Directory Search Results

Print List

#2310383

Range of water meters with blue epoxy power coated cast iron bodies, incorporating plastic turbines, NBR ‘O’-rings and gaskets. Maximum working pressure 16.0 bar. BS6920 50°C.

Section:
1505 Water Meters
Size:
DN50 - DN200 flanged
Marking:
GAER, model number and other technical info printed on dial face. Size and flow arrow on body.
Installation Requirements:
R001
Expiry date:
31/10/2028
Model:
GMW PLUS RANGE

Approval Holder:
Hidroglobal Tecnologia del Agua S.A.
Company Name
Hidroglobal Tecnologia del Agua S.A.
Address
C/ GARBÍ 3 Pol.Ind. Can Volart PARETS DEL VALLÈS
Postcode
08150
Country
Spain
Phone
+34 93 573 74 00
General Email
acalderon@regaber.com

View All Listings by this Company

Print This Approval


#2310314

Pentobox range of water meter manifolds with plastic bodies and an integral spherical valve on the inlet. The models incorporate a non-return valve, (not suitable for backflow protection). Compression models are for use with metric and imperial PE80 pipe (manufactured to BS EN 12201). Maximum working pressure 16.0 bar. Cold water use only.

Section:
1510 Water Meter Manifolds
Size:
Please refer to model.
Marking:
AVK logo and date stamp on cover. Flow arrow on meter box body. Date stamp and size on manifold. (Date stamps = two clocks, one for month, the other for year).
Installation Requirements:
R001 R008
Expiry date:
31/10/2028
Model:
8054125521110301000: 25mm compression. 8054132521110301000: 32mm compression. 8054121521110301000: ½" compression. 8054326521110301000: ¾" BSP (F). 8054125521110331000: 25mm compression. 8054132521110331000: 32mm compression. 8054121521110331000: ½" compression. 8054326521110331000: ¾" BSP (F).
Product Images

Approval Holder:
AVK UK Ltd.
Company Name
AVK UK Ltd.
Address
8 Rushmills, Northampton, Northants.
Country
NN4 7YB

View All Listings by this Company

Print This Approval


#2310302

Waste water heat recovery unit having with an internal copper tube which provides a double wall separation between the waste water and cold mains supply. Maximum working pressure 10 bar. Maximum operating temperature 50°C

Section:
1530 Miscellaneous Fittings
Size:
½” BSP(M)
Marking:
Recoup, Easyfit, Wras on body.
Installation Requirements:
R001
Expiry date:
31/10/2028
Model:
R-EZ-01 Easyfit+
Product Images

Approval Holder:
Recoup Energy Solutions Ltd.
Company Name
Recoup Energy Solutions Ltd.
Address
Trumpeter House Trumpeter Rise Long Stratton
Postcode
NR15 2DY
Country
United Kingdom
Phone
+441379844010
General Email
ian.steward@recoup.co.uk

View All Listings by this Company
Manufacturer:
Recoup Energy Solutions Ltd.
Company Name
Recoup Energy Solutions Ltd.
Address
Trumpeter House Trumpeter Rise Long Stratton
Postcode
NR15 2DY
Country
United Kingdom
Phone
+441379844010
General Email
ian.steward@recoup.co.uk

View All Listings by this Company

Print This Approval


#2310315

Hydraulic circuit used to control the water path within the heating and sanitary boiler, with plastic body incorporating filter, flow regulator, plate heat exchanger and EPDM O-rings. Maximum working pressure 7.0 bar. Maximum operating temperature 85°C.

Section:
1530 Miscellaneous Fittings
Size:
¾”BSP(M) x ½”BSP(M).
Marking:
Company logo on body (CHUNHUi)
Installation Requirements:
R001 R008
Expiry date:
31/10/2028
Model:
FUSION ASTRO- Engineering Plastics Hydraulic Circuit.
Product Images

Approval Holder:
THE ELECTRIC HEATING COMPANY LTD
Company Name
THE ELECTRIC HEATING COMPANY LTD
Address
Block 5, Unit 40 Third Road Blantyre Ind Est GLASGOW
Postcode
G72 0UP
Country
United Kingdom
Phone
07986970466
General Email
chris@electric-heatingcompany.co.uk

View All Listings by this Company
Manufacturer:
Zhejiang Chunhui Intelligent Control Co Ltd
Company Name
Zhejiang Chunhui Intelligent Control Co Ltd
Address
No. 288 Chunhui Industrial Rd. Shangyu, Zhejiang
Country
China
General Email

View All Listings by this Company

Print This Approval


#2310332

Range of flow sensors with or without brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.

Section:
1530 Miscellaneous Fittings
Size:
See models
Marking:
With body: Sika logo, flow arrow moulded on body; Sika logo, model number, pressure, flow arrow and other tech info on label on cable. Internal turbine without body: Sika logo, model number, date of manufacture (WWYY) and flow arrow on body.
Installation Requirements:
R001
Expiry date:
31/10/2028
Model:
Range of flow sensors with brass bodies, Type series VTY20 VY2061abcdefgh Flow sensor for DN20 VY2061MAHNefA5 Flow sensor with brass turbine body (CW617N-DW) 1”BSP(M) VY2061K50000YY Only internal turbine system without turbine body Models VY2061abcdefgh with ab: for body material (MA = Brass CW617N-DW, K5 = without turbine body, only the internal turbine system), with cd: for sensor and signal output (HN = Hall sensor NPN, 00 = without sensor), with ef: for electrical cable connection (various – in combination can be 00…99 or AA…ZZ, examples 05 = 500 mm, X1 = 80 mm with Molex plug connector), with gh: for process connection (A5 = G1 male thread - nominal size DN20, YY = without – only possible with ab = K5). Models VY2061abyyyyyzz with ab: for body material (MA = Brass CW617N-DW, K5 = without turbine body, only the internal turbine system), with yyyyy: for name of customer (5 digits), with zz: for consecutive number (2 digits, 01…99). Note: Models VY2061abyyyyyzz are customized versions CW724R brass version added June 2024.
Product Images

Approval Holder:
SIKA Systemtechnik GmbH
Company Name
SIKA Systemtechnik GmbH
Address
Struthweg 7-9 Kaufungen
Postcode
34260
Country
Germany
Phone
+49 5605 803 652
General Email
grass@sika.net

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1184 of 2316

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.