Ideal Boilers Ltd Approvals


#2305339

Range of vertical cased and insulated direct and indirect unvented stainless steel hot water storage cylinders. Fitted with a Caleffi 309463 GLD temperature and pressure relief valve sat at 6 bar & 90°C, and supplied with an inlet control group consisting of in-line pressure reducing valve (Caleffi set at 3 bar) and pressure relief valve (Caleffi CWIC200055) set at 4.5 bar, and incorporates a stainless-steel mesh and an approved check valve cartridge (verified by test suitable for backflow protection against Fluid Category 2), expansion vessel and filling loop. Maximum working pressure 4.4 bar. Maximum operating temperature 99°C.

Section:
1890 Unvented Heating Apparatus
Size:
28mm compression.
Marking:
Manufacturers name, address, date of manufacturer, capacity, model no, serial no, pressure and technical information.
Installation Requirements:
R001 R140 R360 R511 R530
Expiry date:
31/05/2028
Model:
IDEPLUHP150PPSZ & IDEPLUHP180PPSZ: 550mm diameter; 150, 180; litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired. Single zone. IDEPLUHP150PPSZSL & IDEPLUHP180PPSZSL: 475mm diameter; 150, 180, litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; single zone. IDEPLUHP210PPDZ, IDEPLUHP250PPDZ & IDEPLUHP300PPDZ: 550mm diameter; 210, 250, 300 litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired. Two zone. IDEPLUHP210PPDZSL: 475mm diameter; 210 litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired. Two zone. IDEPLUHP180DUOPPSZ & IDEPLUHP210DUOPPSZ: 550mm diameter 180, 210, litre; single coil cylinders on top of a buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; single zone. IDEPLUHP250DUOPPSZ & IDEPLUHP300DUOPPSZ: 630mm diameter 250, 300 litre; single coil cylinders on top of a buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; single zone. IDEPLUHP180DUOPPDZ & IDEPLUHP210DUOPPDZ: 550mm diameter 180, 210, litre; single coil cylinders on top of a buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; two zone. IDEPLUHP250DUOPPDZ & IDEPLUHP300DUOPPDZ: 630mm diameter 250, 300 litre; single coil cylinders on top of a buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; two zone. IDEPLUHP400: 630mm diameter; 400 litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14 kW. IDEPLU090MB: 630mm diameter; 90 litre; buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; and any cylinder without a buffer.
Product Images

Approval Holder:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Hull East Yorkshire
Postcode
HU5 4JN
Phone
07775659359
General Email
ben.higinbotham@groupe-atlantic.co.uk

View All Listings by this Company

Print This Approval


#2204367

‘POD’ range of indirect and direct heat interface units providing space heating and instantaneous hot water. The heat transfer is generated via plate heat exchangers. The domestic hot water (DHW) circuit incorporates an adjustable temperature mixing valve. The indirect models incorporate an expansion vessel (on the CW inlet of the DHW circuit) and a pressure relief valve set at 3.0 bar (on the space heating circuit). The indirect models only are supplied with a temporary filling loop, which comprises of a stainless steel braided EPDM lined flexible hose assembly and a lever operated spherical valve for connection to the primary circuit. The angled cold water inlet incorporates an isolation valve and a branch to connect to the filling loop, which includes a double check valve assembly (verified by test, suitable for backflow protection against Fluid Category 3). Maximum working pressure for indirect units: Primary circuit: 16.0 bar. Space heating: 2.5 bar. Secondary circuit (DHW): 10.0 bar. Maximum working pressure for direct units: Primary circuit: 10.0 bar. Space heating: 10.0 bar. Secondary circuit (DHW): 10.0 bar. Maximum operating temperature for domestic hot water 65°C. Maximum operating temperature for central heating and primary circuit 85°C.

Section:
1350 Heat Exchangers
Size:
22mm copper pipe connection.
Marking:
Ideal Heating badge and model on adhesive label on front casing. Manufacturer, serial number, model number, pressure rating and other technical information on data label within appliance.
Installation Requirements:
R001 R140 R360
Expiry date:
30/04/2027
Model:
POD i305LOR POD i405LOR POD i505LOR POD i605LOR POD i705LOR

Approval Holder:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Hull East Yorkshire
Postcode
HU5 4JN
Phone
07775659359
General Email
ben.higinbotham@groupe-atlantic.co.uk

View All Listings by this Company
Manufacturer:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Hull East Yorkshire
Postcode
HU5 4JN
Phone
07775659359
General Email
ben.higinbotham@groupe-atlantic.co.uk

View All Listings by this Company

Print This Approval


#2305361

Range of vertical cased and insulated direct and indirect unvented stainless steel hot water storage cylinders. Fitted with a Caleffi 309463 GLD temperature and pressure relief valve sat at 6 bar & 90°C, and supplied with an inlet control group consisting of in-line pressure reducing valve (Caleffi set at 3 bar) and pressure relief valve (Caleffi CWIC200055) set at 4.5 bar, and incorporates a stainless-steel mesh and an approved check valve cartridge (verified by test suitable for backflow protection against Fluid Category 2), expansion vessel and filling loop. Maximum working pressure 4.4 bar. Maximum operating temperature 99°C.

Section:
1890 Unvented Heating Apparatus
Size:
28mm compression.
Marking:
Ideal Heating, Manufacturers name, address, date of manufacturer, capacity, model no, serial no, pressure and technical information on adhesive label on body.
Installation Requirements:
R001 R140 R360 R511 R530
Expiry date:
31/05/2028
Model:
IDEPLUHP150DUOPPSZSL & IDEPLUHP180DUOPPSZSL. 475mm diameter 150, 180, litre; single coil cylinders on top of a buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; single zone

Approval Holder:
Ideal Boilers Ltd
Company Name
Ideal Boilers Ltd
Address
PO Box 103 National Avenue Hull East Yorkshire
Postcode
HU5 4JN
Phone
07775659359
General Email
ben.higinbotham@groupe-atlantic.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2 of 2

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.