Xylem Service Italia S.r.l Approvals


#2112045

‘ECOCIRC XL N’ & ‘ECOCIRC XL PLUS N’ range of circulation pumps with stainless steel bodies, plastic impellers, and EPDM ‘O’-rings. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
2112045
Size:
1½”-2” BSP (M). DN32-65 flanged.
Marking:
Lowara (brand of Xylem) and Lowara logo, manufacturer name (xylem brand) and technical information on adhesive label on top of pump.
Installation Requirements:
R001
Expiry date:
31/12/2026
Model:
ECOCIRC-XL N X1-X2 X3 X4 & ECOCIRC-XL PLUS N X1-X2 X3 X4. Where: ECOCIRC XL = series name. PLUS = with communication capabilities. N = stainless steel. X1 = port nominal diameter in mm (25 or 32 threaded models, where 25 = 1½” BSP (M), 32 = 2” BSP (M), 32-65 on flanged models). X2 = maximum head in m x 10. X3 = maximum flow - low flow versions - ‘empty’ = standard version. X4 = flange type - F = flanged, ‘empty’ = threaded BSP (M). Examples: ECOCIRC-XL N 25-40 & ECOCIRC XL PLUS N 65-120F.

Approval Holder:
Xylem Service Italia S.r.l
Company Name
Xylem Service Italia S.r.l
Address
Via Vittorio Lombardi 14, 36075 Montecchio Maggiore-Alte Ceccato VI, Vicenza
Phone
0039 0444 707111

View All Listings by this Company
Manufacturer:
Xylem Service Hungary Kft.
Company Name
Xylem Service Hungary Kft.
Address
Külso-Kátai út. 41 HU-2700 Cegléd
Phone
+36-53-510502

View All Listings by this Company

Print This Approval


#240502064

Range of electronic pressure switches housed in a plastic body with a ceramic sensor and NBR gaskets and/or ‘O’-rings. The 1091203260 & G0912026 models incorporate a spring-loaded plastic flow restrictor. Maximum working pressure 12.0 bar. Cold water only.

Section:
1720 Switches
Section Subtitle:
Pressure operated.
WRAS Approval Number:
240502064
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
G01912025 GENYO PLUS 16/A RO.5-8 110-230 V 109120250 GENYO PLUS 16/A RO.5-8 110-230 V ¼" BSPP (F). 109120260 GENYO PLUS TKIT 16/A RO.5-8 LOWARA G09120260 GENYO PLUS TKIT 16/A RO.5-8 GWT 1" BSPP (M) X 1" BSPP (F) X 1" BSPP (F).
Marking:
Genyo and product name on body. Model type serial number including date of manufacture (XX - YY/WWW VXX, where W13 would = week 13) and other technical information on adhesive label on body.
Installation Requirements:
R001
Expiry date:
31/05/2029
Model:
RANGE OF ELECTRONIC PRESSURE SWITCHES: G01912025 GENYO PLUS 16/A RO.5-8 110-230 V 109120250 GENYO PLUS 16/A RO.5-8 110-230 V 109120260 GENYO PLUS TKIT 16/A RO.5-8 LOWARA G09120260 GENYO PLUS TKIT 16/A RO.5-8 GWT

Approval Holder:
Xylem Service Italia S.r.l
Company Name
Xylem Service Italia S.r.l
Address
Via Vittorio Lombardi 14, 36075 Montecchio Maggiore-Alte Ceccato VI, Vicenza
Phone
0039 0444 707111

