:
Ocean, DN and model code and flow arrow on body. Model CO020 – Watts logo, DN15 and flow arrow on body
Installation Requirements:
R001
Expiry date:
31/01/2029
Model:
Model CO013 – DN10 W149013630 (Watts) or 149F043476 (Socla) Model CO015 – DN 10 149015630 (Watts) or 149F043478 (Socla) Model CO020 – DN 15 W149020630 (Watts) or 149F043479 (Socla) Model CO010 – DN 8 W149010630 (Watts) or 149F043475 (Socla) Model CO014 – DN10 W149014630 (Watts) or 149F043477 (Socla)
Product Images

Approval Holder:
Watts Industries France
Company Name
Watts Industries France
Address
100 Route Nationale F-80132 Hautvillers Ouville
Country
France
Phone
+02 37 251100 +33 3 22 60 39 80
General Email
info@wattsindustries.fr

View All Listings by this Company

Print This Approval


#240102708

Spring-loaded resilient trim in-line check valve cartridge with a plastic body, incorporating a stainless-steel spring and EPDM ‘O’-rings . For insertion into specifically dimensioned bores. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
0026 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Check Valve Cartridge. The cartridges listed in this section are for factory installation only and are not suitable for on-site installation.
WRAS Approval Number:
240102708
Size:
DN10
Marking:
Tecno Alfa logo, flow arrow and size on body
Installation Requirements:
R001
Expiry date:
31/01/2029
Model:
VLA05DN10
Product Images

Approval Holder:
Tecno Alfa S.R.L
Company Name
Tecno Alfa S.R.L
Address
Via Rossini, 27 Sale Marasino
Postcode
25057
Country
Italy
Phone
+39 030 986 587
General Email
info@technoalfa.net

View All Listings by this Company
Manufacturer:
Tecno Alfa S.R.L
Company Name
Tecno Alfa S.R.L
Address
Via Rossini, 27 Sale Marasino
Postcode
25057
Country
Italy
Phone
+39 030 986 587
General Email
info@technoalfa.net

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1445 of 2250

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.