Directory Search Results

Print List

#2306328

Range of brass bodied compression fittings for use with copper pipe(manufactured to EN1057). . Maximum working pressure 16.0 bar @ 30°C, 10.0 bar @ 65°C and 6.0 bar @ 100°C.

Section:
1140 Fittings for use with Tube and Pipe
Section Subtitle:
Compression, metal, for use with copper tube. Unless specified in the individual approval, the products within this section are not suitable for below ground use
WRAS Approval Number:
2306328
Size:
see model
Marking:
Kembla, size, EN1254-2 on nut.
Installation Requirements:
R001
Expiry date:
30/06/2028
Model:
301 – Straight Coupling: 15mm Code 301015, 22mm Code 301022. 301RED – Reducing Coupling: 22x15mm Code 30102215. 302 – Male Straight Adaptor: 15mm x 1/2" Code 30201515, 22mm x 1/2" Code 30202215, 22mm x 3/4" Code 30202222. 303 – Female Straight Adaptor: 15mm x 1/2" Code 30301515, 22mm x 1/2" Code 30302215, 22mm x 3/4" Code 30302222. 401 – 90° Elbow: 15mm Code 401015, 22mm Code 401022. 401RED – Reducing Elbow: 22x15mm Code 40102215. 401(45) – 45° Elbow: 15mm Code 40145015, 22mm Code 40145022. 402 – Male Elbow: 15mm x 1/2" Code 40201515, 22mm x 3/4" Code 40202222. 403 – Female Elbow: 15mm x 1/2" Code 40301515, 22mm x 1/2" Code 40302215, 22mm x 3/4" Code 40302222. 601EQ – Equal Tee: 15mm Code 601015, 22mm Code 601022. 601REE – Reduced Both End Tee: 15x15x22mm Code 6010151522. 601REB – Reduced End and Branch Tee: 22x15x15mm Code 6010221515. 601RE – Reduced End Tee: 22x15x22mm Code 6010221522. 601RB – Reduced Branch Tee: 22x22x15mm Code 6010222215. 617 – Female Branch Tee: 15mm x 15mm x 1/2" Code 6170151515, 22mm x 22mm x 1/2" Code 6170222215, 22mm x 22mm x 3/4" Code 6170222222. 453 – Female Wallplate Elbow: 15mm x 1/2" Code 45301515, 22mm x 3/4" Code 45302222. 068 – Reducing Set: 22x15mm Code 06802215. 305 – Stop End: 15mm Code 305015, 22mm Code 305022.
Product Images

Approval Holder:
Kembla (HK) Limited
Company Name
Kembla (HK) Limited
Country
China
Phone
+852 2833 9308
General Email
charles.tam@kembla.com.hk

View All Listings by this Company

Print This Approval


#2306310

Range of ultrasonic water meters with plastic bodies. The inlet incorporates a plastic strainer. Maximum working pressure 16.0 bar.

Non-metallic materials and components comply with BS6920 at 50°C

Section:
1505 Water Meters
Size:
MFW-DN15: ¾” BSP (M), MFW-DN20: 1” BSP (M).
Marking:
Company logo MEMF, manufacturer, manufacturer address, barcode and product information printed on base plate. DN and flow arrow moulded on body.
Installation Requirements:
R001 R008
Expiry date:
30/06/2028
Model:
MFW-DN15 (½” internal bore), MFW-DN20 (¾” internal bore).
Product Images

Approval Holder:
MEMF Electrical Industries Co.
Company Name
MEMF Electrical Industries Co.
Address
Second Industrial Area, Street#179, PO. Box 355989 Riyadh 11383, Saudi Arabia

View All Listings by this Company
Manufacturer:
MEMF Electrical Industries Co.
Company Name
MEMF Electrical Industries Co.
Address
Second Industrial Area, Street#179, PO. Box 355989 Riyadh 11383, Saudi Arabia

View All Listings by this Company

Print This Approval


#2307802

‘DM900’ range of flow measuring devices with stainless steel bodies. Maximum working pressure 25.0 bar. Maximum operating temperature 99°C.

Section:
1520 Meter Chambers
Section Subtitle:
In-wall.
WRAS Approval Number:
2307802
Size:
DN65, DN80, DN100, DN125 and DN150 wafer flange inlet and outlet.
Marking:
Crane, size & pressure on adhesive label on body.
Installation Requirements:
R001
Expiry date:
31/07/2028
Model:
Crane DM900 - Flow Measurement Device (FMD)

Approval Holder:
Crane Ltd
Company Name
Crane Ltd
Address
Crane House, Epsilon Terrace, West Road, Ipswich
Postcode
IP3 9FJ
Country
United Kingdom
Phone
01473 277 364
General Email
enquiries@cranefs.com

View All Listings by this Company

Print This Approval


#2305911

Range of pressure, flow and temperature sensors. The VFI sensors have stainless steel bodies, all other models have plastic bodied sensors. The MFS and VFS models are supplied with a plastic (composite) or stainless-steel flow pipe. The VFI models are supplied with a stainless-steel flow pipe. The products can also be supplied with a range of fittings/end connections (see model and size). Maximum working pressures: ITS, LPS, RPS, MFS (composite flow pipe) and VFS (composite flow pipe) models: 24.0 bar. CPS models (added February 2024): 24.0 bar. DPS: Models with vent hole: 16.0 bar. All other models: 24.0 bar. MFS (stainless steel flow pipe) and MFS (stainless steel flow pipe): 30.0 bar. VFI non-flanged models: 30.0 bar. VFI flanged models: 30.0 bar or as per flange PN rating 16.0 bar or 25.0 bar (whichever is lower). Maximum operating temperature 99°C.

