Heaters

Section Code 1465 : Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.

Back To Directory Sections

#2306060

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with a temporary filling loop which incorporates a combined isolation valve and double check valve assembly (suitable for backflow protection against Fluid Category 3), stainless steel braided EPDM lined flexible hose assembly and an isolation valve. The secondary circuit (DHW) incorporates a stainless-steel strainer. The primary circuit incorporates isolation valves on the flow and return. Maximum working pressures: DHW: 10.0 Bar CH:2.5 Bar Maximum operating Temperatures: DHW: 65.0°C CH: 85.0°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2306060
Size:
DHW: 15mm compression CH: 22mm compression
Marking:
Vailant on front cover. Vailant, Model,Pressure, Temperature and other information on adhesive label on rear of body
Installation Requirements:
R001 R140 R360
Expiry date:
30/06/2028
Model:
VUW 20/26CS/1-5 (N-GB) ecoTEC plus 826 VUW 25/32CS/1-5 (N-GB) ecoTEC plus 832 VUW 30/36CS/1-5 (N-GB) ecoTEC plus 836 VUW 30/40CS/1-5 (N-GB) ecoTEC plus 840 VUI 30/40CS/1-5 (N-GB) ecoTEC plus 940

Approval Holder:
Vaillant GmbH
Company Name
Vaillant GmbH
Address
Berghauser Strasse, 40 D-42859 Remscheid
Country
Germany
Phone
Tel: +49 2191 182126

View All Listings by this Company
Manufacturer:
Vaillant Industrial UK Ltd
Company Name
Vaillant Industrial UK Ltd
Address
Nottingham Road Belper Derbyshire
Postcode
DE56 1JT
Phone
01773 824141

View All Listings by this Company

Print This Approval


#2309044

Range of wall mounted combination boilers providing domestic hot water via a heat exchanger and pressurised central heating system. The products can be supplied with a rigid or flexible filling loop or keyless filling link. The flexible and rigid filling loops incorporate a flexible hose or copper pipe, isolation valve, double check valve assembly (suitable for back flow protection against fluid category 3). The keyless filling link incorporates a CAB backflow prevention device (suitable for back flow protection against fluid category 3). The products also incorporate an expansion vessel and pressure relief valve set at 3.0 bar. Maximum working pressure of primary circuit 2.5 bar. Maximum operating temperature of primary circuit 85°C Maximum working pressure of secondary circuit 8.0 bar Maximum operating temperature of secondary circuit 60°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2309044
Note:
When installing the keyless filling link, the discharge from the relief outlet port of this fitting must be made via a type AA, AB or AD air gap, or in accordance with EN 1717.
Size:
¾” BSP (M) (primary circuit). ½” BSP (M) (secondary circuit).
Marking:
Baxi on front cover.
Installation Requirements:
R001 R140 R360
Expiry date:
30/09/2028
Model:
7796586 BAXI 624 COMBI 2 7796587 BAXI 630 COMBI 2 7796588 BAXI 636 COMBI 2 7813609 BAXI 624 COMBI LPG 2 7814304 BAXI 824 COMBI 2 7814305 BAXI 830 COMBI 2 7814306 BAXI 836 COMBI 2 7814307 BAXI 830 COMBI LPG 2 7814308 BAXI 836 COMBI LPG 2 7814309 BAXI ASSURE 524 COMBI 2 7814310 BAXI ASSURE 530 COMBI 2 7814311 BAXI ASSURE 536 COMBI 2 7814312 BAXI ASSURE 530 COMBI LPG 2

Approval Holder:
Baxi Heating UK Limited
Company Name
Baxi Heating UK Limited
Address
Brooks House, Coventry Road, Warwick
Postcode
CV34 3LL

View All Listings by this Company

Print This Approval


#2309313

‘SATK 32’ range of indirect heat interface units providing instantaneous hot water. Domestic hot water is provided via a plate heat exchanger and this circuit incorporates a flow detector, stainless-steel filter and water hammer arrestor. The primary/space heating circuit incorporates a pressure relief valve set at 2.5 bar and an expansion vessel. Maximum working pressure of the domestic hot water circuit is 10.0 bar. Maximum working pressure of the primary circuit is 16.0 bar. Maximum working pressure of the space heating circuit is 2.5 bar. Maximum operating temperature 90°C.

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2309313
Size:
¾” BSP (M).
Marking:
Caleffi and Caleffi logo moulded on face of unit. Caleffi, Caleffi logo, model number and technical info on data plate inside unit.
Installation Requirements:
R001 R140 R360
Expiry date:
30/09/2028
Model:
SATK32103 - Wall-mounted Indirect Heat Interface Unit for Instantaneous domestic hot water production – DHW capacity 50kW. SATK32105 - Wall-mounted Indirect Heat Interface Unit for Instantaneous domestic hot water production – DHW capacity 60kW. SATK32107 - Wall-mounted Indirect Heat Interface Unit for Instantaneous domestic hot water production – DHW capacity 75kW.

