Stuart Turner Ltd Approvals


#2204353

Range of booster pumps with stainless steel bodies, plastic impellers, and NBR ‘O’-rings. The products incorporate a temperature sensor, pressure sensor, pressure vessel and a non-return valve integral to the pump chamber. Maximum working pressure 6.5 bar. Maximum operating temperature 75°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2204353
Expiry date:
30/04/2027
Size:
1” BSP (F)
Marking:
Stuart Turner and model number other technical information on adhesive label on body. Model on body
Installation Requirements:
R001 R415
Model:
VariQ Water Booster Pumps Rated Head: VariQ Part No. 47500 (370W), 25m VariQ Part No. 47498 (550W), 24m VariQ Part No. 47322, (750W), 30m VariQ Part No. 47499 (550W), 22m VariQ Part No. 47497 (750W), 28m VariQ Part No. 47501 (850W), 65m Addition to range February 2023: VariQ Part No. 47510, (750W), 30m
Factor:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley on Thames Oxon
Postcode
RG9 2AD
Phone
01491 572655
General Email
pumps@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


#2205308

Range of single and twin line shower booster pumps with plastic bodies, plastic impellors, stainless steel motor, NBR ‘O’-rings and EPDM seals. Each suction port incorporates a combined EPDM washer and stainless steel strainer. Maximum working pressure 3.0 bar. Maximum operating temperature 65°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2205308
Expiry date:
31/05/2027
Size:
Stainless-steel braided EPDM lined flexible hose assemblies with 15mm pushfit (inlet and outlets) x ¾” BSP captive nut end connections (to pump).
Marking:
Stuart Turner, Stuart turner logo, serial number and other technical information on advesvie label on body.
Installation Requirements:
R001 R415
Model:
Showermate TP S1.5 bar Twin (49084), Suregraft By Stuart Turner S1.5 bar twin (44837), Techflo TP S1.5 bar Twin (49087), Showermate TP S2.0 bar Twin (49085), Suregraft By Stuart Turner S2.0 bar twin (44838), Techflo TP S2.0 bar Twin (49088), Showermate TP S2.0 bar Single (49086), Techflo TP S2.0 bar Single (49089).
Manufacturer:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley on Thames Oxon
Postcode
RG9 2AD
Phone
01491 572655

View All Listings by this Company

Print This Approval


#2104076

Range of horizontal self-priming multistage pumps with stainless steel bodies, stainless steel impellers, shaft and outer sleeve. Maximum working pressure 10.0 Bar Maximum operating temperatures: EH Three phase models 85°C, EH Single phase models 55.0°C and EHsp models 35°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2104076
Expiry date:
30/04/2026
Size:
1 ¼” BSP (F) – 2” BSP (F)
Marking:
Stuart Turner, model number and other technical info on adhesive label on body.
Installation Requirements:
R001 R415
Model:
HM 0302 230 M 50 HM 0303 230 M 50 HM 0304 230 M 50 HM 0305 230 M 50 HM 0306 230 M 50 HM 0307 230 M 50 HM 0308 230 M 50 HM 0309 230 M 50 HM 0302 230-400 T 50 HM 0303 230-400 T 50 HM 0304 230-400 T 50 HM 0305 230-400 T 50 HM 0306 230-400 T 50 HM 0307 230-400 T 50 HM 0308 230-400 T 50 HM 0309 23 0-400 T 50 HM 0502 230 M 50 HM 0503 230 M 50 HM 0504 230 M 50 HM 0505 230 M 50 HM 0506 230 M 50 HM 0507 230 M 50 HM 0508 230 M 50 HM 0509 230 M 50 HM 0502 230-400 T 50 HM 0503 230-400 T 50 HM 0504 230-400 T 50 HM 0505 230-400 T 50 HM 0506 230-400 T 50 HM 0507 230-400 T 50 HM 0508 230-400 T 50 HM 0509 23 0-400 T 50 HM 0902 230 M 50 HM 0903 230 M 50 HM 0904 230 M 50 HM 0905 230 M 50 HM 0906 230 M 50 HM 0907 230 M 50 HM 0902 230-400 T 50 HM 0903 230-400 T 50 HM 0904 230-400 T 50 HM 0905 230-400 T 50 HM 0906 230-400 T 50 HM 0907 230-400 T 50 HM 0908 23 0-400 T 50 HM 1502 230 M 50 HM 1503 230 M 50 HM 1502 230-400 T 50 HM 1503 230-400 T 50 HM 1504 230-400 T 50 HM 1505 230-400 T 50 HM 1506 230-400 T 50 HM 1507 23 0-400 T 50 HM 2002 230 M 50 HM 2002 230-400 T 50 HM 2003 230-400 T 50 HM 2004 230-400 T 50 HM 2005 230-400 T 50 Type code: HM XY Z L 50 HM: product name X: flow rate Y: number of impellers Z: motor voltage L: motor phase M=single phase; T=three phase 50: frequency
Factor:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley on Thames Oxon
Postcode
RG9 2AD
Phone
01491 572655
General Email
pumps@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