Section:
1530 Miscellaneous Fittings
Size:
CPS/ITS/LPS/RPS: BRASS CW 617N: ¼" BSPP (M). S/S EN 14408: ½" BSPP (M) w/vent port. ½" BSPT (M). ½" BSPT (M) (short). ½" NPT (M). Plastic: ⅜" BSPP (M). DPS: BRASS CW 617N: ½" BSPT (M) w/vent hole. 15.5mm w/vent hole. S/S EN 1.4401: ½" BSPT (M) w/vent hole. ½" BSPP (M). Housing only S/S (EN 1.4408): 2x ⅛" NPT (F). End connections for housing only: AISI 316 6mm compression, 6mm and 8mm tube. MFS, VFS (COMPOSITE FLOWPIPE): FLOWPIPE ONLY: 1”, 1¼”, 1½” BSPP (M). END CONECTIONS: BRASS CW 617N: ½", ¾" BSPP (M). ¾", 1", 1¼" BSPT (M). ½", ¾", 1", 22mm, 28mm SWEAT. S/S EN 1.4401: ¾", 1", 1¼" NPT (M). 1", 1¼" BSPT (M). MFS, VFS (S/STEEL FLOWPIPE): FLOWPIPE ONLY (EN 1.4408): ¾", 1", 1¼" BSPP (M). ¾", 1", 1¼" NPSM (M). 1" FLANGE. END CONNECTIONS: BRASS CW 617N: ½", ¾", 1" BSPT (M). ¾", 1", 22mm & 28mm SWEAT. S/S EN 1.4401: ¾", 1" BSPT (M). ¾", 1" NPT (M). VFI: CAST IRON OR S/STEEL EN 1.4408 FLANGED: DN18/25/32 (1¼"). DN40/50 (2"). DN65/80/100. S/S EN 1.4401: 1”, 1¼" BSPT (M). 1, 1¼" NPT (M).
Marking:
VFI models: Grundfos and model type (VFI) on adhesive label on sensor. Grundfos on flow pipe. All other models: Grundfos on top of sensor housing. Model type (ITS/LPS/RPS/MFS/VFS) on adhesive label on sensor.
Installation Requirements:
R001
Expiry date:
31/05/2028
Model:
Model: CPS, ITS, LPS or RPS sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF CPS, ITS, LPS or RPS with or without accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII CPS model added February 2024. Fortron body material added June 2024. Product: [A] Must be CPS, ITS, LPS or RPS Range and unit: [B] Of no importance for drinking water* Gen.: [C] Of no importance for drinking water* Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be E or I, second and third character have no importance for drinking water* Materials: [G] Must be either -B, -S, -I, -D or -- Connection: [H] Must be either 03A, 03B, 03N, 02P, 01K, 16P, 66P or --- Packaging: [I] Of no importance for drinking water* ------ DPS sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF DPS with or without accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII EPDM O-rings and EPDM anti-sedimentation sealing cap added June 2024 Product: [A] Must be DPS Range and unit: [B] Of no importance for drinking water* Gen.: [C] All characters allowed except 4 and 5 Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be E or I, the second must not be A. The third character has no importance for drinking water* character have no importance for drinking water* Materials: [G] Must be either -B, -S, S-, SS or -- Connection: [H] Must be either 06C, 06T, 08T, 01L, 24N, 63B, 64S or --- Packaging: [I] Of no importance for drinking water* ------ MFS or VFS sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF MFS or VFS with or without composite flow pipe accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII Product: [A] Must be MFS or VFS Range and unit: [B] Of no importance for drinking water* Gen.: [C] Of no importance for drinking water* Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be A or E, second and third character have no importance for drinking water* Materials: [G] Must be either C-, CB, CS or -- Connection: [H] Must be either 03P, 03S, 04B, 04N, 04P, 04S, 05B, 05N, 05P, 05S, 07B, 07N, 07P, 09P, 01K, 15K, 18K, 22S, 26R, 28S or --- Note: 04N, 05N and 07N only in combination with CS [G] Packaging: [I] Of no importance for drinking water* ------ MFS or VFS sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF MFS or VFS with or without stainless steel flow pipe accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII Product: [A] Must be MFS or VFS Range and unit: [B] Of no importance for drinking water* Gen.: [C] Of no importance for drinking water* Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be A or E, second and third character have no importance for drinking water* Materials: [G] Must be either QB, QS, Q- or -- Connection: [H] Must be either 03B, 04B, 04M, 04N, 04P, 04S, 05B, 05M, 05N, 05P, 05S, 07M, 07P, 01K, 01L, 102, 22S, 28S, 51G or --- Packaging: [I] Of no importance for drinking water* ------ VFI sensor alone (only for internal sale): Sensor/ AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF VFI with or without accessories (saleable): AAA/ B.B-BBB B/ C/ D/ E E.EE EE/ FFF/ GG/ HHH/ IIII Product: [A] Must be VFI Range and unit: [B] Of no importance for drinking water* Gen.: [C] Of no importance for drinking water* Output: [D] Of no importance for drinking water* Cable: [E] Of no importance for drinking water* Sealing: [F] The first character must be E, second and third character have no importance for drinking water* Materials: [G] Must be either S-, SG, SS or -- Connection: [H] Must be either --F, --P, 05B, 05N, 07B, 07N, 07P, 09P, 30F, 31F, 32F, 33F, 35F, 37F or 42F Packaging: [I] Of no importance for drinking water* ------ Where: Code for sealing [F]: 1st character: “A” means EPDM O-rings and EPDM sealing sleeve. “E” means EPDM O-rings. “I” means EPDM O-rings and EPDM anti-sedimentation sealing cap Code for material [G]: 1st character: “C” means composite flow pipe. “Q” means flow insert and (except service sets) also a stainless steel flow pipe. “S” means stainless steel adapter (for DPS) or flow pipe. “-“ means no adapter (for DPS) or flow pipe. 2nd character: "B" means brass (fitting). “D” means Fortron (fitting) “G” means cast iron (flange). “I” means composite (fitting). "S" - means stainless steel (fitting or flange). “-“ means no further accessories included. Code for connection (H): 1st two characters: “01” means 10 mm. “02” means ¼”. “03” means ½”. “04” means ¾”. “05” means 1”. “06” means 6 mm. “07” means 1¼”. “08” means 8 mm. “09” means 1½”. (Internal note - this is on a flow pipe connection) “15” means 15 mm. “16” means ⅜”. “18” means 18 mm. “22” means 22 mm. “24” means ⅛”. “26” means 42 mm. “28” means 28 mm. “30” means DIN PN25/40 DN18/25/32, ANSI B16.5 Class 300 - 1¼". “31” means DIN PN16/25/40 DN40, ANSI B16.5 Class 300 - 2". “32” means DIN PN16/25/40 DN50, ANSI B16.5 Class 300 - 2". “33” means ISO/DIN PN25/40 DN65. “35” means ISO/DIN PN25/40 DN80. “37” means ISO/DIN PN16 DN100. “42” means ISO/DIN PN25/40 DN100. “51” means 1" / ¾". “63” means ½" and ventilation opening. “64” means 15.5 mm and ventilation opening. “66” means ½” and M8 ventilation port “--” means no accessories included and thus implicitly the dimension of the sensor connection, which for DPS, ITS, LPS, MFS, RPS and VFS is 10 mm (of no importance for drinking water). For VFI this is used for service sets, which includes the sensor and the bluff body, but not the flow pipe (of no importance for drinking water). 3rd character: “A” means BSPT (short). “B” means BSPT. “C” means Compression. “F” means flange. “K” means standard clip included (of no importance for drinking water). “L” means special clip included (of no importance for drinking water). “M” means NPSM. “N” means NPT. “P” means BSPP. “R” means union not (union nut included but no fittings included). “S” means sweat. “T” means hose connector. “2” means both standard clip and special clip included (of no importance for drinking water). “-“means no accessories included and thus implicitly the connection type of the sensor, which for DPS, ITS, LPS, MFS, RPS and VFS is a clip (of no importance for drinking water). Further details on the nomenclature: * All characters are allowed NOTE - For customer-specific numbers, GG/HHH/IIII in the saleable code is replaced by the customer name. However, the customer-specific products are still covered if they meet the requirements specified in the standard sales code.

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#2306305

Range of temperature measurement devices with bronze bodies and EPDM o-rings. Maximum operating pressure 10.0 bar.

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1530 Miscellaneous Fittings
Size:
see model;
Marking:
Kemper logo, size and flow arrow on body
Installation Requirements:
R001
Expiry date:
30/06/2028
Model:
6280G0XX00. XX stands for 15, 20, 25, 32, 40 or 50 related to the dimension of the sensor (mm).
Product Images

Approval Holder:
Gebr. Kemper GmbH + Co. KG
Company Name
Gebr. Kemper GmbH + Co. KG
Address
Harkortstr. 5 57462 Olpe Germany
Phone
+49(0) 27618910
General Email
info@kemper-olpe.de

View All Listings by this Company
Manufacturer:
Gebr. Kemper GmbH + Co. KG
Company Name
Gebr. Kemper GmbH + Co. KG
Address
Harkortstr. 5 57462 Olpe Germany
Phone
+49(0) 27618910
General Email
info@kemper-olpe.de

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1147 of 2240

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.