Section Code 0684 : Tap(s) with a non-touch methods of flow control and a single inlet.
Back To Directory SectionsRange of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). Flow is controlled with a solenoid valve activated via touch operation. The spout outlets incorporate plastic aerators and the flexible hoses incorporate a stainless-steel strainer. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C
Range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). Flow is controlled with a solenoid valve activated via touch operation. Temperature is controlled using a manual single lever operating member. The spout outlets incorporate plastic aerators. The inlets incorporate an approved check valve cartridge; however the complete assemblies have not been fully tested to demonstrate they provide backflow protection, and a stainless steel strainer. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (fixed) electronically controlled tap assemblies. Incorporating a solenoid valve activated via an infra-red sensor. The inlets to the control box incorporate stainless steel strainers and the outlet incorporates a plastic aerator. Maximum working pressure: 8 Bar Maximum operating temperature: 65°C
Range of single hole, single outlet (fixed) electronically controlled tap assemblies. Incorporating a solenoid valve activated via an infra-red sensor. The inlets to the control box incorporate stainless steel strainers and the outlet incorporates a plastic aerator. Maximum working pressure: 8 Bar Maximum operating temperature: 65°C
Range of wall mounted, two-hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). The flow is controlled by a solenoid valve activated via infra-red sensor. Temperature is controlled independently via a thermostatic cartridge with a dome operating member which incorporates a manual override button. The spout outlets incorporate plastic aerators, and both inlets incorporate an approved single check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection) and stainless-steel strainers. Maximum working pressure 10.0 Bar. Maximum operating temperature 60.0°C.
Page 35 of 39
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.