Directory Search Results

Print List

#2104902

BS EN 997:2018 RAK Compact Rimless Wall Hung 700mm COMRIMWH W.C. pan (Ceramic), Thomas Dudley ‘A’ frame incorporating a Thomas Dudley Vantage Concealed cistern with a side entry compact type float operated inlet valve which discharges via a Type AG airgap and a dual flush pneumatic drop valve capable of full flush volumes of 4.5 litres and a reduced flush of 3 litres. The inlet connection hose incorporates a servicing valve. Maximum working pressure 10.0 bar. Cold water use only.

Section:
2041 WC suites
Section Subtitle:
Low level WC incorporating a Type AUK1 air gap backflow prevention arrangement. The product incorporates a fluid category 5 backflow prevention arrangement.
WRAS Approval Number:
2104902
Size:
15mm Push-fit Inlet connection.
Marking:
Inspection covers marked Thomas Dudley Ltd. Top of outlet drop valve marked ‘TD’, Corner of wall hung pan marked ‘RAK CERAMICS’
Installation Requirements:
R001 R559
Expiry date:
30/04/2026
Model:
RAK Compact Rimless Wall Hung 700mm COMRIMWH W.C. pan and Thomas Dudley Illusion A or Illusion Compact Universal Frame

Approval Holder:
Ruddy Joinery & Fit-Out Specialists
Company Name
Ruddy Joinery & Fit-Out Specialists
Postcode
MK45 5BS

View All Listings by this Company

Print This Approval


#2304110

Undercounter boiling water cistern with a stainless steel body, stainless steel element and silicone ‘O’-rings and gaskets. Maximum working pressure 8.0 bar. Maximum operating temperature 95°C.

Section:
0060 Boilers
Section Subtitle:
Catering, Feed Cistern or Pressure.
WRAS Approval Number:
2304110
Size:
Stainless steel braided PEX lined flexible hose assembly with ½" captive nut end connection.
Marking:
ABI INTERIORS LOGO on front cover, Model number & product info on adhesive label on body
Installation Requirements:
R001 R009 R170 R040
Expiry date:
30/04/2028
Model:
17450

Approval Holder:
ABI Interiors International LTD
Company Name
ABI Interiors International LTD
Address
10 John Street London
Postcode
WC1N 2EB
Country
United Kingdom
Phone
02045 389222
General Email
robert.b@abiinteriors.com

View All Listings by this Company

Print This Approval


#250902707

‘TankBoost’ range of cold-water storage cisterns, incorporating a float operated inlet valve. The C5 suffix models incorporate a Type ‘AB’ air gap with a meshed weir overflow (verified by test - suitable for backflow protection against Fluid Category 5). Cisterns with SUB in the model code incorporate a submersible pump and an expansion vessel. All models incorporate a screened warning pipe and dip tube. Models without a C5 suffix also incorporate a screened breather. Maximum working pressure 10.0 bar. Cold water use only.

Section:
0120 Cisterns Storing Water for Domestic Purposes
Section Subtitle:
Drinking, washing, cooking and sanitary. Cisterns in this section comprise units, which, where detailed, include all the essential items identified in Schedule 2. Paragraph 16(4), of the Water Supply (Water Fittings) Regulations 1999. Where these items are not detailed in the directory entry, these will need to be included at point of installation, in order to fully comply with Schedule 2. Paragraph 16(4), of the Water Supply (Water Fittings) Regulations 1999.
WRAS Approval Number:
250902707
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M).
Marking:
Salamander pumps and salamander logo on body. Salamander pumps, model number (which indicates capacity), product information and serial number on adhesive label on body.
Installation Requirements:
R001 R008 R415 R574
Expiry date:
30/09/2030
Model:
TNK-100-SUB, TNK-200-SUB, TNK-350-SUB, TNK-450-SUB, TNK-100, TNK-200, TNK-350, TNK-450. Type ‘AB’ air gap models: TNK-100-SUBC5, TNK-200-SUBC5, TNK-350-SUBC5, TNK-450-SUBC5, TNK-100-C5, TNK-200-C5, TNK-350-C5, TNK-450-C5. Where: 100, 200, 350, 450 indicates the stored volume of water in the tank in litres. SUB indicates that the unit includes a submersible pump for boosting the stored water in the tank. C5 indicates a CAT5 variant of the unit.

