#2010321

Range of spring loaded, resilient trim, in-line check valve cartridges with plastic guide, stem and body with silicone or EPDM 'O'-rings. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C for models 30.4010.0 and 40.4011.0. Maximum operating temperature 60°C for models 30.4043.0 and 30.4094.0.

Section:
0026 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Check Valve Cartridge. The cartridges listed in this section are for factory installation only and are not suitable for on-site installation.
WRAS Approval Number:
2010321
Size:
See model.
Marking:
Flow Arrow, Size and DW (brand of Neoperl) on body. Neoperl logo and WRAS on body (all models except 30.4011.0).
Installation Requirements:
R001
Expiry date:
31/10/2025
Model:
DW10/DN6 30.4010.0 DW11/DN6 30.4011.0 DW15/DN10-GF 30.4043.0 DW15/DN10-PR 30.4094.0
Product Images

Approval Holder:
Neoperl GmbH
Company Name
Neoperl GmbH
Address
Klosterrunstrasse 9-11, Müllheim
Postcode
D-79379
Country
Germany
Phone
+49 7631 188 374
General Email
DE.Approvals@neoperl.com

View All Listings by this Company
Manufacturer:
Neoperl GmbH
Company Name
Neoperl GmbH
Address
Klosterrunstrasse 9-11, Müllheim
Postcode
D-79379
Country
Germany
Phone
+49 7631 188 374
General Email
DE.Approvals@neoperl.com

View All Listings by this Company

Print This Approval


#2010311

Adaptor, with DZR brass body (chrome plated), which incorporates a single check valve cartridge verified by test (as suitable for backflow protection against Fluid Category 2). Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
0030 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Type EB - Non verifiable single check valve.
WRAS Approval Number:
2010311
Size:
½” BSP (F) x ½” BSP (M).
Marking:
Neoperl, flow arrow, size & CR on body.
Installation Requirements:
R001
Expiry date:
31/10/2025
Model:
Adaptor with check valve GX.1353.1.0221
Product Images

Approval Holder:
Neoperl GmbH
Company Name
Neoperl GmbH
Address
Klosterrunstrasse 9-11, Müllheim
Postcode
D-79379
Country
Germany
Phone
+49 7631 188 374
General Email
DE.Approvals@neoperl.com

View All Listings by this Company
Manufacturer:
Neoperl GmbH
Company Name
Neoperl GmbH
Address
Klosterrunstrasse 9-11, Müllheim
Postcode
D-79379
Country
Germany
Phone
+49 7631 188 374
General Email
DE.Approvals@neoperl.com

View All Listings by this Company

Print This Approval


#2010315

Range of non-verifiable double check valve assemblies with DZR brass bodies, incorporating two spring loaded, resilient trim in-line check valve cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
0034 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Type ED - Non-verifiable double check valve.
WRAS Approval Number:
2010315
Size:
See model.
Marking:
V&G, WRAS, Size, DR, flow arrow and date of manufacturer (MM-YY) on body.
Installation Requirements:
R001
Expiry date:
31/10/2025
Model:
12.10172.028.CP5R-8511 – 28mm compression 12.10172.042.CP5R-8511 – 42mm compression
Product Images

Approval Holder:
Zhejiang Valogin Technology Co. Ltd.
Company Name
Zhejiang Valogin Technology Co. Ltd.
Address
Qinggang Technological Ind. Zone, Yuhuan, Zhejiang
Country
China

View All Listings by this Company
Manufacturer:
Zhejiang Valogin Technology Co. Ltd.
Company Name
Zhejiang Valogin Technology Co. Ltd.
Address
Qinggang Technological Ind. Zone, Yuhuan, Zhejiang
Country
China

View All Listings by this Company

Print This Approval


#2010331

Non-verifiable double check valve assembly incorporating DZR brass (chrome plated) body two spring loaded, resilient trim in-line check valve cartridges & a drain port located between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 65°C.

Section:
0034 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Type ED - Non-verifiable double check valve.
WRAS Approval Number:
2010331
Size:
½” BSP (F) x ½” BSP (M).
Marking:
Mira, DCV-H, flow Arrow and CR on body.
Installation Requirements:
R001
Expiry date:
31/10/2025
Model:
1.0.110.55.1 – Mira DCV H Chrome
Product Images

Approval Holder:
Kohler Mira Ltd.
Company Name
Kohler Mira Ltd.
Address
Cromwell Road Cheltenham Gloucestershire
Postcode
GL52 5EP
Country
United Kingdom
Phone
07425 645619
General Email
jon.barfield@mirashowers.com

View All Listings by this Company
Manufacturer:
Kohler Mira Ltd.
Company Name
Kohler Mira Ltd.
Address
Cromwell Road Cheltenham Gloucestershire
Postcode
GL52 5EP
Country
United Kingdom
Phone
07425 645619
General Email
jon.barfield@mirashowers.com

View All Listings by this Company

Print This Approval


#2010372

Range of non verifiable double check valve assemblies consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body. The products incorporate a drain port between the cartridges. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
0034 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Type ED - Non-verifiable double check valve.
WRAS Approval Number:
2010372
Size:
See model
Marking:
Jet range, CR, DN, ED & flow arrow on body.
Installation Requirements:
R001
Expiry date:
31/10/2025
Model:
Jet range comprising of models: K74233 (DN15): ¾” BSP(M) x ½” BSP(F) x 15mm compression. K74234 (DN20): 1” BSP(M) x ¾” BSP(F) x 22mm compression. K74235 (DN25): 1 ¼” BSP (M) x 28mm compression.

Approval Holder:
Wolseley UK Ltd.
Company Name
Wolseley UK Ltd.
Address
2 Kingmaker Court, Warwick Technology Park, Warwick
Postcode
CV34 6DY
Country
United Kingdom
Phone
01926705792
General Email
martin.lister@wolseley.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 39 of 2261

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.