Unvented Heating Apparatus

Section Code 1890 :

Back To Directory Sections

#1909107

ZIP AQUAFLO II range of stainless steel direct and indirect, direct (solar) and indirect (solar) hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish and expansion vessel is also supplied. Maximum working pressure and temperature secondary circuit 5.5 bar @65°C Maximum operating pressure and temperature primary circuit 6.0 bar @80°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1909107
Expiry date:
30/09/2024
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Expansion vessels should be installed in the vertical orientation, and located so as to minimise the length of any connecting pipework.
Size:
90 litre, 120 litre, 150 litre, 180 litre, 210 litre, 250 litre, 300 litre,
Marking:
ZIP AQUAFLO II ON CYLINDER BODY ZIP AQUAFLO II, MODEL, PRESSURE, CAPACITY & TECHNICAL INFORMATION ON ADHESIVE LABEL ON BODY
Installation Requirements:
R001 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
AF3090-ZIP AQUFLO II 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF3120 -ZIP AQUAFLO II 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER AF3150 -ZIP AQUAFLO II 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF3180 -ZIP AQUAFLO II 180 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF3210 -ZIP AQUAFLO II 210 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF3250 -ZIP AQUAFLO II 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF3300 -ZIP AQUAFLO II 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4090 – ZIP AQUAFLO II 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4120 – ZIP AQUAFLO II 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4150 - ZIP AQUAFLO II 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4180 - ZIP AQUAFLO II 180 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4210 - ZIP AQUAFLO II 210 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4250 - ZIP AQUAFLO II 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF4300 - ZIP AQUAFLO II 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. AF6150 - ZIP AQUAFLO II 150 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. AF6180 - ZIP AQUAFLO II 180 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER AF6210 - ZIP AQUAFLO II 210 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. AF6250 - ZIP AQUAFLO II 250 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. AF6300 - ZIP AQUAFLO II 300 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. AF5150 - ZIP AQUAFLO II 150 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. AF5180 - ZIP AQUAFLO II 180 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. AF5210 - ZIP AQUAFLO II 210 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. AF5250 - ZIP AQUAFLO II 250 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. AF5300 - ZIP AQUAFLO II 300 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER.
Factor:
Zip Heaters (UK) Ltd.
Company Name
Zip Heaters (UK) Ltd.
Address
14/15 Bertie Ward Way Rash's Green Dereham
Postcode
NR19 1TE
Country
Norfolk
Phone
01632 853 181
General Email
sales@zipheaters.co.uk

View All Listings by this Company

Print This Approval


#1909108

PROSTEL range of stainless steel direct and indirect, direct (solar) and indirect (solar) hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve set at 7.0 bar and 90˚C. A safety kit (manifold) consisting of a single check valve cartridge (verified by test, suitable for backflow protection against Fluid Category 2), strainer, an expansion relief valve set at 6.0 bar and pressure reducing valve set at 3.0 bar. A tundish and expansion vessel is also supplied. Maximum working pressure and temperature secondary circuit 5.5 bar @65°C Maximum operating pressure and temperature primary circuit 6.0 bar @80°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1909108
Expiry date:
30/09/2024
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999. Expansion vessels should be installed in the vertical orientation, and located so as to minimise the length of any connecting pipework.
Size:
90 litre, 120 litre, 150 litre, 180 litre, 210 litre, 250 litre, 300 litre
Marking:
PROSTEL UNVENTED HEATER ON CYLINDER RM PROSTEL, MODEL, PRESSURE, CAPACITY & TECHNICAL INFORMATION ON ADHESIVE LABEL ON BODY
Installation Requirements:
R001 R360
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
TRPMVD-0090LFC -RM PROSTEL 90 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVD-0120LFB -RM PROSTEL 120 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVD-0150LFB -RM PROSTEL 150 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVD-0180LFB -RM PROSTEL 180 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVD-0210LFC -RM PROSTEL 210 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVD-0250LFC -RM PROSTEL 250 DIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVD-0300LFC -RM PROSTEL 300 DIRECT UNVENTED HOT WATER STORAGE CYLINDER TRPMVI-0090LFC -RM PROSTEL 90 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVI-0120LFB -RM PROSTEL 120 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVI-0150LFB -RM PROSTEL 150 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVI-0180LFB -RM PROSTEL 180 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVI-0210LFC -RM PROSTEL 210 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVI-0250LFC -RM PROSTEL 250 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVI-0300LFC -RM PROSTEL 300 INDIRECT UNVENTED HOT WATER STORAGE CYLINDER. TRPMVE-0150LFB -RM PROSTEL 150 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRPMVE-0180LFB -RM PROSTEL 180 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER TRPMVE-0210LFC -RM PROSTEL 210 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRPMVE-0250LFC -RM PROSTEL 250 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER. TRPMVE-0300LFC -RM PROSTEL 300 DIRECT SOLAR UNVENTED HOT WATER STORAGE CYLINDER TRPMVS-0150LFB -RM PROSTEL 150 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRPMVS-0180LFB -RM PROSTEL 180 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRPMVS-0210LFC -RM PROSTEL 210 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRPMVS-0250LFC -RM PROSTEL 250 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER. TRPMVS-0300LFC -RM PROSTEL 300 INDIRECT SOLAR TWIN UNVENTED HOT WATER STORAGE CYLINDER.
Factor:
RM Cylinders
Company Name
RM Cylinders
Address
4 Valencia Park, Gilcar Way, Wakefield Europort
Postcode
WF10 5QS
Country
West Yorkshire

