Section Code 1505 : Meters in this section have been judged only against the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009, and have not been checked for accuracy by the Scheme.
Back To Directory SectionsRange of water meters with brass bodies Maximum operating pressure 16 bar. Cold water use only.
Range of ultrasonic water meters models U-WR have brass bodies and models U-WR2 have plastic bodies. The inlets incorporate a plastic strainer. Maximum working pressure 16.0 bar. Maximum operating temperature 50⁰C.
Range of water meters with cast iron bodies (blue epoxy coating) and EPDM ‘O’ rings. Maximum working pressure 16.0 Bar Maximum operating temperature 23.0°C
Range of water meters with brass bodies and plastic turbines. The inlet incorporates a plastic filter. Maximum working pressure 16.0 bar. Maximum operating temperatures Sizes DN15-25 models: 50°C, sizes DN32-40 models: 85°C.
Range of water meters with either cast iron (blue epoxy coated) or stainless-steel bodies, transducers and EPDM rubber O-rings. Maximum working pressure 25.0 Bar. Maximum operating temperature 50.0°C.
Page 25 of 34
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.