Section Code 5030 : Factory applied pipe & fittings coatings.
Back To Directory Sections'RAL 5005 Epoxy Coating'. Factory applied, blue coloured Epoxy Coating. Apply as per manufacturer's TDS '31.05.2024'. Cure for 10 minutes@200°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'LM-coat'. Factory applied, blue coloured, two-part Polyurea coating. Mix Part A (KOBECASE PS-6031) with Part B (COBENATE I-362) in a 100:100 volume ratio and apply as per manufacturer's TDS 'Rev. no: 02', dated '16.02.2022'. Cure for 4 hours@10°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘ResiGard APUA (NT) Coating'. Factory applied, grey coloured (once mixed), two-component coating. Mix and apply as per Technical Data Sheet ‘PDS/RG37/Ver15/01/25’. Cure for 1 minute@25°C. For use with water up to 85°C.
'Greentech 5000'. Factory applied, blue coloured Epoxy powder coating. Apply as per manufacturer's 'GRHK/QES GL 2025' and cure for 10 minutes@200°C. For use with water up to 50°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'PolyQuick® P-500 PW'. Factory applied, two component, grey coloured polyurea coating. Mix components A & B in a weight ratio of 1:1 and apply as per manufacturer's TDS 'v. 05-2025'. Cure for 48 hours@23°C. Between September 2022 and August 2024, the coating is for use with water up to 23°C. From September 2024, the coating is for use with water up to 60°C. This material is only approved for the mixing, curing & soaking conditions that appear on the approval. If the mix/cure/soak conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Page 96 of 103
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.