Heat Exchangers

Section Code 1350 :

Back To Directory Sections

#2010035

Range of stainless steel, copper brazed plate type heat exchangers. Maximum working pressure 30.0 bar. Maximum operating temperature 100°C.

Section:
1350 Heat Exchangers
WRAS Approval Number:
2010035
Expiry date:
31/10/2025
Size:
1 1\2” BSP(M) or 2” BSP (M).
Marking:
UK Exchangers Ltd, max Pressure, max Temperature, WRAS, model number and other technical info on adhesive label on body.
Installation Requirements:
R001
Model:
UKE-BR200L UKE-BR200M UKE-BR205 Available in 20/30/40/50/60/80/100/120 Plates.
Factor:
UK Exchangers Ltd.
Company Name
UK Exchangers Ltd.
Address
Unit 55 Stilebrook Road Olney
Postcode
MK46 5EA
Country
Buckinghamshire

View All Listings by this Company

Print This Approval


#2010374

Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The inlet and outlet of all circuits incorporates lever operated spherical valves with brass bodies. 274.xx9x.696 models all have the following additional items over the 274.xx1x.696 models: Heatmeter on the primary circuit, a flushing bypass between the primary and space heating circuits and a safety relief valve (set at 10.0 bar) on the cold supply to the heat exchanger of the domestic hot water circuit. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 9.5 bar and 60˚C. Secondary (space heating): 2.5 bar and 85˚C.

Section:
1350 Heat Exchangers
WRAS Approval Number:
2010374
Expiry date:
31/10/2025
Note:
Not supplied with a temporary filling loop. A filling loop must be installed with the appropriate backflow prevention device in accordance with Schedule 2 paragraph 24to the Water Supply (Water Fittings) Regulations 1999.
Size:
¾” BSP (F)
Marking:
Taconova Group AG and other technical information on control panel. Pressure, temperature, WRAS, type and other technical information on inside cover.
Installation Requirements:
R001 R140 R360
Model:
274.2411.696 HL3000E 10/26. 274.2491.696 HL3000E 10/26. 274.2611.696 HL3000E 10/40. 274.2691.696 HL3000E 10/40. 274.4411.696 HL3000E 16/26. 274.4491.696 HL3000E 16/26. 274.4611.696 HL3000E 16/40. 274.4691.696 HL3000E 16/40. 274.6411.696 HL3000E 26/26. 274.6491.696 HL3000E 26/26. 274.6611.696 HL3000E 26/40. 274.6691.696 HL3000E 26/40. 274.6711.696 HL3000E 26/50. 274.6791.696 HL3000E 26/50. Where final part of code denotes the number of plates on the heat exchanger, e.g. 10/26, 10 = number of plates on the space heating circuit, 26 = the number of plates on the domestic hot water circuit.
Factor:
HeatliNK
Company Name
HeatliNK
Postcode
S6 1JF

View All Listings by this Company
Manufacturer:
Taconova Production s.r.o.
Company Name
Taconova Production s.r.o.
Address
Nova UL. C 627, CZ-38232 Velesin, Czech Republic

View All Listings by this Company

Print This Approval


#2010310

Uponor Combi Port range of indirect heat interface units providing heating and instantaneous hot water. The heating system incorporates an expansion vessel and pressure relief valve (set at 3.0 bar).Some units have optional ball valve sets. Primary side heating 85°C and 2.5 bar. Secondary side, space heating 60°C and 2.5 bar. Secondary side DHW 60°C and 4.0 bar.

Section:
1350 Heat Exchangers
WRAS Approval Number:
2010310
Expiry date:
31/10/2025
Size:
See model
Marking:
Uponor, model no, serial no & date of manufacture (DD.MM.YYYY) on inside cover.
Installation Requirements:
R001 R140 R360
Model:
Uponor Combi Port base XU: 1095642 15l/min 1095643 21l/min 1095644 29l/min Optional ball valve set 101802 for models 1095644 & 1095642 Uponor Combi Port PRO XU: 1095636 15l.min 1095637 21l/min Optional Ball valve set 1037536
Factor:
Uponor GmbH
Company Name
Uponor GmbH
Address
Industriestraße 56, 97437 Hassfurt
Country
Germany
Phone
0034916853600

