Directory Search Results

Print List

#240704008

Concealed, floor mounted basic set with DZR brass body. For use with floor standing combination tap assemblies. Maximum operating pressure 10 bar. Maximum operating temperature 70°C

Section:
1535 Miscellaneous
Section Subtitle:
Tap accessories.
WRAS Approval Number:
240704008
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
½” BSP (F)
Marking:
Hansgrohe & DR
Installation Requirements:
R001 R010
Expiry date:
31/07/2029
Model:
10452180
Product Images

Approval Holder:
Hansgrohe SE
Company Name
Hansgrohe SE
Address
Auestrasse 5 - 9, Schiltach
Postcode
77761
Country
Germany
Phone
+49 170 4471 718
General Email
Ludovic.hauer@hansgrohe.com

View All Listings by this Company
Manufacturer:
Hansgrohe SE
Company Name
Hansgrohe SE
Address
Auestrasse 5 - 9, Schiltach
Postcode
77761
Country
Germany
Phone
+49 170 4471 718
General Email
Ludovic.hauer@hansgrohe.com

View All Listings by this Company

Print This Approval


#240702708

Range of click type pop-up wastes (brass or plastic bodies - various finishes, see model).

Section:
1535 Miscellaneous
Section Subtitle:
Tap accessories.
WRAS Approval Number:
240702708
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1¼” BSP (M).
Marking:
ISI on body
Installation Requirements:
R001
Expiry date:
31/07/2029
Model:
Plastic body: S8803XX, B952298XX Brass body: E1482XX, B953262XX Where XX denotes finish and can be replace by: All models: AA = Chrome. B953262XX model only: A2 = Brushed Gold, A5 = Magnetic Grey, GN = Silver Storm, XG = Silk Black.
Product Images

Approval Holder:
Ideal Standard (UK) Ltd
Company Name
Ideal Standard (UK) Ltd
Address
Old Road (Lodge 1) Armitage, Rugeley, Staffordshire
Postcode
WS15 4BT
Country
United Kingdom
General Email
tyeomans@idealstandard.co.uk

View All Listings by this Company

Print This Approval


#240703004

Surface mounting kit for a mono block sink mixer with stainless steel braided EPDM lined flexible hose assemblies with ½” BSP captive nut end connections. The product is supplied with a 15x15mm compression isolation valves that incorporate single check valve cartridges, however, the complete assembly has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
1535 Miscellaneous
Section Subtitle:
Tap accessories.
WRAS Approval Number:
240703004
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
15mm Compression
Marking:
BRISTAN on the face of the base
Installation Requirements:
R001
Expiry date:
31/07/2029
Model:
EF KIT PK
Product Images

Approval Holder:
Bristan Group Ltd.
Company Name
Bristan Group Ltd.
Address
Birch Coppice Business Park Dorden Tamworth
Postcode
B78 1SG
Country
Staffs
Phone
01827 254144
General Email
hmistry@bristan.com

