Pumps

Section Code 1610 : Wholesome water use.

Back To Directory Sections

#2112057

Range of pumps with stainless steel bodies and plastic impellors. Maximum working pressure 16.0 bar. Maximum operating temperature 95°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2112057
Size:
1½” BSP (M) or 2” (M) inlet/outlet.
Marking:
Wilo SE, model and product info on data plate on body
Installation Requirements:
R001 R415
Expiry date:
31/12/2026
Model:
Para MAXO-Z 25-180-08. Para MAXO-Z 25-180-10. Para MAXO-Z 30-180-08. Para MAXO-Z 30-180-10.
Product Images

Approval Holder:
Wilo SE
Company Name
Wilo SE
Address
Werk Hof, Heimgartenstr. 1-3, 95030 Hof/Saale
Country
Germany

View All Listings by this Company

Print This Approval


#2201059

‘EVE Whole house’ twin impeller booster pump with a plastic body and impellers and EPDM ‘O’-rings. The inlet and outlet hoses incorporate a screwdriver operated isolation valve. The pump body outlets incorporate a non-return valve. The product is supplied with two loose combined EPDM and stainless steel inlet washers and two loose EPDM outlet washers. Maximum working pressure 3.0 bar. Maximum operating temperature 65°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2201059
Size:
Quadruple layered flexible hose consisting of a black coloured TPE inner layer, PVC middle layer, braided PE third layer and grey outer layer with 22mm pushfit end connections.
Marking:
Salamander logo on top cover. Salamander logo, maximum temperature, maximum pressure, and product info on adhesive label on lid. Flow arrow on body.
Installation Requirements:
R001 R150 R415
Expiry date:
31/01/2027
Model:
EVE Whole House Booster Pump: EVETU (twin variant).
Product Images

Approval Holder:
Salamander Pumps
Company Name
Salamander Pumps
Postcode
SR5 3XE
Country
United Kingdom
Phone
0191 535 4528
General Email
lewisw@salamanderpumps.co.uk

View All Listings by this Company
Manufacturer:
Salamander Pumps
Company Name
Salamander Pumps
Postcode
SR5 3XE
Country
United Kingdom
Phone
0191 535 4528
General Email
lewisw@salamanderpumps.co.uk

View All Listings by this Company

Print This Approval


#2201060

Electronic water pump booster system with plastic body, plastic impeller and NBR ‘O’-rings. The system can be installed vertically or horizontally. The inlet incorporates a non-return valve (not suitable for backflow protection). Maximum working pressure 7.5 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2201060
Size:
1” BSP (F)
Marking:
DAB on control face. DAB, CE, model, maximum temperature, and other technical information on adhesive label on body.
Installation Requirements:
R001 R008 R415
Expiry date:
31/01/2027
Model:
E.SYBOX MINI
Product Images

Approval Holder:
DAB PUMPS SPA
Company Name
DAB PUMPS SPA
Address
Via Marco Polo 14 Mestrino (PD)
Postcode
35035
Country
Italy
General Email
certifications@dwtgroup.com

View All Listings by this Company
Manufacturer:
DAB PUMPS SPA
Company Name
DAB PUMPS SPA
Address
Via Marco Polo 14 Mestrino (PD)
Postcode
35035
Country
Italy
General Email
certifications@dwtgroup.com

View All Listings by this Company

Print This Approval


#2112045

‘ECOCIRC XL N’ & ‘ECOCIRC XL PLUS N’ range of circulation pumps with stainless steel bodies, plastic impellers, and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2112045
Size:
1½”-2” BSP (M). DN32-65 flanged.
Marking:
Lowara (brand of Xylem) and Lowara logo, manufacturer name (xylem brand) and technical information on adhesive label on top of pump.
Installation Requirements:
R001
Expiry date:
31/12/2026
Model:
ECOCIRC-XL N X1-X2 X3 X4 & ECOCIRC-XL PLUS N X1-X2 X3 X4. Where: ECOCIRC XL = series name. PLUS = with communication capabilities. N = stainless steel. X1 = port nominal diameter in mm (25 or 32 threaded models, where 25 = 1½” BSP (M), 32 = 2” BSP (M), 32-65 on flanged models). X2 = maximum head in m x 10. X3 = maximum flow - low flow versions - ‘empty’ = standard version. X4 = flange type - F = flanged, ‘empty’ = threaded BSP (M). Examples: ECOCIRC-XL N 25-40 & ECOCIRC XL PLUS N 65-120F.
Product Images

