Cistern - Flushing

Section Code 2034 : Incorporating Type AB air gap, providing fluid category 5 backflow protection. Suitable for use in a WC suite.

Back To Directory Sections

#2001903

Concealed BS EN 14055: 2010 WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) with a dual or single flush pneumatic drop valve capable of full flush volumes of up to 6 litres and a reduced flush of up to 4 litres. The cistern can be operated by touch free electronic or manual push button / push plate options. The supply hose incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2034 Cistern - Flushing
Section Subtitle:
Incorporating Type AB air gap, providing fluid category 5 backflow protection. Suitable for use in a WC suite.
WRAS Approval Number:
2001903
Expiry date:
31/01/2025
Size:
½” BSP Male or 15mm Push-fit Inlet connection.
Marking:
Top of outlet drop valve marked ‘TD’, Inlet valve discharge cap marked ‘HYDROFLO’. Front nut of inlet valve marked ‘DUDLEY BS 1212/4’.
Installation Requirements:
R001 R574
Model:
Vantage Concealed Cistern (Category 5).
Manufacturer:
Thomas Dudley Ltd
Company Name
Thomas Dudley Ltd
Address
Dauntless Works PO Box 28 New Birmingham Road
Postcode
DY1 4SN
Country
Dudley
Phone
Tel: 0121 557 5411 Fax: 0121 557 5345

View All Listings by this Company

Print This Approval


#2010909

BS EN 14055: 2018 concealed WC cistern incorporating a side entry compact type float operated inlet valve providing a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) with a pneumatic or cable operated drop valve capable of full flush volumes of up to 6 litres and reduced flush of up to 4 litres. The cistern is operated by manual push button. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2034 Cistern - Flushing
Section Subtitle:
Incorporating Type AB air gap, providing fluid category 5 backflow protection. Suitable for use in a WC suite.
WRAS Approval Number:
2010909
Expiry date:
31/10/2025
Size:
½” BSP Inlet connection.
Marking:
Top of cistern lid marked ‘DUDLEY OSMO T1’. Top of outlet drop valve marked ‘TD’, Inlet valve discharge cap marked ‘HYDROFLO’. Front nut of inlet valve marked ‘DUDLEY BS 1212/4’.
Installation Requirements:
R001 R280 R574
Model:
OSMO T1 Concealed Cistern (Category 5).
Manufacturer:
Thomas Dudley Ltd
Company Name
Thomas Dudley Ltd
Address
Dauntless Works PO Box 28 New Birmingham Road
Postcode
DY1 4SN
Country
Dudley
Phone
Tel: 0121 557 5411 Fax: 0121 557 5345

View All Listings by this Company

Print This Approval


#2012904

BS EN 14055 (2018) concealed WC cistern incorporating a side entry compact type float operated inlet valve discharging via a type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5) and a dual or single flush pneumatic or dual flush cable operated drop valve capable of full flush volumes of up to 6 litres with a reduced flush of up to 4 litres. The cistern is operated by manual push button/push plate. One of the side entry inlet valves is mounted internally and is supplied via a stainless steel braided EPDM lined flexible hose assembly which incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2034 Cistern - Flushing
Section Subtitle:
Incorporating Type AB air gap, providing fluid category 5 backflow protection. Suitable for use in a WC suite.
WRAS Approval Number:
2012904
Expiry date:
31/12/2025
Size:
½” BSP Male or 15mm Push-fit Inlet connection
Marking:
Top of outlet drop valve marked ‘TD’, Inlet valve discharge cap marked ‘HYDROFLO’. Front nut of inlet valve marked ‘DUDLEY BS 1212/4’.
Installation Requirements:
R001 R280 R574
Model:
OBC Concealed Cistern (Category 5)
Manufacturer:
Thomas Dudley Ltd
Company Name
Thomas Dudley Ltd
Address
Dauntless Works PO Box 28 New Birmingham Road
Postcode
DY1 4SN
Country
Dudley
Phone
Tel: 0121 557 5411 Fax: 0121 557 5345

View All Listings by this Company

Print This Approval


#2101907

BS EN 14055: 2018 concealed WC flushing cistern incorporating a side entry compact type float operated inlet valve providing a Type AB air gap and lever operated syphon capable of full flush volumes of up to 6 litres and reduced flush of up to 4 litres. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2034 Cistern - Flushing
Section Subtitle:
Incorporating Type AB air gap, providing fluid category 5 backflow protection. Suitable for use in a WC suite.
WRAS Approval Number:
2101907
Expiry date:
31/01/2026
Size:
½” BSP Inlet connection.
Marking:
Top syphon marked ‘DUDLEY TURBO EDGE’. Front cover marked ‘Dudley’, Inlet valve discharge cap marked ‘HYDROFLO’. Front nut of inlet valve marked ‘DUDLEY BS 1212/4’.
Installation Requirements:
R001 R280 R574
Model:
OSMO F1 Concealed Cistern (Category 5).
Manufacturer:
Thomas Dudley Ltd
Company Name
Thomas Dudley Ltd
Address
Dauntless Works PO Box 28 New Birmingham Road
Postcode
DY1 4SN
Country
Dudley
Phone
Tel: 0121 557 5411 Fax: 0121 557 5345

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.