View All Listings by this Company

Print This Approval


#240206701

Range of horizontal or vertical multi-stage pumps with a stainless-steel body (HM models) or cast iron body with blue coloured cationic resin coating (VM models), incorporating either plastic or stainless-steel impellers (see model), stainless steel sleeve, EPDM gaskets and seals. Maximum working pressure 10.0 bar / 16.0 bar (see models). Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240206701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
HM models: 1” - 2” BSP (F) VM models: 1¼” - 1½” BSP (F).
Marking:
Lowara or Goulds Water Technology (both brands of Xylem), manufacturer and address, model number, serial number, maximum working pressure and technical information on adhesive label on body.
Installation Requirements:
R001 R415
Expiry date:
28/02/2029
Model:
1HM, 3HM, 5HM, 10HM, 15HM & 22HM. 1VM, 3VM, 5VM & 10VM. Model nomenclature: W XXX YY Z EM Where: W - flow rate (m3/h), either 1, 3, 5, 10, 15, or 22. XXX - Model type: Horizontal (HM) or Vertical (VM) mode, where last (optional) digit can denote the variable speed drive as follows: Null = standard asynchronous motor, H = equipped with Hydrovar, X = other drives, E = e-SM. YY - Number of impellers/stages HM models: 2-25 stages only (02-25), VM models: 2-8 stages only (02-08). Z - Material, where: (P) is plastic impeller and SS AISI 304 body (HM & VM models), (S) is SS AISI 304 impeller and body (HM models only), (N) is SS AISI 316 impeller and body (HM models only). E = 5 - 6 digits for electrical specification. M = 3 digits, where: 1st digit: Mech. rotary seal - V = Aluminium oxide (Ceramic), or Mech. rotary seal - Q = Silicon carbide (Ceramic). 2nd digit: Mech. stationary seal - B = Carbon resin impregnated. 3rd digit: Mech. seal elastomers - E = EPDM. Example code: 1HM03P05M5HVBE. Max Working Pressure for VM models → 10 bar. Max Working Pressure for HM models with stainless steel impellers and QBE Mechanical Seal → 16 bar (Depending on number of stages - see below), Max Working Pressure for HM models with plastic impellers and/or VBE Mechanical Seal → 10 bar (Depending on number of stages - see below). 1HM (P)/(S)/(N) 1-16 stages - 10.0 bar, 1HM (S)/(N) 18-25 stages - 16.0 bar. 3HM (P)/(S)/(N) 1-13 stages - 10.0 bar, 3HM (S)/(N) 14-21 stages - 16.0 bar. 5HM (P)/(S)/(N) 1-13 stages - 10.0 bar, 5HM (S)/(N) 14-21 stages - 16.0 bar. 10HM (P)/(S)/(N) 1-8 stages - 10.0 bar, 10HM (S)/(N) 9-13 stages - 16.0 bar. 15HM (S)/(N) 2-7 stages - 10.0 bar, 22HM (S)/(N) 2-5 stages - 10.0 bar.

Approval Holder:
Xylem Service Italia S.r.l
Company Name
Xylem Service Italia S.r.l
Address
Via Vittorio Lombardi 14, 36075 Montecchio Maggiore-Alte Ceccato VI, Vicenza
Phone
0039 0444 707111

View All Listings by this Company
Manufacturer:
Lowara S.r.l | Xylem Service Italia S.r.l | Xylem Manufacturing Middle East Region FZCO Dubai | Xylem Water Systems International Philippines Inc.
Company Name
Lowara S.r.l | Xylem Service Italia S.r.l | Xylem Manufacturing Middle East Region FZCO Dubai | Xylem Water Systems International Philippines Inc.
Address

View All Listings by this Company

Print This Approval


#240202717

Range of multistage pumps with stainless steel bodies, impellers, shaft and outer sleeve. SC family models are submersible pumps. SCD family models are surface pumps only. SCDS family models can be used either as a surface pump or as a submersible pump. SCD/SCDS models: Maximum working pressure 10.0 bar. SC models: Open outlet use only. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
240202717
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
SC models: Suction fed inlet x 1¼" BSP (F) outlet. SCD/SCDS models: 1¼" BSP (F) inlet/outlet.
Marking:
Xylem, Lowara, CE, model and other technical information on data plate on body.
Installation Requirements:
R001 R415
Expiry date:
28/02/2029
Model:
Model Code: XAAY/ZZ/F Where: X denotes the flow rate: This can be any digit 1 to 8. AA denotes the family code: SC (without float switch option only). SCD. SCDS (without float switch option only). Y denotes the stages: This can be any digit 2 to 9. ZZ/F: all the subsequent digits/letters are related to electrical features.

Approval Holder:
Xylem Service Italia S.r.l
Company Name
Xylem Service Italia S.r.l
Address
Via Vittorio Lombardi 14, 36075 Montecchio Maggiore-Alte Ceccato VI, Vicenza
Phone
0039 0444 707111

View All Listings by this Company

Print This Approval


#2302569

'Ball Nest (PTFE Teflon p/n FR 101-1)'. White coloured (opaque), compression moulded PTFE component. For use with water up to 85°C.

Section:
5294 Polytetrafluoroethylene (PTFE)
Section Subtitle:
Components.
WRAS Approval Number:
2302569
Expiry date:
29/02/2028

Approval Holder:
Xylem Service Italia S.r.l
Company Name
Xylem Service Italia S.r.l
Address
Via Vittorio Lombardi 14, 36075 Montecchio Maggiore-Alte Ceccato VI, Vicenza
Phone
0039 0444 707111

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1 of 2

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.