Unvented Heating Apparatus

Section Code 1890 :

Back To Directory Sections

#1911060

BTMB Range of stainless steel indirect unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 95°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit 6.0 bar. Primary circuit 10.0 bar Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911060
Expiry date:
30/11/2024
Size:
22mm compression (manifold). 22mm Stub connection (hot outlet). 22mm Stub connection (secondary return). 22mm Stub connection (coil 1). 32mm Stub connection (coil 2).
Marking:
SAHP, Model number and technical information including capacity and pressure on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
BTMB 130 BTMB 200 & BTMB 300
Factor:
SAHP LIMITED
Company Name
SAHP LIMITED
Address
UNIT 2 GALIFORD ROAD MALDON ESSE
Postcode
CM9 4XD

View All Listings by this Company

Print This Approval


#2006003

Range of indirectly heated stainless-steel storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar@90˚C. A safety kit (manifold) consisting of a check valve, strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.5 bar is provided. A tundish, expansion vessel and an approved filling loop is also supplied Maximum working pressure secondary circuit 5.5 bar. Maximum operating pressure primary circuit 2.5 bar. Maximum operating temperature 70˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2006003
Expiry date:
30/06/2025
Marking:
Mitsubishi and Ecodan on front of unit. Mitsubishi, model and technical info including pressures and capacity on adhesive label on top of unit.
Installation Requirements:
R001 R140 R530 R360
Model:
EHPT20X-MHCW. EHST20C-MHCW. EHST20D-MHCW.
Manufacturer:
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Company Name
Mitsubishi Electric Air Conditioning Systems Europe Ltd
Address
Nettlehill Road, Houston Industrial Estate, Livingston
Postcode
EH54 5EQ
Country
United Kingdom
Phone
01405 44 55 00

View All Listings by this Company

Print This Approval


#2007040

Fabdec ‘Excelsior’ ranges of direct, indirect, solar direct and solar indirect stainless steel insulated unvented hot water storage cylinders with internal expansion. The DHW circuit consists of a temperature and pressure relief valve set at 7.0 bar 95°C, an inlet manifold consisting of an in-line pressure reducing valve adjustable between 2.7 & 3.3 bar (but factory set @ 3.0 bar), an approved check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2), a pre-set expansion relief valve set at 6.0 bar and a strainer. The product is supplied with a tundish. Maximum supply pressure to pressure reducing valve is 10.0 bar. Maximum working pressure Primary circuit 6.0 bar. Maximum working pressure Secondary circuit 5.5 bar. Maximum operating temperature 85˚C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2007040
Expiry date:
31/07/2025
Note:
All solar models must be installed in accordance with this proviso: WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed as part of a system using solar energy or ground- or air- source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulations place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20°c and 45°C.
Size:
See model
Marking:
Adhesive label on side of cylinder with manufacturers name (Fabdec), model, address and technical information including temperature, capacity and pressure.
Installation Requirements:
R001 R140 R360
Model:
Internal expansion ranges. Excelsior Direct, Indirect, Solar Direct & Solar Indirect Cylinders range: 80ltr, 130ltr, 150ltr, 175ltr, 215ltr, 255ltr, 300ltr, 400ltr, 500ltr.
Manufacturer:
Fabdec Ltd
Company Name
Fabdec Ltd
Address
Grange Road Ellesmere Shropshire
Postcode
SY12 9DG

View All Listings by this Company

Print This Approval


#1911070

Range of Stuart Aquastor Eco stainless steel indirect and direct unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 95°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit 6.0 bar. Primary circuit 10.0 bar Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911070
Expiry date:
30/11/2024
Size:
22mm compression (manifold). 22mm Stub connection (hot outlet). 22mm Stub connection (secondary return). 22mm Stub connection (coil 1). 32mm Stub connection (coil 2).
Marking:
STUART TURNER, part number and technical information including capacity and pressure on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
Indirect- Stuart Aquastor Eco: 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L SAE 130 SAE 150 SAE 215 SAE 255 SAS 305 SAS400 SAS 500
Factor:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley on Thames Oxon
Postcode
RG9 2AD
Country
United Kingdom
Phone
01491 572655
General Email
pumps@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


#2011335

Range of vertical cased and insulated direct and indirect unvented stainless steel hot water storage cylinders. The storage cylinders incorporate an internal air bubble to accommodate the expansion of hot water. The DHW circuit has a factory fitted temperature and pressure relief valve set at 10.0@90˚C. The inlet control group includes a pressure reducing valve set at 3.0 bar, single check valve cartridge (verified by test and suitable for backflow protection against Fluid Category 2) and a expansion valve set at 8.0 bar. The products are supplied with a tundish and a motorised valve to be installed on the primary indirect circuit. Maximum supply pressure to the pressure reducing valve is 12.0 bar. Maximum working pressure of primary circuit is 6.0 bar. Maximum secondary circuit is 9.5 bar. Maximum operating temperature 85°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2011335
Expiry date:
30/11/2025
Size:
22mm compression
Marking:
Gledhill and product & technical information on adhesive label on body
Installation Requirements:
R001 R140 R360
Model:
Directs range PLTDR120 Platinum Int Exp Dir 120 PLTDR150 Platinum Int Exp Dir 150 PLTDR180 Platinum Int Exp Dir 180 PLTDR210 Platinum Int Exp Dir 210 PLTDR250 Platinum Int Exp Dir 250 PLTDR300 Platinum Int Exp Dir 300 Indirect range PLTIN120 Platinum Int Exp Ind 120 PLTIN150 Platinum Int Exp Ind 150 PLTIN180 Platinum Int Exp Ind 180 PLTIN210 Platinum Int Exp Ind 210 PLTIN250 Platinum Int Exp Ind 250 PLTIN300 Platinum Int Exp Ind 300 Pre-Plumbed Range PLTIN120PP Platinum Int Exp Ind 120 PP PLTIN150PP Platinum Int Exp Ind 150 PP PLTIN180PP Platinum Int Exp Ind 180 PP PLTIN210PP Platinum Int Exp Ind 210 PP PLTIN250PP Platinum Int Exp Ind 250 PP PLTIN300PP Platinum Int Exp Ind 300 PP System Plus Range PLTIN120PPSP Platinum Int Exp Ind 120 PPSP PLTIN150PPSP Platinum Int Exp Ind 150 PPSP PLTIN180PPSP Platinum Int Exp Ind 180 PPSP PLTIN210PPSP Platinum Int Exp Ind 210 PPSP PLTIN250PPSP Platinum Int Exp Ind 250 PPSP PLTIN300PPSP Platinum Int Exp Ind 300 PPSP System Ready Range PLTIN120PPSR Platinum Int Exp Ind 120 PPSR PLTIN150PPSR Platinum Int Exp Ind 150 PPSR PLTIN180PPSR Platinum Int Exp Ind 180 PPSR PLTIN210PPSR Platinum Int Exp Ind 210 PPSR PLTIN250PPSR Platinum Int Exp Ind 250 PPSR PLTIN300PPSR Platinum Int Exp Ind 300 PPSR
Manufacturer:
Gledhill Building Products Ltd
Company Name
Gledhill Building Products Ltd
Address
Sycamore Estate Blackpool
Postcode
FY4 3RL
Phone
(01253) 474439

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 4 of 11

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.