Directory Search Results

Print List

#2104001

Wall mounted outlet with detachable shower hose connector (42037UK model) and wall mounted shower outlet (42018UK model). The 42018UK model is supplied with an optional, detachable shower hose connector assembly which incorporates an integral plastic flow regulator and an approved check valve cartridge however, the complete product has not been fully tested to demonstrate it provides backflow protection. Model 42037UK has a maximum operating temperature of 80°C. Model 42018UK has a maximum operating temperature of 60°C.

Section:
1530 Miscellaneous Fittings
WRAS Approval Number:
2104001
Note:
Open outlet use only. This approval does not include a shower hose and handset.
Size:
½” BSP (M) inlet/outlet.
Marking:
42037UK: Galvincare on body. 42018UK: Galvin Engineering logo (letters ‘GE’ within an oval) on shower outlet face.
Installation Requirements:
R001 R040
Expiry date:
30/04/2026
Model:
42037UK: ‘CP Galvincare Mental Health Anti-Ligature Shower Outlet Wall Connection’. 42018UK ‘Galvincare CP-BS Mental Health Anti-Ligature Safe Connect Shower Head’.
Product Images

Approval Holder:
Galvin Engineering
Company Name
Galvin Engineering
Address
410 Victoria Road Malaga WA 6090
Country
Australia

View All Listings by this Company
Manufacturer:
Galvin Engineering
Company Name
Galvin Engineering
Address
410 Victoria Road Malaga WA 6090
Country
Australia

View All Listings by this Company

Print This Approval


#2104304

Wall bracket with a brass body (chrome plated) and EPMD ‘O’-rings. Maximum operating temperature 85°C.

Section:
1530 Miscellaneous Fittings
WRAS Approval Number:
2104304
Note:
Open outlet use only.
Size:
½” BSP (M)
Marking:
PPI on body.
Installation Requirements:
R001 R040
Expiry date:
30/04/2026
Model:
N116-S
Product Images

Approval Holder:
PPI Xiamen Industry Co., Ltd.
Company Name
PPI Xiamen Industry Co., Ltd.
Address
No 88 South Houxiang Road Xinyang Industrial Zone Haicang District Xiamen
Postcode
361022
Country
China
General Email
heatheryang@xmppi.com

View All Listings by this Company
Manufacturer:
PPI Xiamen Industry Co., Ltd.
Company Name
PPI Xiamen Industry Co., Ltd.
Address
No 88 South Houxiang Road Xinyang Industrial Zone Haicang District Xiamen
Postcode
361022
Country
China
General Email
heatheryang@xmppi.com

View All Listings by this Company

Print This Approval


#2010071

Range of booster sets with a stainless steel manifold system connecting 2 or 3 wholesome water pumps (For 2HELIX & 3HELIX models only). The set also includes spherical valves, and a non-return valve Maximum working pressure: 10.0 Bar Maximum operating temperature: 40°C

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2010071
Size:
1 ¼” BSP (F) on 1 HELIX (Centrum SV) or 2 ½” BSP (M) on 2HELIX (CENTRUM DV) and 3HELIX (CENTRUM TV).
Marking:
Wilo logo (see notes), model, PN, max temp, manufacturer and other technical info on adhesive label on pump body.
Installation Requirements:
R001 R415
Expiry date:
31/10/2025
Model:
Wilo Model Codes: Wilo CENTRUM SV406, Wilo CENTRUM SV408, Wilo CENTRUM SV605, Wilo CENTRUM SV608, Wilo CENTRUM SV1004, Wilo CENTRUM SV1006, Wilo CENTRUM DV406, Wilo CENTRUM DV408, Wilo CENTRUM DV605, Wilo CENTRUM DV608, Wilo CENTRUM DV1004, Wilo CENTRUM DV1006, Wilo CENTRUM TV406, Wilo CENTRUM TV408, Wilo CENTRUM TV605, Wilo CENTRUM TV608, Wilo CENTRUM TV1004, Wilo CENTRUM TV1006.
Product Images

Approval Holder:
Wilo UK
Company Name
Wilo UK
Address
Second Avenue Centrum 100 Burton on Trent
Postcode
DE14 2WJ
Country
Staffordshire

View All Listings by this Company
Manufacturer:
Wilo UK
Company Name
Wilo UK
Address
Second Avenue Centrum 100 Burton on Trent
Postcode
DE14 2WJ
Country
Staffordshire

