#2305332

Range of wall unions with chrome plated brass bodies. Maximum operating temperature 60°C Open outlet use only

Non-metallic materials and components comply with BS6920 at 60°C

Section:
1530 Miscellaneous Fittings
Size:
½” BSP(M)
Marking:
Grohe on body
Installation Requirements:
R001 R040
Expiry date:
31/05/2028
Model:
28626000 28636000 28628000 28671000
Product Images

Approval Holder:
Grohe AG
Company Name
Grohe AG
Address
Industriepark Edelburg Hemer
Postcode
58675
Country
Germany
Phone
02372 930
General Email
marc.engelhardt@lixil.com

View All Listings by this Company
Manufacturer:
Grohe AG
Company Name
Grohe AG
Address
Industriepark Edelburg Hemer
Postcode
58675
Country
Germany
Phone
02372 930
General Email
marc.engelhardt@lixil.com

View All Listings by this Company

Print This Approval


#2305912

Range of level and flow transmitters with plastic bodies. Maximum working pressure 3.0Bar

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1530 Miscellaneous Fittings
Size:
1 ½” BSP (M) 1 ½” NPT (M)
Marking:
EMERSON Rosemount logo, model number and other technical information on body.
Installation Requirements:
R001
Expiry date:
31/05/2028
Model:
Rosemount 1208A Rosemount 1208C

Approval Holder:
Rosemount Tank Radar AB
Company Name
Rosemount Tank Radar AB
Address
Layoutvägen 1, 43533 Mölnlycke Sweden

View All Listings by this Company

Print This Approval


#2305913

Flow regulator with a plastic body. 4.0 - 8.5L/min. Claims of flow regulation performance made by manufacturer have note been tested and are not covered as part of this approval.

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1530 Miscellaneous Fittings
WRAS Approval Number:
2305913
Note:
Open outlet use only.
Size:
Ø20.37 x 19.33mm
Marking:
HL2024 FC (brand of HaGePe) on body
Installation Requirements:
R001
Expiry date:
31/05/2028
Model:
HL2024

Approval Holder:
HaGePe International B.V (HGP International)
Company Name
HaGePe International B.V (HGP International)
Address
Huizermaatweg 27-2 1273 NA Huizen
Country
Netherlands

View All Listings by this Company

Print This Approval


#2305069

Concealed wall mounted rough inset with a brass body, incorporating EDPM O-rings. Maximum working pressure 5.0 Bar

Non-metallic materials and components comply with BS6920 at 85°C

Section:
1535 Miscellaneous
Section Subtitle:
Tap accessories.
WRAS Approval Number:
2305069
Size:
½” BSP F Inlets
Marking:
SHS logo on body
Installation Requirements:
R001 R010 R040
Expiry date:
31/05/2028
Model:
T2020-IS-XX Where the product code suffix ‘XX’ denotes the product is unfinished
Product Images

Approval Holder:
Samuel Heath & Sons Plc
Company Name
Samuel Heath & Sons Plc
Address
100 Leopold Street Birmingham
Postcode
B12 0UJ
Country
United Kingdom
Phone
+44 (0) 1217 662 200
General Email
kay.stead@samuel-heath.com

View All Listings by this Company
Manufacturer:
Samuel Heath & Sons Plc
Company Name
Samuel Heath & Sons Plc
Address
100 Leopold Street Birmingham
Postcode
B12 0UJ
Country
United Kingdom
Phone
+44 (0) 1217 662 200
General Email
kay.stead@samuel-heath.com

View All Listings by this Company

Print This Approval


#2303041

Range of multistage pumps (VL and CL series) and submersible pumps (VN, CN, ES and CS series) with stainless steel bodies and impellers and NBR gaskets and ‘O’-rings. Maximum working pressure 15.0 bar (VL and CL series pumps only).

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2303041
Note:
VN, CN, ES and CS series submersible pumps: The level control assembly (cable and level control) are not covered under the scope of this approval. These pumps are also open outlet use only.
Size:
VL and CL series: 1 ¼” Female BSP inlet x 1 ½” Female BSP outlet. VN and CN series: 1 ¼” Female BSP outlet - 2" Female BSP outlet. ES and CS series: 1 ¼” Female BSP outlet.
Marking:
Franklin electric Srl logo, WRAS, model no., serial no., pressure and date of manufacture (DD/MM/YYY) on body.
Installation Requirements:
R001 R415
Expiry date:
31/03/2028
Model:
VNx1/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D, x1CN/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D, VLx1/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D, x1CL/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D, ESx1/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D, x1CS/xx2 Ixxx3 x4x5x6 Nx7 x8Bx9x10x11Nx12 D. Where: VN, CN, VL, CL, ES, CS = Series name. VN/VL/ES series “E-TECH” brand CN/CL/CS Series “FPS” brand x1 = Nominal Flow: 3, 5, or 9. (9 is not available on ES and CS models) xx2 = number of impellers: 2 to 10 (VN/CN & VL/CL models), 2 to 8 (ES/CS models), depending on Nominal Flow and Frequency. I = Material: St/Steel 1.4301 (AISI304). xxx3 = Motor Power (kW x 10): 005, 007, 009, 011… x4 = Supply (no phase): T (three phase), M (single phase). x5 = Frequency (Hz): 5 (50 Hz), or 6 (60 Hz). x6 = Motor Configuration: L (Bi-phase, 90° single-phase), D (Three-phase, triangle), or Y (Three-phase, star). N = Mechanical seal elastomer: N = NBR. x7 = Mechanical Seal surface: 1 (Graphite / Silicon Carbide), or 2 (Silicon Carbide). x8 = Float Switch: 0 (without). B = Cable type: B (Blue). x9 = Cable size: A (4G1), B (4G1.5), C (3G1), or D (3G1.5). x10 = Cable length: O: 20m - VN/CN and ES/CS models, E: 5m - VL/CS models. x11 = Control Panel (not in contact with liquid): 0 (without), or 1 (connected - VN/CN models only). N = Nude terminal (not in contact with liquid). x12 = Option (only on VN/CN models) - Discharge head (”): Empty (1¼” Nickel plated brass), I (1¼” inox), or J (2” inox). D = Drinking water approved.
Product Images

Approval Holder:
Franklin Electric SRL
Company Name
Franklin Electric SRL
Address
Via Asolo 7 Dueville Vicenza 36031
Country
Italy
Phone
+39 0444 360366
General Email
info.it@fele.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1114 of 2240

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.