VEGA Grieshaber KG Approvals


#240402065

Range of submersible pressure sensors and hydrostatic transmitters (supplied in lengths up to 1000m). Cold water use only.

Section:
1530 Miscellaneous Fittings
Size:
Ø22mm or 32mm (see model).
Marking:
VEGA, VEGAWELL 52, model number and other product information on label connected to cable.
Installation Requirements:
R001
Expiry date:
30/04/2029
Model:
VEGAWELL 52 WL52.XX α A β γ I δ ε ζ X Where: XX :- Approval Blank/without (not applicable to model seeking WRAS approval). α :- Fastening / Material X4 :- Without GE :- Adjustable screw connection for suspension cable G¾ PN3, ISO228-1 / 316L. GC :- Adjustable screw connection for suspension cable G1 PN3, ISO228-1 / 316L. GD :- Adjustable screw connection for suspension cable 1NPT PN3, ASME B1.20.1 / 316L. GA :- Adjustable screw connection for suspension cable G1½ PN3, ISO228-1 / 316L. GB :- Adjustable screw connection for suspension cable 1½NPT PN3, ASME B1.20.1 / 316L. Version / Process temperature A :- Suspension cable PE / -20...+60°C β :- Length of suspension cable K :- 6m PE suspension cable. L :- 12m PE suspension cable. M :- 27m PE suspension cable. T :- Individually selected length PE suspension cable. γ :- Transmitter material / Diameter V :- 316l / 22mm. D :- Duplex (1.4462) / 32mm. Sealing concept / Wetted seal I :- Double / EPDM (A+P 70.10-02), EPDM (70.503-00) δ :- Measuring rate A :- rel. / 0 … +0.1 bar (0 … + 10kPa). B :- rel. / 0 … +0.2 bar (0 … + 20kPa). C :- rel. / 0 … +0.4 bar (0 … + 40kPa). D :- rel. / 0 … +1.0 bar (0 … + 100kPa). E :- rel. / 0 … +2.5 bar (0 … + 250kPa). F :- rel. / 0 … +5.0 bar (0 … + 500kPa). G :- rel. / 0 … +10 bar (0 … + 1,000kPa). H :- rel. / 0 … +25 bar (0 … + 2,500kPa). ε :- Electronics C :- Two-wire 4…20mA. D :- Two-wire 4…20mA/HART + Four-wire PT100. ζ :- Accuracy class 1 :- 0.2%, 2 :- 0.1%. Transmitter option X :- without.

Approval Holder:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
General Email
info.de@vega.com

