Directory Search Results

Print List

#2201055

‘Tornado’ & ‘Ninjo’ ranges of freestanding and undercounter bedpan washers with flow controlled via a solenoid and discharged via type `AB` airgap (verified by test - suitable for backflow protection against fluid category 5). Maximum working pressure 8.0 bar. Maximum operating temperature 60°C

Section:
2360 Washing Machines
Section Subtitle:
Bedpan and disinfecting. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
WRAS Approval Number:
2201055
Note:
Discharge to drain must be via a type AA, AB or AD air gap or in accordance with EN1717.
Size:
Stainless steel braided PEX lined flexible hose assembly incorporating a ½" captive nut end connection.
Marking:
Arjo on door. Model range on control panel.
Installation Requirements:
R001
Expiry date:
31/01/2027
Model:
NINJO range: FD1600 & FD1610 (Free standing) FD1615 (Under counter) TORNADO range: FD1800 & FD1810 (Free standing) FD1805 (Under counter)
Product Images

Approval Holder:
Arjo Huntleigh AB
Company Name
Arjo Huntleigh AB
Address
Hans Michelsensgatan 10 211 20 Malmo

View All Listings by this Company
Manufacturer:
Arjo Huntleigh AB
Company Name
Arjo Huntleigh AB
Address
Hans Michelsensgatan 10 211 20 Malmo

View All Listings by this Company

Print This Approval


#2201031

Range of commercial front loading washing machines with flow controlled by solenoid valve and discharged via a type AD air gap arrangement (verified by test - suitable for backflow protection against fluid category 5). The product is supplied with a single check valve assembly (suitable for backflow protection against Fluid Category 2) and PEX lined rubber inlet connections hoses. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
2370 Washing Machines
Section Subtitle:
Clothes. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
WRAS Approval Number:
2201031
Size:
¾” BSP captive nut (to inlet hoses)
Marking:
ASKO on soap tray.
Installation Requirements:
R001
Expiry date:
31/01/2027
Model:
WMC6742V.T, WMC6742V.T, WMC6763PC.S, WMC6763VC.S, WMC8944PB.T, WMC8944VB.T, WMC8947PI.S, WMC8947VI.S, WMC8943VC.S, WMC8943PC.S.
Product Images

Approval Holder:
Asko Appliances AB
Company Name
Asko Appliances AB
Address
53482 Vara Sweden
Phone
+46 512 320 00

View All Listings by this Company
Manufacturer:
Gorenje gospodinjski aparati, d. o. o.
Company Name
Gorenje gospodinjski aparati, d. o. o.

View All Listings by this Company

Print This Approval


#2201070

Range of commercial front loading washing machines with flow controlled by solenoid valve and discharged via a type AD air gap arrangement (verified by test - suitable for backflow protection against fluid category 5). The product is supplied with a single check valve assembly (suitable for backflow protection against Fluid Category 2) and PEX lined rubber inlet connections hoses. Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
2370 Washing Machines
Section Subtitle:
Clothes. Washing machines in this section will indicate the category of backflow prevention built into each appliance. The location and the use of the washing machine will determine any additional backflow protection that may be required.
WRAS Approval Number:
2201070
Size:
¾” BSP captive nut (to inlet hoses)
Marking:
Alliance CE & company details, model and other information on adhesive label on body
Installation Requirements:
R001
Expiry date:
31/01/2027
Model:
WM75***** C & WM85***** C RANGE OF WASHING MACHINES

Approval Holder:
Alliance Laundry CE s.r.o
Company Name
Alliance Laundry CE s.r.o
Address
Místecká 1116, 742 58 Príbor
Country
Czech Republic
Phone
+420 556 768 885

View All Listings by this Company

Print This Approval


#2109341

Range of UV disinfection units incorporating 316L stainless steel bodies and quartz sleeves. Maximum working pressure 10.0 bar. Maximum operating temperature 35°C.

Section:
2411 Disinfection Equipment
Size:
DN150, DN200, DN250, DN300, DN350 & D400 flanged connections
Marking:
Bio-UV logo, model, date of manufacture (DD/MM/YYYY) and technical information on adhesive label on electrical cabinet. Bio-UV and other technical information on adhesive label on body.
Installation Requirements:
R001 R120 R150 R170 R290 R511
Expiry date:
30/09/2026
Model:
‘IAM’ range of models: IAM2273 300W IAM4273 300W IAM6273 300W IAM4273 400W IAM6273 400W IAM8323 400W IAM6355 800W IAM8406 800W

Approval Holder:
Bio-UV group
Company Name
Bio-UV group
Address
850 avenue Louis Médard Lunel
Postcode
34400
Country
France
Phone
+ 33 (0)4 26 89 98 77
General Email
dedet@bio-uv.com

View All Listings by this Company
Manufacturer:
Bio-UV group
Company Name
Bio-UV group
Address
850 avenue Louis Médard Lunel
Postcode
34400
Country
France
Phone
+ 33 (0)4 26 89 98 77
General Email
dedet@bio-uv.com

View All Listings by this Company

Print This Approval


#2202532

'IUPITAL F10-EW2 NATURAL'. Natural (appears white), injection moulded POM material. For use with water up to 85°C.

Section:
5015 Acetal
Section Subtitle:
Material only. Components made from materials listed in this section may be required to be submitted for audit tests.
WRAS Approval Number:
2202532
Expiry date:
28/02/2027

Approval Holder:
Global Polyacetal Co., Ltd.
Company Name
Global Polyacetal Co., Ltd.
Address
Shiodome Sumitomo-Building 25F 1-9-2, Higashi-shinbashi, Minato Ward, Tokyo 105-0021
Country
Japan

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 591 of 2240

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.