Directory Search Results

Print List

#2105309

Copper heat transformer. Maximum working pressure 11.0 bar. Maximum operating temperature 95°C.

Section:
1350 Heat Exchangers
Size:
76mm copper tube
Marking:
Company name and address, model, operating parameters, size & date of manufacture (MM/YYYY) on body.
Installation Requirements:
R001
Expiry date:
31/05/2026
Model:
Heat Transformer 60
Product Images

Approval Holder:
Copper Industries Ltd
Company Name
Copper Industries Ltd
Address
Toome Business Park 21 Hillhead Road Toome Co Antrim
Postcode
BT41 3SF
Country
United Kingdom
Phone
02879 659736
General Email
mail@copperindustries.co.uk

View All Listings by this Company
Manufacturer:
Copper Industries Ltd
Company Name
Copper Industries Ltd
Address
Toome Business Park 21 Hillhead Road Toome Co Antrim
Postcode
BT41 3SF
Country
United Kingdom
Phone
02879 659736
General Email
mail@copperindustries.co.uk

View All Listings by this Company

Print This Approval


#2105044

Range of domestic hot water units incorporating instantaneous or semi-instantaneous plate heat exchanger assemblies. The product incorporates a motorised control valve, managed primary and secondary pumps (see model), and a drain valve on both circuits. Maximum working pressures: 10.0 bar primary, 9.5 bar secondary. Maximum operating temperatures: 110°C primary, 85°C secondary.

Section:
1350 Heat Exchangers
Size:
1 ¼” BSP (F) on both primary and secondary circuits.
Marking:
Cetetherm SAS, AQUAFIRST, Max working pressure/temperature for primary and secondary circuits, serial number, article number and year of manufacture (YYYY) on adhesive label on heat exchanger frame.
Installation Requirements:
R001 R140 R360
Expiry date:
31/05/2026
Model:
AQUAFIRST 2000/4000/6100/8000 series: Flxxnnyy FI = Aquafirst range xx = 20: 2000 M3 Plates serie (differentiation on primary side). 40: 4000 M3 Plates serie (differentiation on primary side). 61: 6100 M6 Plates serie (differentiation on primary side and secondary pump). 80: 8000 M6 Plates serie (differentiation on primary side and secondary pump). nn = 07 up to 55 for the number of gasketed plates. yy = IS: Instantaneous (no pump on DHW) with single primary pump ID: Instantaneous (no pump on DHW) with twin head primary pump SS: Semi-instantaneous with one primary pump and one DHW pump DS: Semi-instantaneous with twin head primary pump and one DHW pump DD: Semi-instantaneous with twin head primary pump and two DHW pump Article Number: FI2007IS. FI2007ID. FI2007SS. FI2007DS. FI2007DD. FI2017IS. FI2017ID. FI2017SS. FI2017DS. FI2017DD. FI4027IS. FI4027ID. FI4027SS. FI4027IS. FI4027DD. FI4045IS. FI4045ID. FI4045SS. FI4045DS. FI4045DD. FI6113IS. FI6113ID. FI6113SS. FI6113DS. FI6113DD. FI6123IS. FI6123ID. FI6123SS. FI6123DS. FI6123DD. FI8031IS. FI8031ID. FI8031SS. FI8031DS. FI8031DD. FI8055IS FI8055ID FI8055SS FI8055DS FI8055DD.
Product Images

Approval Holder:
CETETHERM SAS
Company Name
CETETHERM SAS
Address
Route du stade ZI du moulin Pontcharra sur Turdine
Postcode
69490
Country
France
General Email
jeanmichel.montoni@cetetherm.com

View All Listings by this Company
Manufacturer:
CETETHERM SAS
Company Name
CETETHERM SAS
Address
Route du stade ZI du moulin Pontcharra sur Turdine
Postcode
69490
Country
France
General Email
jeanmichel.montoni@cetetherm.com

View All Listings by this Company

Print This Approval


#2107804

Ranges of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. Products are supplied with a rigid filling loop or keyless filling link. Maximum working pressure of the primary circuit is 2.5 bar & maximum supply pressure of the secondary circuit is 8.0 bar. Cold water supply only. Maximum operating temperature 95°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2107804
Note:
The rigid filling loop assembly incorporates a double check valve assembly (verified by test as suitable for backflow protection against fluid category 3). The keyless filling link incorporates a CAB backflow prevention device (verified by test as suitable for backflow protection against fluid category 3). The discharge from the relief outlet port of this device must be made via a type AA, AB or AD air gap, or in accordance with EN 1717.
Size:
Primary: 28mm compression. Secondary: 15mm compression.
Marking:
Baxi on front of boiler.
Installation Requirements:
R001 R140 R360
Expiry date:
31/07/2026
Model:
Baxi 224 Combi (product code 7656160). Baxi 228 Combi (7656161). Baxi 424 Combi (7656162). Baxi 428 Combi (7656163). Baxi 428 Combi LPG (7676760).

Approval Holder:
Baxi Heating UK Ltd.
Company Name
Baxi Heating UK Ltd.
Address
Club Street Bamber Bridge Preston Lancaster
Postcode
PR5 6FN

View All Listings by this Company
Manufacturer:
Baxi Spa
Company Name
Baxi Spa
Address
Via Trozzetti 20 36061 Bassano del Grappa (VI)
Country
Italy
Phone
Tel: +39 0424 517 111 Fax: +39 0424 38089

View All Listings by this Company

Print This Approval


#2103013

Water meter incorporating a brass inner body, a plastic outer body and liquid silicone ‘O’-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 50°C.

Section:
1505 Water Meters
Size:
DN15 - 40.
Marking:
Bmeters, serial number and technical information on meter face. Size and flow arrow on water meter body.
Installation Requirements:
R001
Expiry date:
31/03/2026
Model:
Hydrosonic range Sizes: DN15 is available in 110mm, 130mm, 145mm and 165mm lengths. DN20 is available in 130mm and 190mm lengths. DN25 is available in 260mm length only. DN32 is available in 260mm length only. DN40 is available in 300mm length only.
Product Images

Approval Holder:
BMETERS Srl.
Company Name
BMETERS Srl.
Address
Via Friuli No. 3 33050 Gonars (UD) Italy
Phone
+39 0432931415

View All Listings by this Company
Manufacturer:
BMETERS Srl.
Company Name
BMETERS Srl.
Address
Via Friuli No. 3 33050 Gonars (UD) Italy
Phone
+39 0432931415

View All Listings by this Company

Print This Approval


#2201800

Water hammer arrestor with brass body. Maximum working pressure 10.0 bar. Maximum operating temperature 90°C.

Section:
1530 Miscellaneous Fittings
Marking:
RBM on body
Installation Requirements:
R001
Expiry date:
31/03/2026
Model:
SA30720400

Approval Holder:
Intatec Limited
Company Name
Intatec Limited
Address
Airfield Industrial Estate Hixon Staffordshire
Postcode
ST18 0PF
Country
United Kingdom
Phone
01889272180
General Email
ryan.tilsley@intatec.co.uk

View All Listings by this Company
Manufacturer:
RBM S.p.a.
Company Name
RBM S.p.a.
Address
Componenti Per Impianti Idrotermici Via S. Giuseppe, 1 25075 Nave (Brescia)
Country
Italy
General Email

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 63 of 855

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.