View All Listings by this Company

Print This Approval


#240902039

Range of VEGAPULS radar sensors for level measurement with plastic bodies. Cold water use only. Open outlet use only.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
See model key
Marking:
VEGA logo date of manufacturer (YYYY), serial number and other technical data on body
Installation Requirements:
R001
Expiry date:
30/09/2029
Model:
PSC21.ab-c-d-N-f-g-h-I VEGAPULS C 21 PSC22.ab-c-d- N -f-g-h-I VEGAPULS C 22 PSC23.ab-c-d- N -f-g-h-I VEGAPULS C 23 PS21.ab-c-d- N -f-g-h-I VEGAPULS 21 PS31.ab-c-d- N -f-g-h-I VEGAPULS 31 KEY FOR VEGAPULS C 21 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignitionproof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as; X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Thread process side / Cable side, which can be displayed as; G Thread G1½ / G1 N Thread 1½NPT / 1NPT R Thread R1½ / R1 g = Cable material / Length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS C 22 ab = Explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, c-FM-us, c-CSA-us, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignition proof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as: X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Process fitting, which can be displayed as; G Thread G1½ N Thread 1½NPT R Thread R1½ g = Cable material / length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS C 23 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, RCM, EAC) VH ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 (Class II, III Division 1, 2) VB ATEX/UKEX/IEC; Gas, Encapsulation, Zone 1, 2 + Dust, Protection by enclosure, Zone 20, 21/22, 21, 22 SH EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 + Dust, intrinsic safety Zone 20, 20/21, 21, 22 SB EAC/SEPRO; Gas, encapsulation, Zone 1, 2 + Dust, encapsulation Zone 21, 22 TH CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, Intrinsic safety, Zone 20, 20/21, 21, 22 (not CCOE) TB CCOE, NEPSI, KTL, TIIS; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 (not CCOE) WH INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 + Dust, intrinsic safety, Zone 20, 20/21, 21, 22 WB INMETRO/IA; Gas, encapsulation, Zone 1, 2 + Dust, protection by enclosure, Zone 20, 21/22, 21, 22 FB c-FM-us/c-CSA-us; Gas, encapsulation, Zone 1, 2 (Class I Division 2) + Dust, protection by enclosure, Zone 20, 20/21, 21, 22 (Class II, III Division 1) FR c-FM-us/c-CSA-us; Gas, non-incendive, Class I Division 2 + Dust-ignitionproof, Class II, III Division 1 c = Approved as overfill protection, which can be displayed as; X without W with (WHG, VLAREM) d = Ship approval, which can be displayed as; X without S with (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff / Pharmaceutical certificate, which can be displayed as; X without N with (NSF/ANSI/CAN 61) P with (NIH) F with (FDA, EG1935/2004) f = Thread process side / Cable side, which can be displayed as; F Thread G1 M Thread 1NPT Q Thread R1 g = Cable material / length, which can be displayed as; A PUR / 5m (approx. 16ft) B PUR / 10m (approx. 32ft) H PUR / 15m (appr. 48ft) J PUR / 20m (appr. 64ft) C PUR / 25m (approx. 82ft) D PUR / individually selectable (acc. to CE, RCM, EAC) D PUR / individually selectable (acc. to c-FM-us, c-CSA-us) h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART W Four-wire Modbus S Three-wire SDI12 i = Sensor setting via smartphone and VEGA Tools app, which can be displayed as; X without B with KEY FOR VEGAPULS 21 / 31 ab = explosion protection, which can be displayed as; XX without, for Ex-free area (CE, UKCA, c-FM-us, c-CSA-us, RCM, EAC) AX without, for Ex-free area (CE, UKCA, RCM) VC ATEX/UKEX/IEC/c-FM-us/c-CSA-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) SC EAC/SEPRO; Gas, intrinsic safety; Zone 0, 0/1, 1, 2 TC CCOE/NEPSI/KTL/TIIS; Gas, Intrinsic safety, Zone 0, 0/1, 1, 2 WC INMETRO/IA; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 c = Approved as overfill protection, which can be displayed as; X Without W With (WHG, VLAREM) d = Ship approval, which can be displayed as; X Without S With (CCS, RINA, NK, ABS, DNV GL, LR, BV) N = Foodstuff/Pharmaceutical certificate, which can be displayed as X Without N With (NSF/ANSI/CAN 61) P With (NIH) F With (FDA, EG1935/2004) f = Process fitting, which can be displayed as; G Thread G1½ N Thread 1½NPT R Thread R1½ g = Cable entry / connection, which can be displayed as; M M20x1.5 / Cable gland PA black (ø5-9mm), standard h = Electronics, which can be displayed as; H Two-wire 4 ... 20 mA/HART i = Sensor setting via smartphone and VEGA Tools app X Without B With

Approval Holder:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
General Email
info.de@vega.com

View All Listings by this Company
Manufacturer:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
General Email
info.de@vega.com

View All Listings by this Company

Print This Approval


#240355059

'Sapphire Ceramic®'. Ivory coloured ceramic disc manufactured by sintering. For use with water up to 23°C.

Section:
5023 Ceramic
Expiry date:
31/03/2029

Approval Holder:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
General Email
info.de@vega.com

View All Listings by this Company

Print This Approval


#251202033

Range of stainless-steel pressure sensors. Maximum working pressures: B83.a-b-C5-3-f-g-h-i-j-k-l-m-n-o (Thread G1): 10.0 bar. B83.a-b-cd-e-f-g-h-i-j-k-l-m-n-o with METEC - metallic measuring cell: 25.0 bar, B83.a-b-cd-e-f-g-h-i-j-k-l-m-n-o with Piezoresistive - metallic measuring cell: 40.0 bar. Maximum operating temperature 100°C

