STROM LTD Approvals


#2009038

Pre-set pressure relief valve (set @ 3.0 bar) incorporating a brass body, NBR ‘O’-ring and an EPDM diaphragm. The valve is fitted with a hand operated rotating easing gear. Maximum operating temperature 90°C.

Section:
2210 Valves
Section Subtitle:
Pressure relief.
WRAS Approval Number:
2009038
Expiry date:
30/09/2025
Size:
½” BSP (M).
Marking:
Foshan City Suertai Electric Co. Ltd. logo (‘SET’, an abbreviation of Su Er Tai), thread size and flow arrow on body. Pressure rating on cap
Installation Requirements:
R001 R200
Model:
220010131.
Factor:
STROM LTD
Company Name
STROM LTD

View All Listings by this Company
Manufacturer:
Foshan City Suertai Electric Co. Ltd.
Company Name
Foshan City Suertai Electric Co. Ltd.

View All Listings by this Company

Print This Approval


#2012051

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system, incorporating a pressure relief valve set at 3.0 bar and expansion vessel on the primary circuit. The inlet of the replenishing valve between the primary and secondary circuits incorporate a plastic strainer. Maximum working pressure 2.5 bar (primary) and 6.0 bar (secondary). Maximum operating temperature 85˚C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2012051
Expiry date:
31/12/2025
Note:
Please note that the inlet pipework connects to the flow sensor, no fittings or valves prior to this are supplied. Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with Schedule 2 paragraph 7 of the Water Supply (Water Fittings) Regulations 1999.
Size:
½” BSP (M) inlet and outlet Secondary Circuit. ½” BSP (M) replenishing valve. ¾” BSP(M) inlet and outlet primary circuit.
Marking:
Strom on front of body. Model and technical info on adhesive label on side of body.
Installation Requirements:
R001 R140 R360
Model:
Strom E range comprising of models: SBSP7C, SBSP11C & SBSP15C. SBTP18C, SBTP21C & SBTP24C. The number in model indicates kW rating.
Factor:
STROM LTD
Company Name
STROM LTD

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.