View All Listings by this Company

Print This Approval


#1911012

Range of “Excelsior” stainless steel indirect and direct unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 95°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit 6.0 bar. Primary circuit 10.0 bar Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911012
Expiry date:
30/11/2024
Size:
22mm compression (manifold). 22mm Stub connection (hot outlet). 22mm Stub connection (secondary return). 22mm Stub connection (coil 1). 32mm Stub connection (coil 2). The above sizes on the approval to be modified to the below: 22mm or 28mm compression connection (manifold) secondary inlet, 22mm or 28mm stub connection secondary outlet 22mm stub or ½”F BSP secondary return 22mm stub connections coil1 inlet and outlet 28mm or 32mm stub connections cold inlet and outlet
Marking:
Fabdec, part number and technical information including capacity and pressure on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
Product Range: External expansion ranges: Excelsior Direct:80L, 100L, 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Excelsior indirect: 80L, 100L, 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Excelsior Solar Direct: 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Excelsior Solar Indirect: 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L Excelsior Heat Pump (single coil): 150L, 175L, 215L, 255L, 305L,400L, 500L Excelsior Heat Pump (twin coil): 150L, 175L, 215L, 255L, 305L, 400L, 500L Excelsior Direct slim line: 100L, 130L, 150L, 175L, 210L Excelsior indirect slim line: 100L, 130L, 150L, 175L, 210L Excelsior Direct super slim line: 80L, 100L, 130L, 150L, 165L Excelsior indirect super slim line: 80L, 100L, 130L, 150L, 165L Excelsior Renewables’, slim line: 100L. 130L, 150L, 175L, 210L Excelsior Buffer: 80L, 100L, 130L, 150L, 175L, 215L, 255L, 305L, 400L, 500L
Factor:
Fabdec Ltd
Company Name
Fabdec Ltd
Address
Grange Road Ellesmere Shropshire
Postcode
SY12 9DG

View All Listings by this Company

Print This Approval


#1911034

Range of MAXXflo EVO free standing gas fired stainless steel unvented storage cylinders. The heaters are supplied with temperature and pressure relief valves (rated 10.0 bar @ 95°C), pressure reducing valve (rated 6.0 bar) & expansion relief valve (rated 8.0 bar). The manifold incorporates a stainless-steel strainer, flexible hose, expansion vessel and approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 7.5 bar. Cold water supply only.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911034
Expiry date:
30/11/2024
Size:
1½” BSP (M)
Marking:
Andrews Water Heaters & technical information on adhesive label.
Installation Requirements:
R001 R530 R140 R360
Model:
CWH 30/201 (30kW heat input with 200 litre tank) CWH 30/301 (30kW heat input with 300 litre tank) CWH 60/201 (60kW heat input with 200 litre tank) CWH 60/301 (60kW heat input with 300 litre tank) CWH 90/302 (90kW heat input with 300 litre tank) CWH 120/302 (120kW heat input with 300 litre tank)
Factor:
Andrews Water Heaters
Company Name
Andrews Water Heaters
Address
Baxi Commercial Division Wood Lane Erdington
Postcode
B24 9QP
Country
Birmingham
Phone
0845 070 1056
General Email
andrews@andrews-waterheaters.co.uk

View All Listings by this Company

Print This Approval


#1911059

Range of “Mixergy” stainless steel indirect and direct unvented hot water storage cylinders. The secondary circuit is factory fitted with a temperature and pressure relief valve (7.0 bar and 95°C). The product is fitted with a safety kit which comprises of a manifold, check valve cartridge, verified by test (suitable for backflow protection against Fluid Category 2) strainer, an expansion relief valve set at 6.0 bar and a pressure reducing valve set at 3.0 bar. A tundish and expansion vessel also comes supplied. Maximum working pressure: Secondary circuit 6.0 bar. Primary circuit 10.0 bar Maximum operating temperature 85°C

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
1911059
Expiry date:
30/11/2024
Size:
22mm compression (manifold). 22mm Stub connection (hot outlet). 22mm Stub connection (secondary return). 22mm Stub connection (coil 1). 32mm Stub connection (coil 2).
Marking:
MIXERGY, part number and technical information including capacity and pressure on adhesive label on body
Installation Requirements:
R001 R140 R360 R530
Proviso:
WRAS Approval - Solar heating system components. “Compliance with the relevant requirements of the Water Supply (Water Fittings) Regulations 1999 has been assessed for this product only as a component of a heating system. If it is to be installed a s part of a system using solar energy or ground - or air - source heat pumps for pre-heating water which is to be used as domestic hot water, the Water Fittings Regulation place a legal duty on the installer and user to ensure that the installation and operation of the complete system prevents contamination of domestic hot water by Legionella bacteria, which can grow in water stored at temperatures between 20˚C and 45˚C. Where disinfection by heating is relied on to meet this obligation, information on minimum conditions for thermal disinfection of legionella bacteria can be found on the WRAS website - www.wras.co.uk
Model:
MIXERGY DIRECT CYLINDER 90L, 130L, 150L, 175L & 215L MIXERGY INDIRECT CYLINDER 130L, 150L, 175L, 215L & 305L
Factor:
Mixergy Ltd.
Company Name
Mixergy Ltd.
Address
2 Canal View Wharf Farm Eynsham
Postcode
OX29 4DB
Country
Oxfordshire

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 3 of 11

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.