Directory Search Results

Print List

#2111366

Range of cold water in tank booster sets incorporating an ‘AG’ air gap, consisting of a GRP water storage cistern incorporating a float operated inlet valve, with a copper float and submersible pump or pumps (depending on model). The products incorporate an externally mounted stainless-steel manifold with servicing valve(s), expansion vessel, pressure gauge and a digital control panel. The pumps are connected to the external components via a discharge assembly of internal pipework including an in-line non-verifiable single check valve assembly (suitable for backflow prevention of Fluid Category 2). Maximum working pressure 10.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2111366
Note:
These cisterns are not suitable for water for domestic purposes unless they are so modified and installed as to comply in all respects with Schedule 2. Section 7, Paragraph 4, of the Water Supply (Water Fittings) Regulations 1999. The products incorporate a Fluid Category 3 air gap arrangement.
Size:
1" BSP (M)
Marking:
Fluid Water, Stuart Turner or Flowtech, address, product ref, capacity, job ref and contact information on adhesive label on tank body. Fluid Water or Stuart Turner, model, year of manufacturer and serial no on control box.
Installation Requirements:
R001 R280 R415
Expiry date:
30/11/2026
Proviso:
If implemented, the overflow and warning pipe discharge to drain must be via a type `AA` `AB` or `AD` airgap in accordance with EN 1717.
Model:
IT-A-V-B-C-D-E-F-G-AG Where: IT = Product range name (In Tank). A = Number of pumps (1,2, or 3 pumps). V = Variable speed. B = Maximum flow (l/min per pump - 80 or 120l/min). C = Maximum head (m per Pump, e.g. 60). D = Controller type (MAB). E = Power input (T = 3 Phase – M = 1Phase). F = Vessel Capacity (8 = 8 litre, 24= 24 litre). G = Tank size (Nominal capacity in litres - 250-3000). AG = ‘AG’ air gap. Example: IT-3V-8060-MAB-M/24-1000-AG In Tank booster set with 3 pumps, variable speed, 80l/min max. flow and 60m max. head, MAB controller, 1 phase, 24 litre expansion vessel, 1000 litre capacity with an AG air gap. Model added October 2025: IN - A - B - C - D - E - F IN = Product range name A = number of pumps (1,2, or 3 pumps) B = Maximum flow (per pump) C = Maximum Head (per pump) D = Tank capacity E = Voltage F = Controller Type Example: IN3-8060-1000-M-MAB • IN = product range • A = 3 pumps • B = 80 l/min max flow • C = 60m max head • D = 1000L nominal capacity • E – 1 phase 230v • F = MAB control panel

Approval Holder:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Unit A, Quedgeley West Business Park, Hardwicke, Gloucester
Postcode
GL2 4PA
Country
United Kingdom
Phone
01452313334
General Email
austin.hill@dutypoint.com

View All Listings by this Company

Print This Approval


#2111367

Range of cold water in tank booster sets incorporating an ‘AB’ air gap, consisting of a GRP water storage cistern incorporating a float operated inlet valve, with a copper float and submersible pump or pumps (depending on model). The products incorporate an externally mounted stainless-steel manifold with servicing valve(s), expansion vessel, pressure gauge and a digital control panel. The pumps are connected to the external components via a discharge assembly of internal pipework including an in-line non-verifiable single check valve assembly (suitable for backflow prevention of Fluid Category 2). Maximum working pressure 10.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2111367
Note:
These cisterns are not suitable for water for domestic purposes unless they are so modified and installed as to comply in all respects with Schedule 2. Section 7, Paragraph 4, of the Water Supply (Water Fittings) Regulations 1999. The products incorporate a Fluid Category 5 air gap arrangement.
Size:
1" BSP (M)
Marking:
Fluid Water or Stuart Turner, address, product ref, capacity, job ref and contact information on adhesive label on tank body. Fluid Water or Stuart Turner, model, year of manufacturer and serial no on control box.
Installation Requirements:
R001 R280 R415
Expiry date:
30/11/2026
Proviso:
If implemented, the warning pipe discharge to drain must be via a type `AA` `AB` or `AD` airgap in accordance with EN 1717.
Model:
IT-A-V-B-C-D-E-F-G-AB Where: IT = Product range name (In Tank). A = Number of pumps (1,2, or 3 pumps). V = Variable speed. B = Maximum flow (l/min per pump - 80 or 120l/min). C = Maximum head (m per Pump, e.g. 60). D = Controller type (MAB). E = Power input (T = 3 Phase – M = 1Phase). F = Vessel Capacity (8 = 8 litre, 24= 24 litre). G = Tank size (Nominal capacity in litres - 250-3000). AB = ‘AB’ air gap. Example: IT-3V-8060-MAB-M/24-1000-AB In Tank booster set with 3 pumps, variable speed, 80l/min max. flow and 60m max. head, MAB controller, 1 phase, 24 litre expansion vessel, 1000 litre capacity with an AB air gap.