View All Listings by this Company

Print This Approval


#2011003

Range of copper brazed, stainless steel heat exchangers in various sizes (4-300 plates, see model). Models size X8T-SC-S Maximum working pressure primary circuit: 32.0 bar Maximum working pressure secondary circuit: 26.0 bar Maximum operating temperature: 99°C Models size 10T-SC-M Maximum working pressure primary circuit: 41.0 bar Maximum working pressure secondary circuit: 36.0 bar Maximum operating temperature: 99°C Models size 15T-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45 bar Maximum operating temperature: 99°C Models size 16DW-SC-S Maximum working pressure primary circuit: 16.0 bar Maximum working pressure secondary circuit: 16.0 bar Maximum operating temperature: 99°C Models size 16DW-SC-M Maximum working pressure primary circuit: 45.0 bar Maximum working pressure secondary circuit: 45.0 bar Maximum operating temperature: 99°C Models size 220-SC-S Maximum working pressure primary circuit: 25.0 bar Maximum working pressure secondary circuit: 25.0 bars Maximum operating temperature: 99°C Models size 320HT-SC-S Maximum working pressure primary circuit: 33.0 bar Maximum working pressure secondary circuit: 29.0 bar Maximum operating temperature: 99°C Models size 320LT-SC-S Maximum working pressure primary circuit: 33.0 bars Maximum working pressure secondary circuit: 29.0 bars Maximum operating temperature: 99°C

Section:
1350 Heat Exchangers
WRAS Approval Number:
2011003
Expiry date:
30/11/2025
Size:
See model
Marking:
SWEP, year of manufacture and technical information on adhesive label on body
Installation Requirements:
R001
Model:
Models X8T-SC-S Connection types: ½”, ¾” " External threaded male Number of plates minimum: 4 Number of plates maximum: 60 Models 10T-SC-M Connection types: 3/8” to 1 1/4 " External threaded male Number of plates minimum: 4 Number of plates maximum: 140 Models 15T-SC-M Connection types: ½” to 1” External threaded male Number of plates minimum: 4 Number of plates maximum: 60 Models 16DW-SC-S Connection types: ½” to 1 1/4” External threaded male Number of plates minimum: 4 Number of plates maximum: 140 Models 16DW-SC-M Connection types: ½” to 1 1/4” External threaded male Number of plates minimum: 4 Number of plates maximum: 140 Models 220-SC-S Connection types: 1” to 2 1/2” External threaded male Number of plates minimum: 4 Number of plates maximum: 300 Models 320HT-SC-S Connection types: 1 ½” to 2 1/2” External threaded male Number of plates minimum: 4 Number of plates maximum: 300 Models 320LT-SC-S Connection types: 1 ½” to 3” External threaded male Number of plates minimum: 4 Number of plates maximum: 260
Factor:
SWEP International AB
Company Name
SWEP International AB
Address
Box 105, 26122 Landskrona, Sweden

View All Listings by this Company
Manufacturer:
SWEP Slovakia s.r.o | SWEP Malaysia sdn Bhd
Company Name
SWEP Slovakia s.r.o | SWEP Malaysia sdn Bhd
Address

View All Listings by this Company

Print This Approval


#2012058

Range of waste water heat recovery systems incorporating a twin wall copper coil (iZi models) or stainless steel (PiPe models). Maximum working pressure 10.0 bar. Cold water use only.

Section:
1350 Heat Exchangers
WRAS Approval Number:
2012058
Expiry date:
31/12/2025
Size:
½” BSP (M) (iZi 30 & 40) or ¾” BSP (F) (PiPe 65 & 70)
Marking:
Zypho, Model, WRAS and technical info on adhesive label located on plastic casing.
Installation Requirements:
R001
Model:
ZYPHO iZi 30, ZYPHO iZi 40, ZYPHO PiPe 65, ZYPHO PiPe 70
Manufacturer:
Zypho, SA
Company Name
Zypho, SA
Country
Portugal
Phone
+351 210 991 351

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 4 of 11

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.