Concealed wall insulation unit with a brass body and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.
Range of isolation valves with a brass body (various surface finishes - see model) and either a quarter turn ceramic disc (PEX-230-C/P and PEX-231-C/P models) or a non-rising spindle (all other models) with various operating members (see model) and NBR ‘O’-rings. The inlet of the PEX-230-C/P and PEX-231-C/P models incorporates a stainless-steel strainer. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.
Wall bracket with a brass body (chrome plated) and EPMD ‘O’-rings. Maximum operating temperature 85°C.
Centrifugal pump with a stainless steel casing and shaft, silicon carbide and EPDM shaft seals, NBR ‘O’-rings and washers. Maximum working pressure 8.0 bar. Maximum operating temperature 45°C.
Range of inline circulating pumps with bronze bodies, plastic impeller and EPDM rubber seals. Maximum working pressure 10.0 bar. Maximum operating temperature 100°C.
Range of booster pumps with stainless steel bodies and impellers, EPDM ‘O’-rings and a ceramic/graphite/EPDM shaft seal. Maximum working pressure 6.0 bar. Maximum operating temperature 40°C.
Range of booster pumps with stainless steel bodies and impellers, EPDM ‘O’-rings and a ceramic/graphite/EPDM shaft seal. Maximum working pressure 7.0 bar. Cold water use only. From November 2021 maximum operating temperature 60°C
Range of cast iron (blue epoxy coated) (G versions only) or stainless steel (all other versions - F, N, R, T) vertical multistage pumps with stainless steel impellers, shaft and outer sleeve and EPDM 'O'-rings and seals. The pumps incorporate a ceramic/carbon graphite/EPDM and stainless steel mechanical shaft seal (QBEGG). Maximum working pressures: 1-22SV models: 1SV27-1SV37 (F VERSION) - PN16 (25mm). 3SV23-3SV33 (F VERSION) - PN16 (25mm). 5SV23-5SV33 (F VERSION) - PN16 (32mm). 10SV27-10SV21 (F VERSION) - PN16 (40mm). 15SV11-15SV17 (F VERSION) - PN16 (50mm). 22SV12-22SV17 (F VERSION) - PN16 (50mm). 1SV02-1SV25 (F VERSION) - PN25 (25mm). 3SV02-3SV21 (F VERSION) - PN25 (25mm). 5SV02-5SV16 (F VERSION) - PN25 (32mm). 10SV01-10SV13 (F VERSION) - PN25 (40mm). 15SV01-15SV10 (F VERSION) - PN25 (50mm). 22SV01-22SV10 (F VERSION) - PN25 (50mm). N VERSIONS ALL MODELS - PN25 (25-50mm). R VERSION ALL MODELS - PN25 (25-50mm). T VERSION ALL MODELS - PN16 (25-50mm). 33-125SV models: 33SV1-33SV5, 33SV6/2AG150T/D & 33SV6/2AN150T/D (G or N VERSION) - PN16 (65mm). 46SV1-46SV5 (G or N VERSION) - PN16 (80mm). 66SV1-66SV5 (G or N VERSION) - PN16 (100mm). 92SV1-92SV4 (G or N VERSION) - PN16 (100mm). 125SV1-125SV6 (G VERSION) - PN16 (125mm). 33SV7-33SV10, 33SV6/1AG150T/D, 33SV6/1AN150T/D, 33SV6G150T/D & 33SV6N150T/D (G VERSION) - PN25, (N VERSION) - PN16 (65mm). 46SV6-46SV9 (G VERSION) - PN25, (N VERSION) - PN16 (80mm). 66SV6-66SV8 (G VERSION) - PN25, (N VERSION) - PN16 (100mm). 92SV5-92SV7 (G VERSION) - PN25, (N VERSION) - PN16 (100mm). 125SV7-125SV8 (G VERSION) - PN25 (125mm). 33SV10-33SV13 (G VERSION) - PN40 (65mm). 46SV10-46SV13 (G VERSION) - PN40 (80mm). Cold water use only. VERSION) - PN25 (100mm). 92SV5-92SV7 (G or N VERSION) - PN25 (100mm). 125SV7-125SV8 (G or N VERSION) - PN25 (125mm). 33SV10-33SV13 (G VERSION) - PN40 (65mm). 46SV10-46SV13 (G VERSION) - PN40 (80mm). Cold water use only.
Range of shower handsets with chrome plated bodies and built in flow restrictors. Maximum operating temperature 60°C.
Range of rim/deck mounted shower handsets with brass bodies (various finishes). The inlet (except for the D5A A02 60A/W model) incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The inlet of the D5A A02 60A/W model incorporates a plastic flow restrictor. The products are supplied with a shower hose and a stainless steel braided EDPM lined flexible hose assembly (for connection prior to the shower hose). Maximum working temperature 60°C.
Range of shower rose outlets (plastic body with various finishes). The inlet incorporates a stainless-steel strainer. Maximum operating temperature 60°C. Open outlet use only.
Range of shower outlets with brass bodies (various finishes) incorporating NBR ‘O’-rings. Maximum operating temperature 60°C.
Range of shower heads and a shower handset. The shower heads have a stainless steel body and ball joint, silicon ‘O’-rings and nozzles, and the inlet incorporates a combined NBR washer and stainless steel filter. The shower handset has a stainless steel body, NBR ‘O’-rings and silicon nozzles. All products incorporate a plastic flow regulator on the inlet. Maximum operating temperature 60°C.
Range of wall mounted or ceiling mounted shower arms with brass bodies (various finishes) Maximum operating temperature 90°C.
Handshower with a chrome plated plastic body. The inlet incorporates a single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C.
Range of wall or ceiling mounted shower arms and a wall mounted shower outlet + holder. The products incorporate a stainless steel bodies (various finishes). Maximum operating temperature 60°C.
Shower arm incorporating a stainless steel body. Maximum operating temperature 85°C.
Dolphin Blue Flexi hose range of wall outlets and brackets incorporating stainless steel bodies (various finishes) and EPDM ‘O’-rings. Maximum operating temperature 85°C
Dolphin Blue range of handheld shower outlets with a stainless bodies (various finishes) and EPDM ‘O’-rings. The inlet incorporates a single check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 85°C
Shower handsets (chromium plated ABS) with stainless steel strainers and a built-in approved single check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum operating temperature 60°C
Page 97 of 561
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.