Section Code 1478 : Combination boilers - accessories and components.
Back To Directory SectionsRange of self-acting controllers with brass bodies, EPDM O rings and gaskets. Maximum operating pressure 16.0 bar. Maximum operating temperature of the secondary circuit 65˚C, and the primary circuit is 99˚C.
Preheat accessory assembly for connection to the domestic hot water circuit of a combination boiler. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Permanent filling device for primary heating and chilled water closed circuits in domestic and non-domestic premises. The mains and closed circuit system pressures are continuously checked by two pressure sensors and their differential monitored by microprocessors. In the event of a fall in system pressure, and only if the mains pressure is adequate, two solenoid valves operate to allow water into the system via the transfer chamber. At all other times the normally open solenoid valve drains the transfer chamber to waste, via tundish (meeting the requirements of an air gap to drain), and allowing air to be admitted via an automatic air vent to create an atmospheric disconnection across the transfer chamber. Maximum working pressure 5.0 Bar. Cold water use only.
Spherical valve with brass body and ball, PTFE seat, EPDM and NBR ‘O’-rings. The valve is intended for installation on the cold water inlet of a combination boiler and incorporates a branch to supply the primary circuit. Maximum working pressure 10.0 Bar. Cold water use only
‘Hydraulic Block 2’ range of integrated water circuits for use with combination boilers comprising of a plastic body, stainless steel thermistors and a plate heat exchanger. The primary circuit incorporates a pump assembly. Maximum working pressures: Primary Circuit 2.5 bar. Secondary Circuit 10.0 bar. Maximum operating temperatures: Primary circuit 85˚C. Secondary circuit 65°C. Cold supply only.
Hydroblock unit consisting of a stainless steel heat exchanger, a pressure relief valve pre-set at 3.0 bar, diverter valve and return valve. Maximum working pressure 2.5 bar. Maximum operating temperature 90°C
Hydraulic block assembly comprising a flow sensor, primary pump assembly, pressure relief valve preset at 3.0 bar and plate heat exchanger. Maximum working pressures: secondary = 10.0 bar and primary = 2.5 bar. Maximum operating temperature 80°C.
Hydraulic block assembly comprising of a flow regulator, central heating pump assembly and a stainless-steel plate heat exchanger. Maximum working pressures: DHW circuit: 10.0 Bar Central heating circuit: 2.5 Bar Maximum operating temperature: DHW Circuit: 65.0°C Central heating circuit: 90.0°C
Hydraulic block incorporating heat exchangers with pressed stainless-steel plate bodies and copper brazing. Product also incorporates primary and secondary water way with PPS plastic fittings and adaptors and a flow adjustment valve. Maximum operating temperature: 65ºC Maximum working pressure: Central Heating Circuit: 2.5 bar Direct Hot Water Circuit: 10 bar