Approval Holder:
Salamander Pumps
Company Name
Salamander Pumps
Postcode
SR5 3XE
Country
United Kingdom
Phone
0191 535 4528
General Email
lewisw@salamanderpumps.co.uk

View All Listings by this Company
Manufacturer:
Salamander Pumps
Company Name
Salamander Pumps
Postcode
SR5 3XE
Country
United Kingdom
Phone
0191 535 4528
General Email
lewisw@salamanderpumps.co.uk

View All Listings by this Company

Print This Approval


#250902723

‘TankBoost 5 bar’ range of cold-water storage cisterns, incorporating a float operated inlet valve. The C5 suffix models incorporate a Type ‘AB’ air gap with a meshed weir overflow (verified by test - suitable for backflow protection against Fluid Category 5). Cisterns with SUB in the model code incorporate a submersible pump and an expansion vessel. All models incorporate a screened warning pipe and dip tube. Models without a C5 suffix also incorporate a screened breather. Maximum working pressure 10.0 bar. Cold water use only.

Section:
0120 Cisterns Storing Water for Domestic Purposes
Section Subtitle:
Drinking, washing, cooking and sanitary. Cisterns in this section comprise units, which, where detailed, include all the essential items identified in Schedule 2. Paragraph 16(4), of the Water Supply (Water Fittings) Regulations 1999. Where these items are not detailed in the directory entry, these will need to be included at point of installation, in order to fully comply with Schedule 2. Paragraph 16(4), of the Water Supply (Water Fittings) Regulations 1999.
WRAS Approval Number:
250902723
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (M).
Marking:
Salamander pumps and salamander logo on body. Salamander pumps, model number (which indicates capacity), product information and serial number on adhesive label on body.
Installation Requirements:
R001 R008 R415 R574
Expiry date:
30/09/2030
Model:
TNK5-200-SUB, TNK5-350-SUB, TNK5-450-SUB. Type ‘AB’ air gap models: TNK5-200-SUBC5, TNK5-350-SUBC5, TNK5-450-SUBC5. Where: 200, 350, 450 indicates the stored volume of water in the tank in litres. SUB indicates that the unit includes a submersible pump for boosting the stored water in the tank.

Approval Holder:
Salamander Pumps
Company Name
Salamander Pumps
Postcode
SR5 3XE
Country
United Kingdom
Phone
0191 535 4528
General Email
lewisw@salamanderpumps.co.uk

View All Listings by this Company
Manufacturer:
Salamander Pumps
Company Name
Salamander Pumps
Postcode
SR5 3XE
Country
United Kingdom
Phone
0191 535 4528
General Email
lewisw@salamanderpumps.co.uk

View All Listings by this Company
Manufacturer:
Salamander Pumps
Company Name
Salamander Pumps
Postcode
SR5 3XE
Country
United Kingdom
Phone
0191 535 4528
General Email
lewisw@salamanderpumps.co.uk

View All Listings by this Company

Print This Approval


#241004050

DAB range of one piece, pre-insulated cold water storage cisterns and covers for domestic water storage, supplied with a wholesome water kit. The cisterns walls are available in grey, blue, green, white, red and anthracite grey (external) colours and the cistern base is straw coloured. For cold water use only. From November 2024 the water contact layer of the cistern base and walls is available in grey or straw colours. The outer layer of the cistern base is available in blue, green, white, red and anthracite grey colours.

Section:
0120 Cisterns Storing Water for Domestic Purposes
Section Subtitle:
Drinking, washing, cooking and sanitary. Cisterns in this section comprise units, which, where detailed, include all the essential items identified in Schedule 2. Paragraph 16(4), of the Water Supply (Water Fittings) Regulations 1999. Where these items are not detailed in the directory entry, these will need to be included at point of installation, in order to fully comply with Schedule 2. Paragraph 16(4), of the Water Supply (Water Fittings) Regulations 1999.
WRAS Approval Number:
241004050
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
20 litres – 42,000 litres.
Marking:
DAB, serial number & nominal capacity on adhesive label on body.
Installation Requirements:
R001 R270 R280
Expiry date:
31/10/2029
Model:
DAB Esytank DAB Excell Tank

Approval Holder:
DAB Pumps
Company Name
DAB Pumps
Address
Severalls Business Park 6 Gilberd CT Highwoods Colchester
Postcode
CO4 9WN
Country
United Kingdom

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 34 of 41

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.