#2205095

Range of vertical multistage booster pumps, with stainless steel bodies and impellors. Maximum working pressure: See models Maximum working temperature 85°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2205095
Expiry date:
31/05/2027
Size:
See Models
Marking:
Stuart Turner, CE, Max Temperature and other Technical info on Data Plates
Installation Requirements:
R001 R415
Model:
VM(.) 1 >> Size from 2 to 39 stages VM(.) 3 >> Size from 2 to 33 stages VM(.) 5 >> Size from 2 to 27 stages VM(.) 10 >> Size from 2 to 23 stages VM(.) 15 >> Size from 1 to 17 stages VM(.) 20 >> Size from 1 to 16 stages VM(.) 32 >> Size from 1 to 14 stages VM(.) 45 >> Size from 1 to 13 stages VM(.) 64 >> Size from 1 to 8 stages VM(.) 90 >> Size from 1 to 6 stages ( ) = VM >> AISI304 Components (L) = VM >> AISI316L Components (K*) = VM>> AISI304 + PRESSURE SENSOR (LK*) = VM >> AISI316L + PRESSURE SENSOR *K1 = DANFOSS MBS1900 *K2 = DANFOSS DST P 140 *K3 =SCHNEIDER XMLP0xxBD21F VM(.) 1-3 >> Available with Oval flange G1, Round Flange DN25, Loose round flange DN25, Victaulic DN32 and Clamp Ø59 VM(.) 5 >> Available with Oval flange G1¼, Round Flange DN32, Loose round flange DN32, Victaulic DN32 and Clamp Ø59. VM(.) 10 >> Available with Oval flange G1½, Round Flange DN40, Loose round flange DN40, Victaulic DN50 and Clamp Ø87. VM(.) 15-20 >> Available with Oval flange G2, Round Flange DN50, Loose round flange DN50, Victaulic DN50 and Clamp Ø87. VM(.) 32 >> Available with Loose round flange DN65. VM(.) 45 >> Available with Loose round flange DN80. VM(.) 64-90 >> Available with Loose round flange DN100. Model Bar VM( )1 2 16 VM( )1 3 16 VM( )1 4 16 VM( )1 5 16 VM( )1 6 16 VM( )1 7 16 VM( )1 8 16 VM( )1 9 16 VM( )1 10 16 VM( )1 11 16 VM( )1 12 16 VM()1 13 16 VM(L)1 14 16 VM( )1 16 16 VM( )1 18 16 VM( )1 20 16 VM( )1 22 16 VM( )1 24 16 VM( )1 26 16 VM( )1 27 25 VM( )1 29 25 VM( )1 32 25 VM( )1 34 25 VM( )1( 37 25 VM( )1 39 25 VM( )3 2 16 VM( )3 3 16 VM( )3 4 16 VM( )3 5 16 VM( )3 6 16 VM( )3 7 16 VM( )3 8 16 VM( )3 9 16 VM( )3 10 16 VM( )3 11 16 VM( )3 12 16 VM( )3 13 16 VM( )3 14 16 VM( )3 15 16 VM( )3 16 16 VM( )3 17 16 VM( )3 19 16 VM( )3 21 16 VM( )3 23 25 VM( )3 25 25 VM( )3 27 25 VM( )3 29 25 VM( )3 31 25 VM( )3 33 25 VM( )5 2 16 VM( )5 3 16 VM( )5 4 16 VM( )5 5 16 VM( )5 6 16 VM( )5 7 16 VM( )5 8 16 VM( )5 9 16 VM( )5 10 16 VM( )5 11 16 VM( )5 12 16 VM( )5 13 16 VM( )5 14 16 VM( )5 15 16 VM( )5 17 16 VM( )5 19 25 VM( )5 20 25 VM( )5 23 25 VM( )5 25 25 VM( )5 27 25 VM( )10 2 16 VM( )10 3 16 VM( )10 4 16 VM( )10 5 16 VM( )10 6 16 VM( )10 7 16 VM( )10 8 16 VM( )10 9 16 VM( )10 10 16 VM( )10 11 16 VM( )10 12 16 VM( )10 14 16 VM( )10 15 16 VM( )10 16 25 VM( )10 18 25 VM( )10 19 25 VM( )10 21 25 VM(L)10 22 25 VM( )10 23 25 VM( )15 1 16 VM( )15 2 16 VM( )15 3 16 VM( )15 4 16 VM( )15 5 16 VM( )15 6 16 VM( )15 7 16 VM( )15 8 16 VM( )15 9 16 VM( )15 10 16 VM( )15 11 16 VM( )15 12 25 VM( )15 13 25 VM( )15 15 25 VM( )15 17 25 VM()20 1 16 VM( L)20 2 16 VM( )20 3 16 VM( )20 4 16 VM( )20 5 16 VM( )20 6 16 VM( )20 7 16 VM( )20 8 16 VM( )20 9 16 VM( )20 10 25 VM( )20 11 25 VM( )20 12 25 VM( )20 13 25 VM( )20 14 25 VM( )20 15 25 VM( )20 16 25 VM( )32 1-1 16EVMS( )32 1-0 16 VM( )32 2-2 16 VM( )32 2-0 16 VM( )32 3-2 16 VM( )32 3-0 16 VM( )32 4-2 16 VM( )32 4-0 16 VM( )32 5-2 16 VM( )32 5-0 16 VM( )32 6-2 16 VM( )32 6-0 16 VM( )32 7-2 16 VM( )32 7-0 16 VM( )32 8-2 25 VM( )32 8-0 25 VM( )32 9-2 25 VM( )32 9-1 25 VM( )32 10-2 25 VM( )32 10-0 25 VM( )32 11-2 25 VM( )32 11-1 25 VM(L)32 12-2 30 VM(L)32 12-0 30 VM( )32 13-2 30 VM( )32 13-0 30 VM( )32 14-2 30 VM( )32 14-0 30 VM( )45 1-1 16 VM( )45 1-0 16 VM( )45 2-2 16 VM( )45 2-0 16 VM( )45 3-2 16 VM( )45 3-0 16 VM( )45 4-2 16 VM( )45 4-0 16 VM( )45 5-2 16 VM( )45 5-0 16 VM( )45 6-2 25 VM( )45 6-0 25 VM( )45 7-2 25 VM( )45 7-0 25 VM( )45 8-2 25 VM( )45 8-0 25 VM( )45 9-2 25 VM( )45 9-0 25 VM( )45 10-2 35 VM( )45 10-0 35 VM( )45 11-2 35 VM( )45 11-0 35 VM( )45 12-2 35 VM( )45 12-0 35 VM( )45 13-2 35 VM( )64 1-1 16 VM( )64 1-0 16 VM( )64 2-2 16 VM( )64 2-1 16 VM( )64 2-0 16 VM( )64 3-2 16 VM( )64 3-1 16 VM( )64 3-0 16 VM( )64 4-2 16 VM( )64 4-1 16 VM( )64 4-0 16 VM( )64 5-2 16 VM( )64 5-1 16 VM( )64 5-0 16 VM( )64 6-2 25 VM( )64 6-1 25 VM( )64 6-0 25 VM( )64 7-2 25 VM( )64 7-1 25 VM( )64 7-0 25 VM( )64 8-2 25 VM( )64 8-1 25 VM( )90 1-1 16 VM( )90 1-0 16 VM( )90 2-2 16 VM(L)90 2-0 16 VM(L)90 3-2 16 VM(L)90 3-0 16 VM(L)90 4-2 16 VM( )90 4-0 16 VM( )90 5-2 25 VM( )90 5-0 25 VM( )90 6-2 25 VM( )90 6-0 25
Factor:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley on Thames Oxon
Postcode
RG9 2AD
Phone
01491 572655
General Email
pumps@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


