Heaters

Section Code 1465 : Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.

Back To Directory Sections

#2107804

Ranges of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system incorporating an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. Products are supplied with a rigid filling loop or keyless filling link. Maximum working pressure of the primary circuit is 2.5 bar & maximum supply pressure of the secondary circuit is 8.0 bar. Cold water supply only. Maximum operating temperature 95°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2107804
Expiry date:
31/07/2026
Note:
The rigid filling loop assembly incorporates a double check valve assembly (verified by test as suitable for backflow protection against fluid category 3). The keyless filling link incorporates a CAB backflow prevention device (verified by test as suitable for backflow protection against fluid category 3). The discharge from the relief outlet port of this device must be made via a type AA, AB or AD air gap, or in accordance with EN 1717.
Size:
Primary: 28mm compression. Secondary: 15mm compression.
Marking:
Baxi on front of boiler.
Installation Requirements:
R001 R140 R360
Model:
Baxi 224 Combi (product code 7656160). Baxi 228 Combi (7656161). Baxi 424 Combi (7656162). Baxi 428 Combi (7656163). Baxi 428 Combi LPG (7676760).
Factor:
Baxi Heating UK Ltd.
Company Name
Baxi Heating UK Ltd.
Address
Club Street Bamber Bridge Preston Lancaster
Postcode
PR5 6FN

View All Listings by this Company
Manufacturer:
Baxi Spa
Company Name
Baxi Spa
Address
Via Trozzetti 20 36061 Bassano del Grappa (VI)
Country
Italy
Phone
Tel: +39 0424 517 111 Fax: +39 0424 38089

View All Listings by this Company

Print This Approval


#2111311

Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger. The pressurised central heating system incorporates an expansion vessel and pressure relief valve set at 3.0 bar. The supplies to both domestic hot water and primary are controlled via spherical valves. The primary circuit has a maximum working pressure of 2.5 bar. The secondary circuit has maximum working pressure of 10.0 bar. Maximum supply temperature is 60°C. Maximum operating temperature of secondary circuit is 85°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2111311
Expiry date:
30/11/2026
Size:
Primary: 22mm compression inlet/outlet. Secondary: 15mm compression.
Marking:
Worcester and Worcester logo on front of boiler.
Installation Requirements:
R001
Model:
7-733-600-371: Greenstar 4000 25 Combi NG. 7-733-600-372: Greenstar 4000 25 Combi LPG. 7-733-600-373: Greenstar 4000 30 Combi NG. 7-733-600-374: Greenstar 4000 30 Combi LPG.
Factor:
Bosch Thermotechnology Ltd.
Company Name
Bosch Thermotechnology Ltd.
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
0844 892 9900

View All Listings by this Company
Manufacturer:
Bosch Thermotechnology Ltd. Bosch Thermotechnik GmbH. Bosck Termoteknik Sanayu ve Ticaret A.S.
Company Name
Bosch Thermotechnology Ltd. Bosch Thermotechnik GmbH. Bosck Termoteknik Sanayu ve Ticaret A.S.
Address

View All Listings by this Company

Print This Approval


#2111349

Range of floor standing gas fired combination boilers providing domestic hot water via a stainless-steel plate heat exchanger. Unit is supplied with a safety relief valve (8.0 bar). Maximum working pressure 7.5 bar. Maximum operating temperature 85°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2111349
Expiry date:
30/11/2026
Size:
2 ½” BSP (M)
Marking:
Eco Heating Systems Senator+ on front casing.
Installation Requirements:
R001 R140 R360
Model:
Senator 400 WW Senator 500 WW
Manufacturer:
Eco Heating Systems B/V
Company Name
Eco Heating Systems B/V
Address
Rigaweg 10, 9723 TH Groningen
Country
Netherlands
Phone
+31 6 86823847

View All Listings by this Company

Print This Approval


#2110320

Range of wall hung, gas-fired condensing combination boilers providing domestic hot water via a plate heat exchanger and pressure relief valve set at 3.0 bar. The supplies to both primary hot water and secondary are controlled via spherical valves. The boilers incorporate a filling loop assembly which incorporates a double check valve assembly (suitable for backflow protection against Fluid Category 3). Primary circuit: Maximum working pressure 2.5 bar. Maximum operating temperature 82°C. Secondary circuit: Maximum working pressure 10.0 bar. Maximum operating temperature 60°C

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2110320
Expiry date:
31/10/2026
Size:
22mm compression
Marking:
Worcester (brand of Bosch) on front of boiler. Worcester, address, model, serial No. & other tech info on adhesive label on inside of panel.
Installation Requirements:
R001
Model:
Greenstar Highflow range comprising of model numbers: 7 731 600 098 (model code: 440CDi ErP). 7 731 600 099 (440CDi ErP). 7 731 600 100 (550CDi ErP). 7 731 600 101 (550CDi ERP).
Manufacturer:
Bosch Thermotechnology Ltd.
Company Name
Bosch Thermotechnology Ltd.
Address
Cotswold Way Warndon Worcester
Postcode
WR4 9SW
Country
United Kingdom
Phone
0844 892 9900

View All Listings by this Company

Print This Approval


#2111371

Range of floor standing gas fired combination boilers providing domestic hot water via a stainless-steel plate heat exchanger. Unit is supplied with a safety relief valve (8.0 bar). Maximum working pressure 7.5 bar. Maximum operating temperature 85°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2111371
Expiry date:
30/11/2026
Size:
2 ½” BSP (M)
Marking:
Lochinvar on front casing. Lochinvar , model & serial number on adhesive label on body
Installation Requirements:
R001 R140 R360
Model:
TTW410 & TTW580 FLOOR STANDING GAS FIRED COMBINATION BOILERS
Factor:
Lochinvar Ltd.
Company Name
Lochinvar Ltd.
Address
7 Lombard Way The MXL Centre Banbury
Postcode
OX16 4TJ
Country
Oxon
Phone
+44 (0) 1295 269981
General Email
general@lochinvar.ltd.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 4 of 8

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.