Directory Search Results

Print List

#2402702

Range of deck mounted flow control valves (brass bodies - various finishes) incorporating a quarter turn ceramic disc headwork with either a single lever (V7K42-L models) or cross top (V7K42-X models) operating member. Maximum working pressure 5.0 Bar.

Non-metallic materials and components comply with BS6920 at 60°C

Section:
2170 Valves
Section Subtitle:
Flow control, manually operated.
WRAS Approval Number:
2402702
Size:
¾” BSP M
Marking:
SHS on underside of operating member.
Installation Requirements:
R001
Expiry date:
28/02/2029
Model:
V7K42-LF-XX V7K42-XF-XX V7K42-LK-XX V7K42-XK-XX V7K42-LW-XX V7K42-LL-XX Where the product code suffix ‘XX’ denotes the surface finish. It will always be 2 or 3 digits, which can be any combination of numbers and/or letters. As examples: CP = chrome finish, URM = urban brass matt lacquered.

Approval Holder:
Samuel Heath & Sons Plc
Company Name
Samuel Heath & Sons Plc
Address
100 Leopold Street Birmingham
Postcode
B12 0UJ
Country
United Kingdom
Phone
+44 (0) 1217 662 200
General Email
kay.stead@samuel-heath.com

View All Listings by this Company

Print This Approval


#2310397

Range of spring loaded, non-return valves with ductile iron bodies (blue epoxy powder coated) with stainless steel discs, springs and shafts and EPDM seat. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.

Non-metallic materials and components comply with BS6920 at 85°C

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
2310397
Size:
Flanged connection - DN50, DN65, DN80, DN100, DN125, DN150, DN200, DN250, DN300.
Marking:
Belven, model number, DN, PN, WRAS, seat on data plate, Flow arrow, size casted on body.
Installation Requirements:
R001
Expiry date:
31/10/2028
Model:
BV224W series non return valves.

Approval Holder:
Belven NV
Company Name
Belven NV
Address
Blokhuisstraat 24, Industriepark Noord 1, B-2800 Mechelen
Country
Belgium

View All Listings by this Company

Print This Approval


#2310395

Range of spring loaded, non-return valves with ductile iron bodies (blue epoxy powder coated) with stainless steel discs, springs and shafts and EPDM seat. Maximum working pressure 25.0 bar. Maximum operating temperature 85°C.

Non-metallic materials and components comply with BS6920 at 85°C

Section:
2185 Valves
Section Subtitle:
Non-return, spring loaded, resilient trim. Devices listed under this heading do not provide sufficient protection against backflow to meet the requirements of The Water Supply (Water Fittings) Regulations 1999 (England and Wales), The Water Supply (Water Fittings) (Scotland) Byelaws 2014 or The Water Supply (Water Fittings) Regulations (Northern Ireland) 2009. For this purpose reference should not be made to `Backflow Prevention Devices`.
WRAS Approval Number:
2310395
Size:
Flanged connection - DN50, DN65, DN80, DN100, DN125, DN150, DN200, DN250, DN300.
Marking:
Flow IT by Flowcon ME, model number, DN, PN & WRAS on metal data plate, Flow arrow, size casted on body.
Installation Requirements:
R001
Expiry date:
31/10/2028
Model:
FTDDCW series non return valves.

Approval Holder:
flowconME s.r.l.
Company Name
flowconME s.r.l.
Address
via Cesare Battisti, 2 CAP 40123 Bologna
Country
Italy
Phone
+39.051.9912714

View All Listings by this Company

Print This Approval


#2312311

Pressure relief valves with a brass body incorporating EPDM ‘O’ rings for 35890040 and EPDM diaphragm for 35900040, pre-set at 3.0 bar. Model 35890040 incorporates a manually operated lever type lifting gear Maximum working pressure 10 bar. Maximum operating temperature 90°C.

Section:
2210 Valves
Section Subtitle:
Pressure relief.
WRAS Approval Number:
2312311
Note:
Primary circuit use only
Size:
SEE MODEL
Marking:
RBM logo, CE, flow arrow and size on body. Date of manufacture WWYY on 3590040. 3.0 bar on lever of 35890040.
Installation Requirements:
R001 R200
Expiry date:
31/12/2028
Model:
35900040: 21mm (F) boiler connection 35890040: 21.90mm (M) boiler connection

Approval Holder:
R.B.M. S.p.A.
Company Name
R.B.M. S.p.A.
Address
Via Industriale no 25, 25060 S. San Giovanni di Polaveno (BS), Brescia
Country
Italy
Phone
+39 030 253 7211
General Email
info@rbm.eu

View All Listings by this Company
Manufacturer:
R.B.M. S.p.A.
Company Name
R.B.M. S.p.A.
Address
Via Industriale no 25, 25060 S. San Giovanni di Polaveno (BS), Brescia
Country
Italy
Phone
+39 030 253 7211
General Email
info@rbm.eu

