Single hole, single outlet (fixed) electronically controlled combination tap assemblies (chromium plated). The flow is controlled by a solenoid valve activated via an infra-red sensor. Spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of single hole, single outlet (fixed) electronically controlled combination tap assemblies (various finishes). Flow is controlled by a solenoid valve activated by via an infra-red sensor and the temperature set via a manual lever. The inlet adaptor to the hoses incorporates a check valve cartridge verified by test (suitable for backflow protection against Fluid Category 2 or 3) with a built-in strainer, and the outlet incorporates an aerator. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of single hole, single outlet, electronically controlled tap assemblies (chrome plated brass body). The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Supplied with a stainless steel braided PEX lined flexible connection hose and a manual lever for controlling the temperature. Maximum working pressure 8.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of inlet control valves with DZR brass bodies incorporating a pressure reducing valve (set at 1.5, 1.8. 2.0, 2.1, 3.0 or 3.5 depending on model) and a pressure relief valve (set at 3.0, 3.5, 4.5, 5.0. 6.0 or 8.0 depending on model. All models incorporate a stainless-steel mesh and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Model CWIC355040 comes supplied with a tundish. For use with copper pipe to BS EN 1057, PB pipe (with inserts) to BS EN 7291-2:2010 and PEX pipe (with inserts) to BS EN 7291-3:2010. Maximum working pressure 16.0. Maximum operating temperature of 25°C.
WC flushing cistern incorporating a side entry BS 1212-4 compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern is operated by a manual push button and incorporates a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
Page 1142 of 2219
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.