View All Listings by this Company

Print This Approval


#2012926

Range of single stage centrifugal pumps with bronze housings or plastic housings (see model) and plastic impellers. Maximum working pressure 6.0 bar (UP(S)(O) 15-XX CES87 130 model only), 10.0 bar (all other models). Maximum operating temperature 95°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2012926
Note:
R008 does not apply to the bronze body models.
Size:
1” BSP (M) inlet/outlet.
Marking:
Grundfos, Grundfos logo, type, model, production no. and other technical information on data plate on top of motor. Flow arrow on body.
Installation Requirements:
R001 R008
Expiry date:
31/12/2025
Model:
Bronze pump housing: UP(S)(O) 15-XX B 130 (GFSxx). SOLAR 15-XX B 130 (GFSxx). Plastic (composite) pump housing: UP(S)(O) 15-XX CIL2 (GFSxx). SOLAR 15-XX CIL2 (GFSxx). UP(S)(O) 15-XX CES87 (GFSxx). Where: UP or SOLAR = Range name. S = Pumps equipped with electronic speed control. O = High efficiency pump. 15 = 1” BSP connections. XX = Maximum Head (dm). B = Pump housing - Bronze. CES87 or CIL2 = Pump housing - Composite. 130 (where noted) = Port length (mm).
Product Images

Approval Holder:
Grundfos Holding A/S
Company Name
Grundfos Holding A/S
Address
Poul Due Jensens Vej 7 Bjerringbro
Postcode
DK-8850
Country
Denmark
Phone
+36302482216
General Email
oszilagyi@grundfos.com

View All Listings by this Company

Print This Approval


#2011354

MBC 12-22WM & MBC 12-28WM models are wall mounted mains supply booster sets. They are supplied with two spherical isolation valves, a spherical bypass valve and two single check valve assemblies (suitable for backflow protection against Fluid Category 2). The check valve assemblies are to be installed in accordance with the manufacturers instructions, one upstream of the pump inlet and one after the bypass valve. The booster pump incorporates a plastic strainer on the inlet and a plastic flow regulator on the outlet and is housed within a wall mounted cabinet. MJ3 VM & MJ3 HM models are mains supply booster sets intended to be mounted on an expansion vessel (not supplied as part of the approval). They comprise of a pump, a suction and discharge manifold with bypass arrangement, and a spherical bypass valve which incorporates an approved check valve cartridge, however, the complete product has not been fully tested to demonstrate it provides backflow protection. The booster pump incorporates a plastic strainer on the inlet and a plastic flow regulator on the outlet. Maximum working pressure 6.0 bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2011354
Note:
All interconnecting pipework is to be supplied by the installer.
Size:
MBC 12-22WM & 12-28WM models: Quadruple layered flexible hoses consisting of a black coloured TPE inner layer, PVC middle layer, braided PE third layer and white coloured PVC outer layer with 15mm pushfit end connections. MJ3 VM & HM models: Stainless steel braided EPDM lined flexible hose assemblies with 22mm pushfit end connections.
Marking:
Stuart Turner, Stuart Turner logo, mains boost, model no., pressure, temperature and other technical information on adhesive label on pump. Stuart Turner on pump body.
Installation Requirements:
R001
Expiry date:
30/11/2025
Model:
Part code 44725: Mainboost charger MBC 12-22WM. Part code 44726: Mainboost charger MBC 12-28WM. Where: MBC = Range name: Mainsboost Charger. 12 = maximum pumped flow in l/min. 22 or 28 = 22mm or 28mm sizes bypass fittings supplied. WM = wall mounted. Part code 41712: Mainboost charger MJ3 VM. Part code 41729: Mainboost charger MJ3 HM. Where: MJ = MJ pump, version 3. VM = vertical vessel mounted. HM = horizontal vessel mounted.
Product Images

Approval Holder:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley-on-Thames Oxfordshire
Postcode
RG9 2AD
Country
United Kingdom
Phone
01491 572655
General Email
stuart.savill@stuart-turner.co.uk

View All Listings by this Company
Manufacturer:
Stuart Turner Ltd
Company Name
Stuart Turner Ltd
Address
47 Market Place Henley-on-Thames Oxfordshire
Postcode
RG9 2AD
Country
United Kingdom
Phone
01491 572655
General Email
stuart.savill@stuart-turner.co.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 111 of 1707

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.