View All Listings by this Company

Print This Approval


#2311091

Range of pressure relief valves with gunmetal bodies, EPDM diaphragms and lever operated easing gear. The relief setting is between 0.5 - 16.0 bar depending on the model. Maximum operating temperature 99°C

Section:
2210 Valves
Section Subtitle:
Pressure relief.
WRAS Approval Number:
2311091
Size:
642 DN15 - ½” BSP (F) inlet x ½” BSP (F) outlet, DN20 - ¾” BSP (F) inlet x ¾” BSP (F) outlet, DN25 - 1” BSP (F) inlet x 1” BSP (F) outlet, DN32 - 1 ¼” BSP (F) inlet x 1 ¼” BSP (F) outlet, DN40 - 1 ½” BSP (F) inlet x 1 ½” BSP (F) outlet DN50 - 2” BSP (F) inlet x 2” BSP (F) outlet DN65 - 2 ½” BSP (F) x 2 ½” BSP (F) outlet, DN25 - DN25 flanged inlet x 1” BSP (F) outlet, DN32 - DN32 flanged inlet x 1 ¼” BSP (F) outlet, DN40– DN40 flanged inlet x 1 ½” BSP (F) outlet, DN50 - DN50 flanged inlet x 2” BSP (F) outlet DN65 - DN65 flanged inlet x 2½” BSP (F) outlet 6420 DN15 - ½” BSP (F) inlet x ½” BSP (F) outlet, DN20 – ¾” BSP (F) inlet x ¾” BSP (F) outlet, DN25 – 1” BSP (F) inlet x 1” BSP (F) outlet, DN32 - 1¼” BSP (F) inlet x 1¼” BSP (F) outlet, DN40 - 1½” BSP (F) inlet x 1½” BSP (F) outlet, DN50 – 2” BSP (F) inlet x 2” BSP (F) outlet, DN65 - 2½” BSP (F) inlet x 2½” BSP (F) outlet, DN15 - ½” BSP (M) inlet x ½” BSP (F) outlet, DN20 – ¾” BSP (M) inlet x ¾” BSP (F) outlet, DN25 – 1” BSP (M) inlet x 1” BSP (F) outlet, DN32 - 1¼” BSP (M) inlet x 1¼” BSP (F) outlet, DN40 - 1½” BSP (M) inlet x 1½” BSP (F) outlet, DN50 – 2” BSP (M) inlet x 2” BSP (F) outlet DN65 - 2½” BSP (M) inlet x 2½” BSP (F) outlet
Marking:
Albion logo, size, pressure, flow arrow, mode, material and other technical information on body.
Installation Requirements:
R001 R120
Expiry date:
30/11/2028
Model:
642 6420 Models added December 2023: 645: DN15 - ½” BSP (F) inlet x ¾” BSP (F) outlet, DN20 - ¾” BSP (F) inlet x 1” BSP (F) outlet, DN25 - 1” BSP (F) inlet x 1 ¼” BSP (F) outlet, DN32 - 1 ¼” BSP (F) inlet x 1 ½” BSP (F) outlet, DN40 - 1½” BSP (F) inlet x 2” BSP (F) outlet, DN50 - 2” BSP (F) inlet x 2½” BSP (F) outlet, DN25 - DN25 flanged inlet x 1¼” BSP (F) outlet, DN32 - DN32 flanged inlet x 1½” BSP (F) outlet, DN40 - DN40 flanged inlet x 2” BSP (F) outlet, DN50 - DN50 flanged inlet x 2½” BSP (F) outlet. 6450: DN15 - ½” BSP (F) inlet x ¾” BSP (F) outlet, DN20 - ¾” BSP inlet (F) x 1” BSP (F) outlet, DN25 - 1” BSP (F) inlet x 1¼” BSP (F) outlet, DN32 - 1¼” BSP (F) inlet x 1½” BSP (F) outlet, DN40 - 1½” BSP (F) inlet x 2” BSP (F) outlet, DN50 - 2” BSP (F) x 2 ½” BSP (F) outlet, DN15 - ½” BSP (M) inlet x ¾” BSP (F) outlet, DN20 - ¾” BSP inlet (M) x 1” BSP (F) outlet, DN25 - 1” BSP (M) inlet x 1¼” BSP (F) outlet, DN32 - 1¼” BSP (M) inlet x 1½” BSP (F) outlet, DN40 - 1½” BSP (M) inlet x 2” BSP (F) outlet.

Approval Holder:
Albion Valves (UK) Limited
Company Name
Albion Valves (UK) Limited
Address
9a Fallbank Industrial Estate Dodworth Barnsley
Postcode
S75 3LS
Country
United Kingdom
Phone
01226 729900
General Email
samjed@albionvalvesuk.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1290 of 2321

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.