Delabie Ltd. Approvals


#2104703

Range of single hole, single outlet, (fixed) combination tap assemblies (chromium plated brass), incorporating a ceramic cartridge headworks with a single lever operating member. The inlets incorporate plastic strainers and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlets of ‘2820’ incorporate a spherical valve. The spout outlets incorporate a plastic flow straightener and the products are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2104703
Expiry date:
30/04/2026
Note:
No testing preformed on the pop-up waste.
Size:
Stainless steel braided PEX lined flexible hose assemblies (with or without a spherical valve) incorporating a 3/8” BSP captive nut.
Marking:
Delabie on operating member.
Installation Requirements:
R001 R006 R009 R010
Model:
Securitherm 2720LEP, 2820LEP, 2720TEP & 2820TEP
Factor:
Delabie Ltd.
Company Name
Delabie Ltd.
Address
1-3 Henderson House Hithercroft Road Wallingford
Postcode
OX10 9DG
Phone
+44 1491 824 449

View All Listings by this Company
Manufacturer:
Delabie SAS
Company Name
Delabie SAS
Address
18 Rue Du Marechal Foch 80130 Friville Escarbotin France

View All Listings by this Company

Print This Approval


#2104704

Range of single hole, single outlet (fixed) combination tap assemblies (chromium plated brass), incorporating ceramic cartridge headworks with a single lever operating member. The inlets of model 2820 incorporates a flow restrictor and spherical valves. The spout outlets incorporate a plastic flow straightener and the products are supplied with a pop-up waste. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2104704
Expiry date:
30/04/2026
Note:
No testing has been performed on the pop-up waste.
Size:
stainless steel braided PEX lined flexible hose assemblies with ½” captive nuts or BSP (F) end connections.
Marking:
Delabie on operating member.
Installation Requirements:
R001 R006 R009 R010
Model:
2720T, 2720L, 2820T & 2820L
Factor:
Delabie Ltd.
Company Name
Delabie Ltd.
Address
1-3 Henderson House Hithercroft Road Wallingford
Postcode
OX10 9DG
Phone
+44 1491 824 449

View All Listings by this Company
Manufacturer:
Delabie SAS
Company Name
Delabie SAS
Address
18 Rue Du Marechal Foch 80130 Friville Escarbotin France

View All Listings by this Company

Print This Approval


#2108701

Range of self-closing tap assemblies (chrome plated brass) with spring loaded headworks and dome type or single lever (745440 model only) operating members. The spout outlet incorporates a plastic flow straightener. The product is supplied with plastic backnuts. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.

Section:
1820 Taps
Section Subtitle:
Self closing, metal.
WRAS Approval Number:
2108701
Expiry date:
31/08/2026
Size:
½” BSP (M)
Marking:
DELABIE on operating member
Installation Requirements:
R001 R006
Model:
745100, 745101, 745440, 745300, 745301.
Factor:
Delabie Ltd.
Company Name
Delabie Ltd.
Address
1-3 Henderson House Hithercroft Road Wallingford
Postcode
OX10 9DG
Phone
+44 1491 824 449

View All Listings by this Company
Manufacturer:
Delabie SAS
Company Name
Delabie SAS
Address
18 Rue Du Marechal Foch 80130 Friville Escarbotin France

View All Listings by this Company

Print This Approval


#2107082

Range of wall mounted, self-closing tap assemblies (chrome plated brass) with spring loaded headwork and dome type operating members. The spout outlet incorporates a plastic flow straightener. Maximum working pressure 5.0 Bar. Maximum operating temperature 60°C.

Section:
1820 Taps
Section Subtitle:
Self closing, metal.
WRAS Approval Number:
2107082
Expiry date:
31/07/2026
Size:
½” BSP (M)
Marking:
DELABIE on operating member
Installation Requirements:
R001 R040
Model:
746000, 746001.
Factor:
Delabie Ltd.
Company Name
Delabie Ltd.
Address
1-3 Henderson House Hithercroft Road Wallingford
Postcode
OX10 9DG
Phone
+44 1491 824 449

View All Listings by this Company
Manufacturer:
Delabie SAS
Company Name
Delabie SAS
Address
18 Rue Du Marechal Foch 80130 Friville Escarbotin France

View All Listings by this Company

Print This Approval


#2109034

Range of single hole, single outlet (fixed) combination tap assemblies incorporating chromium plated brass bodies, ceramic cartridge headwork with single lever operating member. The spout outlets incorporate either a plastic aerator or flow straightener. The 2565T1EP, 2565T3EP & 3565T5EP models are supplied with a check valve cartridge and filter on the inlets, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The 2565T1, 2565T3 & 2565T5 models have flow restrictors on the inlets. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.

Section:
0450 Combination Tap Assemblies
Section Subtitle:
Single hole, metal single outlet, fixed. Taps used in high risk installations, such as kitchen sinks, are considered to be a fluid category 5 risk. Backflow protection is usually provided in the form of an AUK3 tap gap. Where an AUK3 tap gap cannot be maintained, for example where the tap gap is compromised as a result of: • the tap being lowered in any way; • adjustment to the spout which reduces the distance between the tap outlet and spillover level of the sink; • or the operation of a pull out hose attachment; alternative fluid category 5 backflow protection is required.
WRAS Approval Number:
2109034
Expiry date:
30/09/2026
Marking:
Delabie on operating member.
Installation Requirements:
R001 R006 R009 R010
Model:
2565T1, 2565T3 & 2565T5. 2565T1EP, 2565T3EP & 2565T5EP.
Factor:
Delabie Ltd.
Company Name
Delabie Ltd.
Address
1-3 Henderson House Hithercroft Road Wallingford
Postcode
OX10 9DG
Phone
+44 1491 824 449

View All Listings by this Company
Manufacturer:
Delabie SAS
Company Name
Delabie SAS
Address
18 Rue Du Marechal Foch 80130 Friville Escarbotin France

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 4 of 10

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.