Commercial clothes washing machine having a flexible inlet hose and solenoid valve with filter at the inlet supplying a Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Front loading, commercial washing machine. Flow is supplied via solenoid valves and the unit incorporates a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 10.0 bar. Maximum operating temperature 70°C.
Range of commercial conveyor type dishwashers with the flow controlled by a solenoid valve and discharged via three type AB air gaps (pre-wash, rinse and wash) (verified by test - suitable for backflow protection against fluid category 5). The products are supplied with a brass bodied ‘Y’-pattern strainer, brass adaptors ¾”x¾” (M)x(M) and (F)x(F) and dual layer PVC inlet hoes(s) (grey outer/black inner) and EPDM washers. The DR*11**** model has two solenoids and requires three inlet hoses and also includes a brass tee-piece to connect them ¾”x¾”x¾” (M). Maximum working pressure 6.0 bar. Maximum operating temperature 60ºC.
Range of water conditioners. The WFL38 model has a brass body, all other models are stainless steel. Operating parameters: GRANDER® Inline units - Maximum working pressure 10.0 bar. Maximum operating temperature 95°C. GRANDER® Flexible unit - Maximum working pressure 6.0 bar. Maximum operating temperature 75°C. GRANDER® Apartment unit & Immersion units - Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.
Range of ultraviolet disinfection units incorporating isolation valves and draw off tapes. Maximum working pressure 16.0 bar. Maximum operating temperature 50ºC.
Range of ultra-violet disinfection units consisting of a stainless-steel body and quartz tubes with EPDM O rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50.0°C
Range of under-counter or counter-top drinking water dispensers delivering still ambient, still chilled & sparkling water. HygienePlus®. Models incorporate a built-in filter system. The flow is controlled by a solenoid valve which is either operated by a touch or a touch pad. The water is dispensed via a tap arrangement on under-counter versions or an integrated outlet on counter-top versions. The inlets incorporate an approved check valve cartridge assembly however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 6.0 bar. Cold water use only.
Range of undercounter or deck mounted drinking water fountains which dispense ambient and/or chilled water. Flow is controlled via a solenoid valve and the products are activated via a push button or infa-red sensor . Maximum working pressure 7.0 bar. Cold water use only.
Range of inline water meter kits incorporating brass bodies, a spherical valve and drain off valve. Maximum working pressure 10.0 bar. Cold water use only.
‘Hostaform® C9021 ECO-B NATURAL, C9021, M15HP, C2521, C13021, C13031, C27021 ECO-B NATURAL, C27021, C52021 & M90JG’. Injection moulded, natural (which appear to be white) acetal materials available in the following colours: Black 14 DW (formerly known as Black 14), White 22, Grey 33, Grey 36, Grey 39, Red 46, Red 47, Yellow 56, Brown 65, Green 76, Blue 87, RAL 2010, RAL 4008 & RAL 5005. Customer specific colours may also be provided with a nomenclature following the structure ‘xx/yyyy DW’ where ‘yyyy’ denotes the specific colour shade, ‘DW’ denotes ‘Drinking Water’ & ‘xx’ denotes 10 – black, 20 - white (incl. Cream, 30 – grey, 40 – red (incl. Pink), 50 – yellow, 60 – brown (incl. Beige), 70 – Green & 80 – blue. For use with water up to 65°C.
Page 13 of 96
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.