Range of flow sensors with or without brass bodies. Maximum working pressure 16.0 bar. Maximum operating temperature 90°C.
Range of valves intended to be used as part of a filling loop. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.
Range of single and doubled sphered rubbered expansion bellows incorporating a variety of flanged end connections. Style 99 TUF also incorporates a threaded inlet connection. Maximum working pressure 16.0 Bar Model (99 SSHDC) Maximum working pressure 20.0 Bar Cold water use only.
Range of pumps, single and 4-stage, with stainless steel bodies and plastic impellers. The pumps are housed within a plastic casing. The outlets of the WGZ15-20EA, WGZ15-45EA and WGZ15-45EAB models incorporate a non-return valve. The WGZ15-35EA.and WGZ15-35EAB models have a twin pump arrangement which incorporates a non-return valve within the connecting pipe between the pumps. Maximum working pressure 10.0 Bar. Maximum operating temperature 95°C.
Range of circulation pumps with a stainless steel body, plastic impeller and a silicone ‘O’-ring. Maximum working pressure 10.0 bar. Maximum operating temperature 95°C.
Range of multistage centrifugal pumps, with stainless steel bodies (CRN models) or black coloured cataphoretic electrodeposition coated cast iron bodies (CR models), stainless steel sleeve and impellers. The products can be supplied with or without a sensor. Maximum working pressures (no. of stages in brackets): CR/CRN 95 (1-5): 16.0 bar. CR/CRN 95 (6-8): 25.0 bar. CRN 95 (9-12): 40.0 bar. CR/CRN 125 (1-4): 16.0 bar. CR 125 (5): 25.0 bar. CRN 125 (6-7): 25.0 bar. CRN 125 (8-12): 40.0 bar. CR 155 (1-4): 16.0 bar. CRN 155 (1-4): 16.0 bar. CRN 155 (5-6): 25.0 bar. CRN 155 (7-11): 40.0 bar. CR/CRN 185 (1-3): 16.0 bar. CR/CRN 185 (4-5): 25.0 bar. CR/CRN 185 (6-8): 40.0 bar. CR/CRN 215 (1-3): 16.0 bar. CR/CRN 215 (4-5): 25.0 bar. CR/CRN 215 (6-7): 40.0 bar. CR/CRN 255 (1-3): 16.0 bar. CR/CRN 255 (3-4): 25.0 bar. CR/CRN 255 (5-6): 40.0 bar. When a sensor is incorporated the maximum working pressure is as follows: 25.0 bar with either the IPS44 or VTU sensor, (unless they are used on a pump with a maximum working pressure of 16.0 bar, in this instance the lesser pressure applies). The MBS3000 sensor can be used on all models, the pump maximum working pressure applies. Cold water use only.
Range of shower outlets with brass bodies (various finishes). The products incorporate a stainless-steel strainer and flow regulator. Open outlet use.
Range of overhead shower outlets with (chromium plated - brass bodies). The inlets incorporate a stainless-steel strainer and flow regulator. Model FLS-8120 Incorporates a shower arm.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower handsets and shower kits with chromium plated ABS bodies. Some models incorporate a shower hose.
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall mounted shower panels. The flow is controlled via a solenoid valve which is operated via an infrared sensor located at the bottom of the panel. Maximum working pressure 5.0 bar.
Non-metallic materials and components comply with BS6920 at 60°C
Range of shower outlet elbows with chrome plated brass bodies. The inlet incorporates a single check valve cartridge however, the complete product has not been fully tested to demonstrate It provides backflow protection. Open Outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of overhead shower outlets with chromium plated plastic bodies. The inlets incorporate combined EPDM washers and stainless-steel strainers. Open outlet use only.
Non-metallic materials and components comply with BS6920 at 60°C
Range of wall mounted shower arms, (brass bodies - various finishes) incorporating EPDM ‘O’- rings.
Non-metallic materials and components comply with BS6920 at 85°C
Range of wall mounted, overhead shower outlets with brass bodies (chromium plated), EPDM o-rings, fibre gasket and strainer at the shower head inlets. Multiple spray patterns available which is controlled via solenoid valve and a touch sensor. Product incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. Open outlet use only. Maximum working temperature 60°C.
Range of shower sets consisting of a chrome plated ABS plastic shower handset, PVC lined shower hoses that incorporate stainless-steel strainers and riser rail assemblies. Maximum operating temperature 60 °C.
Range of wall mounted shower arms (stainless steel bodies - various finishes). Maximum operating temperature 100 °C
Range of shower arms, (brass bodies – various finishes).
Non-metallic materials and components comply with BS6920 at 65°C
Range of shower handsets, (plastic bodies - various plated finishes). All models incorporate a flow regulator on the inlets. Maximum operating temperature 60°C
Non-metallic materials and components comply with BS6920 at 60°C
Range of ‘Y’ Strainers with blue epoxy coated ductile iron bodies, incorporating a stainless-steel mesh. Maximum working pressure 16.0 Bar
Non-metallic materials and components comply with BS6920 at 85°C
Flow switch with a black plastic (nylon) body and an EPDM ‘O’-ring. The product incorporates a plastic filter on the inlet. Maximum working pressure 10.0 bar.
Non-metallic materials and components comply with BS6920 at 85°C
Page 273 of 509
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.