Approval Holder:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley-on-Thames Oxfordshire
Postcode
RG9 2AD
Country
United Kingdom
Phone
01491 572655
General Email
stuart.savill@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


#2301305

Range of water pressure booster sets with a cold water storage cistern and booster pump. All models incorporate a non-return valve, not suitable for backflow protection. These models have an AG air gap suitable for fluid category 3 protection. Maximum working pressure 6.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2301305
Size:
½” BSP (M).
Marking:
Adhesive label on top of cistern stating - Stuart Turner, Model No, Serial number, Part No, Volume in litres and technical information.
Installation Requirements:
R001 R415 R270 R280
Expiry date:
31/01/2028
Model:
46711 iBoost V200 with cold water storage cistern and variable speed pump. 46668 iBoost F200 with cold water storage cistern and fixed speed pump.

Approval Holder:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley-on-Thames Oxfordshire
Postcode
RG9 2AD
Country
United Kingdom
Phone
01491 572655
General Email
stuart.savill@stuart-turner.co.uk

View All Listings by this Company
Manufacturer:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley-on-Thames Oxfordshire
Postcode
RG9 2AD
Country
United Kingdom
Phone
01491 572655
General Email
stuart.savill@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


#2301357

Range of water pressure booster sets with a cold water storage cistern and booster pump. All models incorporate a non-return valve, not suitable for backflow protection. These models have an AB air gap suitable for fluid category 5 protection. Maximum working pressure 6.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2301357
Note:
R574 applies. The water in the storage cistern is considered wholesome.
Size:
½” BSP (M).
Marking:
Adhesive label on top of cistern stating - Stuart Turner, Model No, Serial number, Part No, Volume in litres and technical information.
Installation Requirements:
R001 R415 R270 R280 R570
Expiry date:
31/01/2028
Model:
46713 iBoost V200 CAT5 with cold water storage cistern and variable speed pump. 46677 iBoost F200 CAT5 with cold water storage cistern and fixed speed pump.

Approval Holder:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley-on-Thames Oxfordshire
Postcode
RG9 2AD
Country
United Kingdom
Phone
01491 572655
General Email
stuart.savill@stuart-turner.co.uk

View All Listings by this Company
Manufacturer:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley-on-Thames Oxfordshire
Postcode
RG9 2AD
Country
United Kingdom
Phone
01491 572655
General Email
stuart.savill@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


#250304718

Range of combined storage and booster sets, incorporating a cold-water storage cistern, submersible pump, solenoid valve or alternative actuated ball valve, non-return valve (not suitable for backflow protection), isolation valves and expansion vessel. Maximum working pressure 10.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
250304718
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1” BSP (F)
Marking:
Dutypoint, model & product info on label.
Installation Requirements:
R001 R415
Expiry date:
31/03/2030
Model:
Dutypoint Systems ScubaTANK range comprising of models: ‘ WX A BBBB CCC’ – where: ‘A’ denotes number of pumps and is replaced with 1 or 2. ‘BBBB’ denotes pump size and is replaced with 3040, 3060, 3080, 3100, 5040, 5060, 5080, 5100, 9040, 9060 or 9090. ‘CCC’ denotes size of storage cistern in litres and is replaced with 175, 300, 375, 440, 490, 490, 575, 650, 750, 800, 1050, 1250, 1650 or 2250.

Approval Holder:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Unit A, Quedgeley West Business Park, Hardwicke, Gloucester
Postcode
GL2 4PA
Country
United Kingdom
Phone
01452313334
General Email
austin.hill@dutypoint.com

View All Listings by this Company
Manufacturer:
Dutypoint Ltd.
Company Name
Dutypoint Ltd.
Address
Unit A, Quedgeley West Business Park, Hardwicke, Gloucester
Postcode
GL2 4PA
Country
United Kingdom
Phone
01452313334
General Email
austin.hill@dutypoint.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 11 of 41

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.