#2209057

Range of electrolytic water conditioning units consisting of stainless-steel tube with a copper/zinc alloy sacrificial anode and brass inlet and outlet connections. Compression models are for use with copper pipe (manufactured to BS EN 1057). Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.

Section:
2410 Water conditioners, de-scalers, phosphate dosing, magnetic, electrolytic and electronic
WRAS Approval Number:
2209057
Expiry date:
30/09/2027
Marking:
Stuart, product range name and flow arrow on adhesive label on body.
Installation Requirements:
R001 R120 R170
Model:
C3-22 44617, C23-45 44618 & C46-75 44619 STUART WATER CONDITIONERS 3/8” – 2” BSP male inlet/outlet & 10mm – 54mm compression.
Factor:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley on Thames Oxon
Postcode
RG9 2AD
Phone
01491 572655
General Email
pumps@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


#2211024

Range of water pressure booster pumps, comprising of a multi-stage pump with a brass body, and an expansion vessel. The product is supplied with a strainer and two stainless steel braided EPDM lined flexible hose assemblies. The outlet assembly incorporates a non-return valve, not suitable for backflow protection. Maximum working pressure models 46601 and 46602 6.0 bar, models 46622 and 46624 9.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2211024
Expiry date:
30/11/2027
Size:
1” BSP (F) (to strainer).
Marking:
STUART TURNER, CE, model number, maximum temperature, maximum pressure and other technical Info on adhesive label on pump.
Installation Requirements:
R001 R415
Model:
46601: Stuart CH 4-30 PS, 46602: Stuart CH 4-40 PS, 44622: Stuart CH 4-50 PS, 44624: Stuart CH 4-60 PS.
Manufacturer:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley on Thames Oxon
Postcode
RG9 2AD
Phone
01491 572655