Approval Holder:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
Strada Regionale 229 n. 25 Fontaneto d'Agogna (NO)
Postcode
28010
Country
Italy
Phone
+39 0322 8491
General Email
gary.perry@caleffi.com

View All Listings by this Company
Manufacturer:
Caleffi S.p.A
Company Name
Caleffi S.p.A
Address
Strada Regionale 229 n. 25 Fontaneto d'Agogna (NO)
Postcode
28010
Country
Italy
Phone
+39 0322 8491
General Email
gary.perry@caleffi.com

View All Listings by this Company

Print This Approval


#2402803

Range of wall mounted, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel, pressure relief valve set at 3.0 bar and flow regulators. The inlets to both domestic hot water and primary circuits are controlled via screwdriver operated angled spherical valve. The primary circuit can be filled via a built in CAB device, that has been verified by test (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 80°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2402803
Note:
The discharge from the relief outlet port of the CAB device must be made via a type AA, AB or AD air gap, or in accordance with EN 1717. Claims of flow rate are made by the manufacturer and not considered part of the listing.
Size:
22mm Compression Primary 15mm Compression Secondary
Marking:
Worcester on label on the front panel. Serial number, model numbers and other technical information on adhesive labels on body and underside of the unit
Installation Requirements:
R001
Expiry date:
28/02/2029
Model:
Worcester Greenstar 8000 Style GR8700iW 30 C - Gas combi boiler 30kw, 14 plate heat exchanger 111/min, Worcester Greenstar 8000 Style GR8700iW 35 C - Gas combi boiler 35kw, 16 plate heat exchanger 131/min, Worcester Greenstar 8000 Style GR8700iW 40 C - Gas combi boiler 40kw, 18 plate heat exchanger 141/min, Worcester Greenstar 8000 Style GR8700iW 45 C - Gas combi boiler 45kw, 18 plate heat exchanger 151/min, Worcester Greenstar 8000 Style GR8700iW 50 C - Gas combi boiler 50kw, 20 plate heat exchanger 151/min. Worcester Greenstar 8000 Life GR8300iW 30 C - Gas combi boiler 30kw, 14 plate heat exchanger 111/min, Worcester Greenstar 8000 Life GR8300iW 35 C - Gas combi boiler 35kw, 16 plate heat exchanger 131/min, Worcester Greenstar 8000 Life GR8300iW 40 C - Gas combi boiler 40kw, 18 plate heat exchanger 141/min, Worcester Greenstar 8000 Life GR8300iW 45 C - Gas combi boiler 45kw, 18 plate heat exchanger 151/min, Worcester Greenstar 8000 Life GR8300iW 50 C - Gas combi boiler 50kw, 20 plate heat exchanger 151/min. Models added September 2024 Worcester Greenstar 8000+ GR8701iW 32 CB - Gas combi boiler 32kW, 16 plate heat exchanger 13 l/min Worcester Greenstar 8000+ GR8701iW 36 CB - Gas combi boiler 36kW, 16 plate heat exchanger 14 l/min Worcester Greenstar 8000+ GR8701iW 32 C - Gas combi boiler 32kW, 16 plate heat exchanger 13 l/min Worcester Greenstar 8000+ GR8701iW 36 C - Gas combi boiler 36kW, 16 plate heat exchanger 14 l/min Worcester Greenstar 8000+ GR8701iW 40 C - Gas combi boiler 40kW, 18 plate heat exchanger 15 l/min Worcester Greenstar 8000+ GR8701iW 45 C - Gas combi boiler 45kW, 18 plate heat exchanger 18 l/min Worcester Greenstar 8000+ GR8701iW 50 C - Gas combi boiler 50kW, 20 plate heat exchanger 21 l/min

Approval Holder:
Worcester Bosch
Company Name
Worcester Bosch
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
+44 1905 752761
General Email
ian.sharp@uk.bosch.com

View All Listings by this Company

Print This Approval


#240202716

Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system. The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel filter. The primary and secondary circuit incorporates isolation valves on the flow and the primary also has one on the return. Maximum working pressures: Secondary DHW: 10.0 Bar Primary CH: 2.5 Bar Maximum operating temperatures: Secondary DHW: 65.0°C Primary CH: 85.0°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
240202716
Size:
DHW: 22mm compression. CH: 22mm compression
Marking:
Vaillant logo, serial number, CE, pressure and other technical information on adhesive label on bottom of unit
Installation Requirements:
R001 R140 R360
Expiry date:
28/02/2029
Model:
0010019980 – VUW 246/7-2 (H-GB) ecoTec sustain 24 0010019981 – VUW 286/7-2 (H-GB) ecoTec sustain 28 0010019982 – VUW 346/7-2 (H-GB) ecoTec sustain 34

Approval Holder:
Vaillant GmbH
Company Name
Vaillant GmbH
Address
Berghauser Strasse, 40 D-42859 Remscheid
Country
Germany
Phone
Tel: +49 2191 182126

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 4 of 6

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.