Approval Holder:
Xylem Service Italia S.r.l
Company Name
Xylem Service Italia S.r.l
Address
Via Vittorio Lombardi 14, 36075 Montecchio Maggiore-Alte Ceccato VI, Vicenza
Country
Italy
Phone
0039 0444 707111

View All Listings by this Company
Manufacturer:
Xylem Service Hungary Kft.
Company Name
Xylem Service Hungary Kft.
Address
Külso-Kátai út. 41 HU-2700 Cegléd
Phone
+36-53-510502

View All Listings by this Company

Print This Approval


#2110066

Range of vertical multistage pumps with stainless-steel bodies, stainless-steel impellers, shaft and outer sleeve. Maximum working pressures: T (oval flange): 16.0 bar. V (Victaullic & grooved), C (clamp flanges) & F (round flange) versions: 26.0 bar. Maximum operating temperature 100°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2110066
Size:
EV1-EV3 & 1VR-3VR models - F (round flange) versions: DN25. EV6-EV20 & 6VR-20VR models - F (round flange) versions: DN32-50. EV1-EV20 & 1VR-20VR models - T (oval flange), V (Victaullic - EV; Grooved - VR), C (clamp flanges) & F (round flange) versions: DN32-50.
Marking:
Franklin Electric, model name, date of production (DD/MM/YYYY), pressure, temperature and other technical information on data plate on body.
Installation Requirements:
R001 R415
Expiry date:
31/10/2026
Model:
EV and VR ranges. Code example (EV range): EV 20 /15 A B C D E F G H J K L M N PMP/A. Where: EV = Pump model EV (EV = E-Tech “brand”). 20 = Rated flow [m³/h] (varies: 1-20). /15 = No. of stages/impellers. (See model and stages below for more detail). A = No. of trimmed impellers, if "Empty" = none. B = Flange type: "F" - round; "T" - oval; "V" - Victaulic; "C" - clamp. C = Materials: "I" - (AISI304/EN1.4301); "N" (AISI316/EN1.4401). D = Motor power (kW x 10). E = Frequency: "5" - 50Hz; "6" - 60Hz. F = No. of motor poles: "Empty" - 2 poles; "4" - 4 poles. G = Motor type: "Empty" - without motor, "T" - 3-phase; "M" - 1-phase. H = Mechanical Seal: "Empty" - standard version (EV1-EV20 & 1VR-20VR versions only). J = Type of mechanical Seal: E1 (SiC-Carbon Graphite-EPDM) or E2 (SiC-SiC-EPDM). K = "Empty" - standard version, "H" - high pressure. L = "Empty" - standard version, "P" - passivated. M = "Empty" - standard version N = "Empty" - no motor, “IE..” motor efficiency class. PMP/A = cold formed pump casing. Code example (VR range): 3 VR0700 A B C X-XXXX. Where: 3 = Rated flow [m³/h] (varies: 1-20). VR = Pump model (VR = FPS “brand”). 07 = No. of stages/impellers. (See model and stages below for more detail). 00 = Impeller trim: 00 = no trim, A1 = 1A (one trimmed impeller), A2 = 2A (two trimmed impellers). A = Materials: "H" - (AISI304/EN 1.4301); "N" (AISI316/EN 1.4401). B = Flange type: "F" - round; "T" - oval; "V" - Grooved (Victaullic); "C" - clamp. C = Mechanical Seal: “1” - QBE; “2” - QQE. X-XXXX = Combination of numbers and letter relating to frame, speed, motor and electronics (does not affect water pathways). Last two digits can be empty for versions without a motor. Minimum and maximum number of stages (please note the oval flange models have a lower maximum, this is included in brackets as follows [15] to denote 15 stages): EV1/1VR: stage from 2 to 37 [23] (50Hz) and from 2 to 25 [15] (60Hz); EV3/3VR: stage from 2 to 33 [21] (50Hz) and from 2 to 23 [14] (60Hz); EV6/6VR: stage from 2 to 36 [21] (50Hz) and from 2 to 23 [14] (60Hz); EV10/10VR: stage from 2 to 24 [15] (50Hz) and from 2 to 17 [10] (60Hz); EV15/15VR: stage from 1 to 17 [10] (50Hz) and from 1 to 12 [10] (60Hz); EV20/20VR: stage from 1 to 17 [10] (50Hz) and from 1 to 10 [7] (60Hz).
Product Images

Approval Holder:
Franklin Electric SRL
Company Name
Franklin Electric SRL
Address
Via Asolo 7 Dueville Vicenza 36031
Country
Italy
Phone
+39 0444 360366
General Email
info.it@fele.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 13 of 36

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.