Deck mounted, single hole, single outlet (fixed) electronically controlled tap assembly with stainless steel body. The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.
Range of wall mounted, two hole, single outlet (fixed) battery controlled tap assemblies (chromium plated brass) incorporating approved check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection .The flow is controlled via a solenoid valve activated via an infra-red sensor. The inlet to the solenoid incorporates a stainless-steel strainer. The tap is supplied with spherical valves for both hot and cold inlets. The spout outlet incorporates a plastic aerator. Maximum working pressure 5.0 bar. Maximum operating temperature 65°C.
Concealed WC dual flushing cistern with a BS 1212-4 (2016) float operated inlet valve providing a Type AG air gap arrangement and a dual flush outlet valve. The flush volume is operated by a two push button assembly for a 6 or 3 litre flush volume. Incorporating a servicing valve on the inlet supply. Maximum working pressure 10.0 bar. Cold water use only.
WC flushing cistern incorporating a side entry BS1212-4 (2016) compact type float operated inlet valve providing a Type AG air gap with a dual flush drop valve for full flush volumes of up to 5.5 litres and a reduced flush of up to 2.7 litres and incorporates a servicing valve and flexible hose on the inlet supply. The cistern is operated by a manually operated push button. Maximum working pressure 10.0 bar. Cold water use only.
Range of in-line, non-verifiable single check valve assemblies with DZR brass bodies and spring loaded, resilient trim check valve cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC
Range of Caprice assisted baths which include a choice of with or without a hoist. Flow is controlled via a thermostatic mixing valve supplying the bath spout outlet or shower handset. The discharge from the bath spout and shower handset in via a type AUK 3 airgap, verified by measurement, suitable for Fluid Category 5 backflow protection Maximum working pressure 6.0 bar.
Non-metallic materials and components comply with BS6920 at 46°C
Range of ceramic disc diverter headworks with or without a on/off function, to be installed in specifically dimensioned bores. Maximum working pressure 12.0 bar. Maximum operating temperature 85°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with either a single lever or dome type operating member (see model). The spout outlet incorporates a plastic aerator (specific models only - see model section). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet fixed combination tap assemblies, incorporating brass bodies (various finishes). Model A05406 has a non-rising spindle headwork with cross top operating members. All other models have a ceramic cartridge headwork with single lever operating member. The spout outlets incorporate a plastic aerator. Maximum operating pressure 5.0 bar. Maximum operating temperature 60°C.
Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headwork with a single lever operating member. The spout outlet is a waterfall type with or without a stainless-steel mesh (see model). Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Page 102 of 428
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.