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
B83.a-b-C5-3-f-g-h-i-j-k-l-m-n-o: 1” BSP (M). B83.a-b-LF-e-f-g-h-i-j-k-l-m-n-o: ½” NPT (M) & ¼” NPT (F). B83.a-b-D8/N8/D4/CQ/VE/CH-e-f-g-h-i-j-k-l-m-n-o: DN25, DN50 and DN80 flanged.
Marking:
VEGA on body. VEGA model, serial number, date of manufacture (YYYY) and other technical information on adhesive label or data plate on body.
Installation Requirements:
R001
Expiry date:
31/12/2030
Model:
VEGABAR 83 range: B83.a-b-cd-e-f-g-h-i-j-k-l-m-n-o a = Scope: • Not relevant for WRAS approval b = Approval: • Not relevant for WRAS approval cd = Process fitting / Material (NOTE - PN40 indicated below is possible maximum, the actual maximum working pressure is dictated by measuring cell, see entry ‘e’): • Material: 316L, Alloy C276 • Threads o C5: Thread G1, ISO228-1 / 316L (only Piezoresistive - metallic measuring cell) o LF: Thread ½NPT, innen ¼NPT, ASME B1.20.1 / 316L - D8: Flange DN25 PN40 Form C, EN1092-1/ 316/316L (only Piezoresistive - metallic measuring cell) - N8: Flange DN25 PN40 Form B1, EN1092-1 / 316/316L - D4: Flange DN50 PN40 Form C, EN1092-1/ 316/316L - CQ: Flange DN50 PN40 Form B1, EN1092-1 / 316/316L - VE: Flange DN80 PN40 Form C, EN1092-1 / 316/316L - CH: Flange DN80 PN40 Form B1, EN1092-1 / 316/316L e = Process temperature • Is up to the Process fitting and Material Thread C5 -> 3 (EPDM) High Temperature (METEC measuring cell): F, H, or T Low temperature (Piezoresistive - metallic measuring cell): S or E f = Pressure • Relative pressure (measurement against atmosphere) • Absolute pressure (measurement against vacuum) • Relative pressure climate-compensated (measurement against atmosphere) g = Measuring range • Not relevant for WRAS approval (maximum is 40 bar) h = Accuracy class • Different accuracy classes from 0.075 % to 0.20 % i = Electronics • Not relevant for WRAS approval j = Supplementary electronics • Not relevant for WRAS approval k = Housing • Not relevant for WRAS approval l = Housing version / Protection • Not relevant for WRAS approval m = Cable entry / Connection • Not relevant for WRAS approval n = Display/adjustment module PLICSCOM • Not relevant for WRAS approval o = Certificates • M – Yes o Foodstuff/Pharmaceutical certificate: WRAS

Approval Holder:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
General Email
info.de@vega.com

View All Listings by this Company
Manufacturer:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
General Email
info.de@vega.com

View All Listings by this Company

Print This Approval


#260302018

Range of pressure sensors with stainless steel bodies, EPDM ‘O’-ring and ceramic measuring cell. Maximum working pressure 25.0 bar. Cold water use only.

