Directory Search Results

Print List

#2204720

Range of lock shield or handwheel operated gate valves with brass bodies, gate & PTFE seals, for use with copper tube manufactured to EN1057. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
2290 Valves
Section Subtitle:
Stop, gate, metal.
WRAS Approval Number:
2204720
Size:
see model
Marking:
MF & size on body.
Installation Requirements:
R001
Expiry date:
30/04/2027
Model:
Gate valve light pattern C x C models: M33150000 & M33150000LP – 15MM M33220000 & M33220000LP– 22MM M33280000 & M33280000LP– 28MM Lock shield Gate valve light pattern C x C models: M33150000LPLK – 15MM M33220000LPLK – 22MM M33280000LPLK – 28MM

Approval Holder:
Masterflow Products Limited
Company Name
Masterflow Products Limited
Address
Globall House 95 Vantage Point West Mindlands
Postcode
DY6 7FT
Country
United Kingdom

View All Listings by this Company

Print This Approval


#2010427

Range of gate valves incorporating bronze bodies and wedges with PTFE seals. The valves are operated via a non-rising spindle with a hand wheel operating member. Maximum working pressure 20.0 bar. Maximum operating temperature 85°C.

Section:
2290 Valves
Section Subtitle:
Stop, gate, metal.
WRAS Approval Number:
2010427
Size:
½” BSP (F) - 2” BSP (F).
Marking:
BV, size and PN20 on body. Belven, PN20, WRAS and other technical information on operating member.
Installation Requirements:
R001
Expiry date:
31/10/2025
Model:
BV201W SERIES

Approval Holder:
Belven NV
Company Name
Belven NV
Address
Blokhuisstraat 24, Industriepark Noord 1, B-2800 Mechelen
Country
Belgium

View All Listings by this Company

Print This Approval


#240102719

Stuart CM range of in-line water conditioners with stainless steel bodies and catalytic alloy core. Maximum working pressure 16.0 bar. Maximum operating temperature 100°C.

Section:
2410 Water conditioners, de-scalers, phosphate dosing, magnetic, electrolytic and electronic
Size:
Please refer to model.
Marking:
Stuart Water Conditioner, flow arrow and serial number on adhesive label on body.
Installation Requirements:
R001 R120 R170
Expiry date:
31/01/2029
Model:
Stuart Water Conditioner CM23-45 - ½” BSP (M). Stuart Water Conditioner CM46-75 - ¾” BSP (M). Stuart Water Conditioner CM76-115 - 1” BSP (M). Stuart Water Conditioner CM116-170 - 1¼” BSP (M). Stuart Water Conditioner CM171-265 - 1½” BSP (M). Stuart Water Conditioner CM266-360 - 2” BSP (M). Stuart Water Conditioner CM361-685 - 2½” Flanged. Stuart Water Conditioner CM686-1260- 3” Flanged.

Approval Holder:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley-on-Thames Oxfordshire
Postcode
RG9 2AD
Country
United Kingdom
Phone
01491 572655
General Email
stuart.savill@stuart-turner.co.uk

View All Listings by this Company

Print This Approval


#2211064

Range of magnetic, electrolytic or combined magnetic & electrolytic scale inhibitors with nickel plated copper bodies, for use with copper pipe manufactured to BS EN 1057. Maximum working pressure 12.0 bar. Cold water use only.

Section:
2410 Water conditioners, de-scalers, phosphate dosing, magnetic, electrolytic and electronic
Size:
15mm or 22mm compression.
Marking:
Product name Wyndam on adhesive label.
Installation Requirements:
R001 R120 R170
Expiry date:
30/11/2027
Model:
WYNDAM 15 MAGNETIC, WYNDAM 22 MAGNETIC, WYNDAM 15 ELECTROLYTIC & WYNDAM 22 ELECTROLYTIC WATER CONDITIONERS,

Approval Holder:
FORTIS MERCHANTS LTD
Company Name
FORTIS MERCHANTS LTD
Address
SUSSEX HOUSE QUARRY LANE
Postcode
PO19 8PE

View All Listings by this Company

Print This Approval


#240502712

Range of UV disinfection units with stainless steel bodies. Maximum working pressure 10.3 bar. Maximum operating temperature 60°C.

Section:
2411 Disinfection Equipment
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Please refer to model.
Marking:
Luminor Rainier, model, WRAS and serial number on adhesive label on body
Installation Requirements:
R001 R150 R170
Expiry date:
31/05/2029
Model:
Single Lamp UV Disinfection Units: LRx-35X Rainier - 1½” NPT (M). LRx-55X Rainier - 2” NPT (M). LRx-85X Rainier - 2” NPT (M). Double Lamp UV Disinfection Units: LRx-110X Rainier - 2½” NPT (M). LRx-140X Rainier - 3” NPT (M). LRx-175X Rainier - 4” NPT (M). X denotes a UV sensor or a glow plug and is replaced with: 5= Glow Plug & 6 = UV Sensor. X denotes the type of power cord and is replaced with: 1 = NEMA 5/15. 2 = CEE 7/7. 3 = BS1363. 4 = AS/NZ 3112. 5 = NEMA 6/15. Additional Suffixes can be used for different lamps or sensor calibrations: HW, TOC or 50.
Product Images

Approval Holder:
Luminor Environmental Inc.
Company Name
Luminor Environmental Inc.
Address
80 Southgate Drive, Unit 4, Guelph, ON Guelph
Postcode
N1G 4P5
Country
Canada,

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1679 of 2230

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.