View All Listings by this Company

Print This Approval


#2211047

Range of centrifugal multi-stage horizontal pressure booster pumps with brass bodies. The 46593, 46594, 46595 and 46610 models include a non-return valve (not suitable for backflow protection) and an expansion vessel. They are also supplied inline strainer and two stainless steel braided EPDM lined flexible hose assemblies with 1” captive nut x 1" BSP (M) end connection for the inlet and outlet. Maximum working pressure models 46578, 46596, 46605 and 46606: 6.0 bar, Models 46593, 46594, 46595 and 46610: 9.0 bar. Maximum operating temperature 65°C

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2211047
Expiry date:
30/11/2027
Size:
46578, 46596, 46605 and 46606 models: 1” BSP (F). 46593, 46594, 46595 and 46610 models: 1” BSP (F) (to strainer).
Marking:
Stuart Turner and Stuart Turner logo on adhesive label on body
Installation Requirements:
R001 R415
Model:
46578: Stuart CH 4-30 FL, 46596: Stuart CH 4-40 FL, 46605: Stuart CH 4-50 FL, 46606: Stuart CH 4-60 FL. 46593: Stuart CH 4-30 B (with hoses), 46594: Stuart CH 4-40 B (with hoses), 46595: Stuart CH 4-50 B (with hoses), 46610: Stuart CH 4-60 B (with hoses).
Manufacturer:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley on Thames Oxon
Postcode
RG9 2AD
Phone
01491 572655

View All Listings by this Company

Print This Approval


#2301306

Range of one piece water storage cisterns with a screened breather and over flow. Model 46714 iBoost+200 has a rectangular weir overflow Model 46712 iBoost+200 has a circular overflow Cold water only.

Section:
0120 Cisterns Storing Water for Domestic Purposes
Section Subtitle:
Drinking, washing, cooking and sanitary. Cisterns in this section comprise units, which, where detailed, include all the essential items identified in Schedule 2. Paragraph 16(4), of the Water Supply (Water Fittings) Regulations 1999. Where these items are not detailed in the directory entry, these will need to be included at point of installation, in order to fully comply with Schedule 2. Paragraph 16(4), of the Water Supply (Water Fittings) Regulations 1999.
WRAS Approval Number:
2301306
Expiry date:
31/01/2028
Note:
R574 applies to CAT5 models. The water in the storage cistern is considered wholesome.
Size:
½” BSP (M).
Marking:
Adhesive label on body – Stuart Turner, model, part No, capacity and other technical information.
Installation Requirements:
R001 R270 R280 R574
Model:
46714 iBoost+200 CAT5 Cold water storage cistern with rectangular weir overflow 46712 iBoost+200 Cold water storage cistern.
Manufacturer:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley on Thames Oxon
Postcode
RG9 2AD
Phone
01491 572655

View All Listings by this Company

Print This Approval


#2301305

Range of water pressure booster sets with a cold water storage cistern and booster pump. All models incorporate a non-return valve, not suitable for backflow protection. These models have an AG air gap suitable for fluid category 3 protection. Maximum working pressure 6.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2301305
Expiry date:
31/01/2028
Size:
½” BSP (M).
Marking:
Adhesive label on top of cistern stating - Stuart Turner, Model No, Serial number, Part No, Volume in litres and technical information.
Installation Requirements:
R001 R415 R270 R280
Model:
46711 iBoost V200 with cold water storage cistern and variable speed pump. 46668 iBoost F200 with cold water storage cistern and fixed speed pump.
Manufacturer:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley on Thames Oxon
Postcode
RG9 2AD
Phone
01491 572655

View All Listings by this Company

Print This Approval


#2301357

Range of water pressure booster sets with a cold water storage cistern and booster pump. All models incorporate a non-return valve, not suitable for backflow protection. These models have an AB air gap suitable for fluid category 5 protection. Maximum working pressure 6.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2301357
Expiry date:
31/01/2028
Note:
R574 applies. The water in the storage cistern is considered wholesome.
Size:
½” BSP (M).
Marking:
Adhesive label on top of cistern stating - Stuart Turner, Model No, Serial number, Part No, Volume in litres and technical information.
Installation Requirements:
R001 R415 R270 R280 R570
Model:
46713 iBoost V200 CAT5 with cold water storage cistern and variable speed pump. 46677 iBoost F200 CAT5 with cold water storage cistern and fixed speed pump.
Manufacturer:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley on Thames Oxon
Postcode
RG9 2AD
Phone
01491 572655

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2 of 3

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.