Stuart Turner Ltd Approvals


#2106806

Multistage, vertical booster pumps with a brass body and stainless steel pump housing, stainless steel impellers and EPDM ‘O’-rings. The 41782 (MV90 4M VSD) model includes a pressure transducer. Maximum working pressure 6.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2106806
Expiry date:
30/06/2026
Size:
38mm internal diameter.
Marking:
Stuart Turner, model no., part no., serial no. (incorporating date of manufacture S/N YYWW XXX-ZZZ, where XXX-ZZZ are replaced by numbers to denote order no. (XXX) and batch no. (ZZZ)) on adhesive label on pump motor body.
Installation Requirements:
R001 R415
Model:
41680 (MV90 4M). 41782 (MV90 4M VSD).
Factor:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley on Thames Oxon
Postcode
RG9 2AD
Phone
01491 572655
General Email
pumps@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


#2105321

‘Showermate Universal’ range of booster pumps with plastic bodies and impellers, stainless steel shafts, brass manifolds, NBR ‘O’-rings and EPDM seals. The product incorporates a pressure vessel. The outlet(s) incorporate(s) an approved single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection The inlet hose(s) supplied with this product incorporate(s) an isolation valve. Maximum working pressure 4.0 bar. Maximum operating temperature 65°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2105321
Expiry date:
31/05/2026
Note:
IRN R150 applies to both inlets of the Twin models only.
Size:
Stainless-steel braided EPDM lined flexible hoses with 15mm pushfit (inlet and outlets) x ¾” BSP captive nut end connections (to pump).
Marking:
Stuart Turner, model name, part no., serial number including date of manufacture (YYWW000-000, where 000-000 changes numerically to denote serial number) & other technical information on adhesive label on pump body. Showermate on pump body.
Installation Requirements:
R001 R150 R415
Model:
47375: Showermate U2.6 bar Single. 47376: Showermate U2.0 bar Twin. 47377: Showermate U2.6 bar Twin. 44921: Showermate U2.6 bar Single. 44918: Showermate U2.0 bar Twin. 44922: Showermate U2.6 bar Twin.
Factor:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley on Thames Oxon
Postcode
RG9 2AD
Phone
01491 572655
General Email
pumps@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


#2111050

Monobloc assembly with a DZR brass body comprising of a stainless steel strainer, adjustable pressure reducing valve and two approved check valve cartridges, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The product is supplied with two loose pressure gauges. For use with copper pipe (manufactured to EN1057). The product is also supplied with Maximum inlet supply pressure 6.0 bar. Maximum outlet pressure 0.8 bar to 6.0 bar. Maximum operating temperature 35°C.

Section:
2200 Valves
Section Subtitle:
Pressure reducing.
WRAS Approval Number:
2111050
Expiry date:
30/11/2026
Size:
28mm compression fitting with a 22mm compression adaptor
Marking:
STUART TURNER Logo, CR and flow arrow on body.
Installation Requirements:
R001
Model:
21104 Mainsboost Monobloc 22mm/28mm c/w gauges.
Factor:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley on Thames Oxon
Postcode
RG9 2AD
Phone
01491 572655
General Email
pumps@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


#2203051

Range of multistage pumps with brass suction and discharge bodies, stainless steel housing, shaft and impeller, and EPDM ‘O’-rings and seals. Maximum working pressure: 6.0 bar (41491 & 41492 models) or 9.0 bar (41493 & 41494 models). Maximum operating temperature 65°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2203051
Expiry date:
31/03/2027
Size:
1¼” BSP (F) inlet x 1" BSP (F) outlet
Marking:
STUART TURNER, model number, maximum pressure and temperature and other technical information on adhesive label on body.
Installation Requirements:
R001 R415
Model:
41491 - Multistage Pump 30, 41492 - Multistage Pump 40, 41493 - Multistage Pump 50, 41494 - Multistage Pump 60.
Factor:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley on Thames Oxon
Postcode
RG9 2AD
Phone
01491 572655
General Email
pumps@stuart-turner.co.uk

View All Listings by this Company
Manufacturer:
Fujian Fuan Wendy Electrical Machinery Co Ltd
Company Name
Fujian Fuan Wendy Electrical Machinery Co Ltd
Address
Qinxiyang Industrial Zone Fuan Fujian
General Email

View All Listings by this Company

Print This Approval


#2203054

Range of multistage pumps with brass suction and discharge bodies, stainless steel housing, shaft and impeller, and EPDM ‘O’-rings and seals. Maximum working pressure: 6.0 bar (46553 - Stuart CH 4-30 & 46554 - Stuart CH 4-40 models) or 9.0 bar (46555 - Stuart CH 4-50 &46556 - Stuart CH 4-60 models). Maximum operating temperature 65°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2203054
Expiry date:
31/03/2027
Size:
1¼” BSP (F) inlet x 1" BSP (F) outlet
Marking:
STUART TURNER, model number, maximum pressure and temperature and other technical information on adhesive label on body.
Installation Requirements:
R001 R415
Model:
46553 - Stuart CH 4-30 46554 - Stuart CH 4-40 46555 - Stuart CH 4-50 46556 - Stuart CH 4-60
Factor:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley on Thames Oxon
Postcode
RG9 2AD
Phone
01491 572655
General Email
pumps@stuart-turner.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2 of 5

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.