View All Listings by this Company

Print This Approval


#240707001

‘Hydro MPC’ range of booster sets incorporating vertical multistage centrifugal pumps, butterfly valves, non-return valves (not suitable for backflow protection), pressure transmitters, pressure gauges, lever operated spherical valves, stainless steel blanking flanges and fibre/NBR gaskets. Maximum working pressure 16.0 bar. Cold water use only. ‘Hydro MPC’ range of booster sets incorporating vertical multistage centrifugal pumps, butterfly valves, non-return valves (not suitable for backflow protection), pressure transmitters, pressure gauges, lever operated spherical valves, stainless steel blanking flanges and fibre/NBR gaskets. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240707001
Note:
Approval doesn’t include pressure vessels.
Size:
Small Booster Sets Systems with 2 to 3 Pumps = 2” BSP (M), Systems with 4 to 6 pumps = 2½” BSP (M). Medium Booster Sets Systems with CRI(E)10 pumps: Systems with 2 to 3 pumps = 2½” BSP (M), Systems with 4 to 5 pumps = DN80 flanges, Systems with 6 pumps = DN100 flanges. Systems with CRI(E)15 and CRI(E)20 pumps: Systems with 2 pumps = DN80 flanges, Systems with 3 to 4 pumps = DN100 flanges, Systems with 5 to 6 pumps = DN150 flanges. Sizes added November 2024: Large Booster Sets Systems with CR(E)32 pumps: Systems with 2 pumps = DN100 flanges, Systems with 3 to 6 pumps = DN150 flanges. Systems with CR(E)45 and CR(E)64 pumps: Systems with 2 pumps = DN150 flanges, Systems with 3 to 6 pumps = DN200 flanges.
Marking:
Grundfos logo, model, serial number, P/N, manufacturing country and technical information on adhesive label on base frame.
Installation Requirements:
R001 R008 R415
Expiry date:
31/07/2029
Model:
Small Booster Sets (PN16): HYDRO MPC-E “X” CRIE3, HYDRO MPC-E “X” CRIE5, HYDRO MPC-F “X” CRI3, HYDRO MPC-F “X” CRI5, HYDRO MPC-S “X” CRI3, HYDRO MPC-S “X” CRI5. Medium Booster Sets (PN16): HYDRO MPC-E “X” CRIE10, HYDRO MPC-E “X” CRIE15, HYDRO MPC-E “X” CRIE20, HYDRO MPC-F “X” CRI10, HYDRO MPC-F “X” CRI15, HYDRO MPC-F “X” CRI20, HYDRO MPC-S “X” CRI10, HYDRO MPC-S “X” CRI15, HYDRO MPC-S “X” CRI20. Models added November 2024: Large Booster Sets (PN16): HYDRO MPC-E “X” CRE32, HYDRO MPC-E “X” CRE45, HYDRO MPC-E “X” CRE64, HYDRO MPC-F “X” CR32, HYDRO MPC-F “X” CR45, HYDRO MPC-F “X” CR64, HYDRO MPC-S “X” CR32, HYDRO MPC-S “X” CR45, HYDRO MPC-S “X” CR64. The “X” preceding CR indicates the number of pumps in the booster set, between 2 and 6 pumps. The number following the pump type designation (e.g.: 32, 45 and 64) indicates the flow rate of the pump in m³/h. Full code example: Hydro MPC-E 2 CRE32-2-U2D-A-A-GHJ Where: Hydro MPC = Product name. -E = System type; All pumps with E-motor or CUE, and can also be -F for Fixed-speed pumps, 1 CUE or -S for Fixed-speed pumps. 2 = Number of pumps, this can be any number between 2 and 6. CRE = Pump type, can also be pumps beginning CR, CRI or CRIE. 3, 5, 10, 15, 20, 32, 45, 64 = flow rate of the pump in m³/h. U2 = Voltage, can also be U1, U3, U4, U5, U6, U7, U8, U9, UA, UB, UC, UD or UX. D = Design, can also be A, B, C, E, F, G, H, I or W. -A = Starting method; E (speed control). -A = Material combination; Stainless steel manifold, base frame and standard valves. -HJ = Options;, H - Dry-running protection, J - Redundant sensor.

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#240802003

Range of shower handsets and overhead showers with (plastic or chrome plated plastic bodies). Open Outlet use only Maximum operating temperature 75.0°C

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
240802003
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Note:
Open outlet use only.
Size:
½” BSP (M) - All other models ½” Captive nut - G50013-2C06, G07011-2C14 and G06011-2C24
Marking:
XIHE on front of body or captive nut
Installation Requirements:
R001 R040
Expiry date:
31/08/2029
Model:
S13034-2C02 S16073-2C03 S99023-2C02 S101015-2C02 S10023-2C02 S10035-2C02 S16023-2C04 S17023-2C02 S04244-2C02 G06011-2C24 G07011-2C14 G50013-2C06 S33011-2C11 S81011-2C02 S10011-2C02 S13041-2C01 S16031-1F02 Model added November 2024 S16061-2C03

Approval Holder:
Fujian Xihe Sanitary Ware Technology Co., Ltd.
Company Name
Fujian Xihe Sanitary Ware Technology Co., Ltd.
Address
High-Tech Industrial Zone, Luncang Town, Nan'An City, Fujian 362304
Country
China
Phone
+86 0595-86186107

View All Listings by this Company
Manufacturer:
Fujian Xihe Sanitary Ware Technology Co., Ltd.
Company Name
Fujian Xihe Sanitary Ware Technology Co., Ltd.
Address
High-Tech Industrial Zone, Luncang Town, Nan'An City, Fujian 362304
Country
China
Phone
+86 0595-86186107

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1730 of 2245

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.