Section:
1530 Miscellaneous Fittings
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
B82.a-b-LF-e-f-g-h-i-j-k-l-m-n-o-p & B28/B38.ab-c-d-LF-g-h-i-j-k: ½” NPT (M) ¼” NPT inside (F). B82.a-b-CS-e-f-g-h-i-j-k-l-m-n-o-p & B28/B38.ab-c-d-CS-g-h-i-j-k: ½” BSP (M). B82.a-b-C5-e-f-g-h-i-j-k-l-m-n-o-p & & B28/B38.ab-c-d-C5-g-h-i-j-k: 1” BSP (M). B82.a-b-N7/B2/BC/B5/D8/N8/4G/D4/TP/CQ/5O/U8/U6/CH/PX/VE-e-f-g-h-i-j-k-l-m-n-o-p: DN25, DN50 and DN80 flanged.
Marking:
B82 models: VEGA on body. VEGA, model, serial number, date of manufacture (YYYY) and other technical information on adhesive label or data plate on body. B28/38 models: VEGA, serial number, date of manufacture (YYYY) and other technical information on body.
Installation Requirements:
R001
Expiry date:
31/03/2031
Model:
VEGABAR 82 range: B82.a-b-cd-e-f-g-h-i-j-k-l-m-n-o-p a = Scope: A - Europe I - worldwide V - Combination (Europe, world-wide) b = Approval: • X - for Ex-free area • W - Overfill protection (WHG, VLAREM) • M - Ship approval (DNV, BV, ABS, CCS, LR, RINA, ClassNK) • M - Ship approval (DNV, BV, ABS, CCS, LR, RINA, ClassNK) incl. MED • C - ATEX/UKEX II 1G, 1/2G, 2G Ex ia IIC T6 • U - ATEX/UKEX II 1G, 1/2G, 2G Ex ia IIC T6 + Overfill protection (WHG, VLAR EM) • O - ATEX/UKEX II 1G, 1/2G, 2G Ex ia IIC T6 + Ship approval • O - ATEX/UKEX II 1G, 1/2G, 2G Ex ia IIC T6 + ship approval incl. MED • H - ATEX/UKEX II 1G, 1/2G, 2G Ex ia IIC T6 + II 1D, 1/2D, 1/3D, Ext IIIC T* • T - ATEX/UKEX II 1G, 1/2G, 2G Ex ia IIC T6 + 1/2/-D Ex t IIIC IP67/I66 • E - ATEX/UKEX II 1/2G, 2G Ex d IIC T6 • Z - ATEX/UKEX II 1/2G, 2G Ex d IIC T6 + Overfill protection (WHG, VLAREM) • Q - ATEX/UKEX II 1/2G, 2G Ex d IIC T6 + Ship approval • Q - ATEX/UKEX II 1/2G, 2G Ex d IIC T6 + ship approval incl. MED • J - ATEX/UKEX II 1/2G, 2G Ex d IIC T6 + II 1D, 1/2D, 1/3D, 2D Ext IIIC T* • R - ATEX/UKEX II 1D, 1/2D, 1/3D, 2D Ext IIIC T* • S - ATEX/UKEX II 1/2/-D Ex t IIIC IP67/IP66 T* Da/Db/- • C - IEC Ex ia IIC T6 • U - IEC Ex ia IIC T6 + Overfill protection (WHG, VLAREM) • IEC Ex ia IIC T6 + Ship approval • H - IEC Ex ia IIC T6 + IEC Ex t IIIC T* • T - IEC Ex ia IIC T6 + IECEx Ex ia/ia/-, ia/tb ia IIC TX°C Da/Db/-, Da/Db • D - IEC Ex d ia IIC T6 • P - IEC Ex d ia IIC T6 + Ship approval • I - IEC Ex d ia IIC T6 + IEC Ex t IIIC T* • E - IEC Ex d IIC T6 • Q - IEC Ex d IIC T6 + Ship approval • J - IEC Ex d IIC T6 + IEC Ex t IIIC T* • R - IEC Ex t IIIC T* • S - IEC Ex ia/ia/-, ia/tb ia IIIC TX°C Da/Db/-, Da/Db • C - ATEX / IEC II 1G, 1/2G, 2G Ex ia IIC T6 / Ex ia IIC T6 • O - ATEX / IEC II 1G, 1/2G, 2G Ex ia IIC T6 / Ex ia IIC T6 + Ship approval • E - ATEX / IEC II 1/2G, 2G Ex d IIC / Ex d IIC T6 cd = Process fitting / Material (NOTE: PN rating relates to the flange and not the products maximum working pressure): • LF - Thread ½NPT, inside ¼NPT, ASME B1.20.1 / 316L • CS - Thread G½, ISO228-1, inside ø 11.4mm / Duplex (1.4462) • C5 - Thread G1, ISO228-1 / 316L • N7 - Flange DN25 PN40 Form C, DIN2501 / 316/316L • B2 - Flange DN50 PN40 Form C, DIN2501 / 316/316L • BC - Flange DN50 PN40 Form B, DIN2501 / 316/316L • B5 - Flange DN80 PN40 Form C, DIN2501 / 316/316L • D8 - Flange DN25 PN40 Form C, EN1092-1 / 316/316L • N8 - Flange DN25 PN40 Form B1, EN1092-1 / 316/316L • 4G - Flange DN25 PN40 Form B1, EN1092-1 / Duplex (1.4462) • D4 - Flange DN50 PN40 Form C, EN1092-1 / 316/316L • TP - Flange DN50 PN40 Form B1, EN1092-1 / 1.4435 (BN2) • CQ - Flange DN50 PN40 Form B1, EN1092-1 / 316/316L • 5O - Flange DN50 PN40 Form B1, EN1092-1 / Duplex (1.4462) • U8 - Flange DN50 PN40 Form B1, EN1092-1 / 1.4435 (BN2), (Ra<0.38μm) • U6 - Flange DN80 PN40 Form B1, EN1092-1 / 1.4435 (BN2), (Ra<0.38μm) • CH - Flange DN80 PN40 Form B1, EN1092-1 / 316/316L • PX - Flange DN80 PN40 Form B1, EN1092-1 / Duplex (1.4462) • VE - Flange DN80 PN40 Form C, EN1092-1 / 316/316L e = Sealing concept: • D – Double Seal f = Measuring cell seal / Process temperature • D - EPDM • E - EPDM g = Pressure • Relative pressure (measurement against atmosphere) • Absolute pressure (measurement against vacuum) • Relative pressure climate-compensated (measurement against atmosphere) h = Measuring range • Absolute: 0...+0.025 bar to 0...+25.0 bar • Relative: -1...0.0 bar to -1...+25.0 bar i = Accuracy class • Different accuracy classes from 0.05 % to 0.20 % j = Electronics • Z - Two-wire 4 ... 20 mA • H - Two-wire 4 ... 20 mA/HART • U - Four-wire Modbus (converter in second chamber) • A - Two-wire 4 ... 20 mA/HART with SIL qualification • P - Two-wire Profibus PA • F - Two-wire Foundation Fieldbus • S - Secondary electronics for electronic differential pressure • T - Secondary electronics for electronic differential pressure with SIL qualification k = Supplementary electronics • X - without • Z - Additional current output 4 ... 20 mA l = Housing • K - Plastic single chamber • R - Plastic double chamber • A - Aluminium single chamber • D - Aluminium double chamber • V - Stainless steel single chamber (precision casting) • W - Stainless steel double chamber (precision casting) • 8 - Stainless steel single chamber (electropolished) m = Housing version / Protection I - compact / IP66/IP67; TYPE 4X • D - compact / IP66/IP68 (0.2bar); TYPE 6P • P - compact / IP66/IP67; TYPE 4X with M12x1 for VEGADIS 81 • N - compact / IP66/IP68 (1bar); TYPE 6P • M - compact / IP67/IP69 TYPE 4X • A - Axial cable outlet IP68 (PUR) with external housing / IP66/IP67; TYPE 4X • C - Lateral cable outlet IP68 (PUR) with external housing / IP66/IP67; TYPE 4X • K - Axial cable outlet IP68 (PE) with external housing / IP66/IP67; TYPE 4X • L - Lateral cable outlet IP68 (PE) with external housing / IP66/IP67; TYPE 4X • T - Cable outlet / IP66/IP67 TYPE 4X n = Cable entry / Connection • M - M20x1.5 / Cable gland PA black (ø5-9mm), standard • S - M20x1.5 / Cable gland PA black (ø6-12mm) • T - M20x1.5 / Cable gland PA black (ø10-14mm) • K - M20x1.5 / Cable gland PA blue (ø5-9mm) • U - M20x1.5 / Cable gland PA blue (ø6-12mm) • V - M20x1.5 / Cable gland PA blue (ø10-14mm) • L - M20x1.5 / Cable gland stainless steel (ø7-12mm) • O - M20x1.5 / Cable gland brass nickel-plated (ø6-12mm) • 2 - M20x1.5 / Cable gland brass nickel-plated (ø5-9mm) • 9 - M20x1.5 / Cable gland brass nickel-plated SFLU10-M (ø6-12mm) • D - M20x1.5 / Blind plug • 1 - M20x1.5 / without • 6 - M20x1.5 / Cable gland brass nickel-plated; for shielded cable (ø9-13mm) • N - ½NPT / Blind plug • Q - ½NPT / without • J - ½NPT / Cable gland PA black (ø5-9mm) • 8 - ½NPT / Cable gland brass nickel-plated; for reinforced cable (ø9-13mm) • P - ½NPT / Cable gland brass nickel-plated (ø6-12mm) • C - M20x1.5 / Plug connector M12x1, assignment A • B - M20x1.5 / Plug connector M12x1, assignment B • R - M20x1.5 / Plug connector M12x1, assignment C • I - M20x1.5 / Plug connector acc. to ISO4400 • F - M20x1.5 / Plug connector Harting HAN 7D (straight) • G - M20x1.5 / Plug connector Harting HAN 7D (bent) • H - M20x1.5 / Plug connector Harting HAN 8D (straight) • W - M20x1.5 / Plug connector Harting HAN 8D (bent) • Z - ½NPT / Plug 7/8NPT o = Display/adjustment module PLICSCOM • X - without • A - mounted • F - without; lid with inspection window • H - mounted, with heating • B - laterally mounted • K - mounted; with Bluetooth, magnetic pen operation • L - laterally mounted; with Bluetooth, magnetic pen operation p = Certificates • M – Yes o Foodstuff/Pharmaceutical certificate: ▪ WRAS VEGABAR 28 range: B28.ab-c-d-ef-g-h-i-j-k ab = Explosion protection: • XX - for Ex-free area (CE, UKCA, RCM, c-UL-us) • VA - ATEX/UKEX; Gas, increased safety, Zone 2: II 3G Ex ec IIC T4 Gc • VC - ATEX/UKEX/IEC/c-UL-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) • VR - ATEX/IEC/c-UL-us; Gas, intrinsic safety (Class I Division 1,2), Zone 0, 0/1, 1, 2 + dust, protection by enclosure, Zone 20, 20/21, 21 (Class II Division 1) (in preparation: UKEX) • XX - for Ex-free area (EAC) c = Ship approval: • S - with (DNV, LR, ABS, RINA, CCS, NK, BV) • X - without d = Foodstuff/Pharmaceutical certificate • W - with (WRAS) ef = Process fitting / Material: • LF - Thread ½NPT, inside ¼NPT, ASME B1.20.1 / 316L • CS - Thread G½, ISO228-1, inside ø 11.4 mm / Duplex (1.4462) • C5 - Thread G1, ISO228-1; front-flush / 316L g = Measuring cell seal / Process temperature: • D - EPDM h = Measuring range: • Different measuring ranges – both absolute and relative. • Starting from 0…+0.1 bar up to 0…+25.0 bar i = Electrical connection / Protection: • M - M12x1 plastic/ IP66/IP67/IP69 • E - M12x1 stainless steel / IP66/IP67/IP69 • S - 4-pole plug connection ISO4400 M16 / IP65 • K - 4-pole plug connection with hinged cover ISO4400 / IP 65 • T - with direct cable outlet / IP66/IP68 (0.5bar) • V - with direct cable outlet of stainless steel / IP66/68 (0.5bar) j = Electronics: • Z - Two-wire: 4...20 mA • C - Three-wire: transistor, 4...20 mA (active) • A - Three-wire: IO-Link, transistor, 4...20 mA (active) k = Sensor setting via smartphone and VEGA Tools app: • B - with • X - without VEGABAR 38 range: B38.ab-c-d-ef-g-h-i-j-k ab = Explosion protection: • XX - for Ex-free area (CE, UKCA, RCM, c-UL-us) • VC - ATEX/UKEX/IEC/c-UL-us; Gas, intrinsic safety, Zone 0, 0/1, 1, 2 (Class I Division 1, 2) • XX - for Ex-free area (EAC) c = Ship approval: • S - with (DNV, LR, ABS, RINA, CCS, NK, BV) • X - without d = Foodstuff/Pharmaceutical certificate • W - with (WRAS) ef = Process fitting / Material: • LF - Thread ½NPT, inside ¼NPT, ASME B1.20.1 / 316L • CS - Thread G½, ISO228-1, inside ø 11.4 mm / Duplex (1.4462) • C5 - Thread G1, ISO228-1; front-flush / 316L g = Measuring cell seal / Process temperature: • D - EPDM h = Measuring range: • Different measuring ranges – both absolute and relative. • Starting from 0…+0.1 bar up to 0…+25.0 bar i = Electrical connection / Protection: • M - M12x1 / IP66/IP67 • S - 4-pole plug connection ISO4400 M16 / IP65 • K - 4-pole plug connection with hinged cover ISO4400 / IP 65 j = Electronics: • Z - Two-wire: 4...20 mA • C - Three-wire: transistor, 4...20 mA (active) • A - Three-wire: IO-Link, transistor, 4...20 mA (active) k = Sensor setting via smartphone and VEGA Tools app: • B - with • X - without

Approval Holder:
VEGA Grieshaber KG
Company Name
VEGA Grieshaber KG
Address
Am Hohenstein 113 Schiltach
Postcode
77761
General Email
info.de@vega.com

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.