Xylem Service Italia S.r.l Approvals


#2302569

'Ball Nest (PTFE Teflon p/n FR 101-1)'. White coloured (opaque), compression moulded PTFE component. For use with water up to 85°C.

Section:
5294 Polytetrafluoroethylene (PTFE)
Section Subtitle:
Components.
WRAS Approval Number:
2302569
Expiry date:
29/02/2028

Approval Holder:
Xylem Service Italia S.r.l
Company Name
Xylem Service Italia S.r.l
Address
Via Vittorio Lombardi 14, 36075 Montecchio Maggiore-Alte Ceccato VI, Vicenza
Phone
0039 0444 707111

View All Listings by this Company

Print This Approval


#2302570

'Silicone Rubber Washer SIL40 (SIL4001)'. Black coloured, vulcanised silicone rubber washer. Shore hardness 40. Tested in-radius size 0.56mm. For use with water up to 85°C.

Section:
5410 Rubbers
Section Subtitle:
Silicone - components.
WRAS Approval Number:
2302570
Expiry date:
29/02/2028

Approval Holder:
Xylem Service Italia S.r.l
Company Name
Xylem Service Italia S.r.l
Address
Via Vittorio Lombardi 14, 36075 Montecchio Maggiore-Alte Ceccato VI, Vicenza
Phone
0039 0444 707111

View All Listings by this Company

Print This Approval


#250702701

Range of cold-water supply booster sets, incorporating a stainless-steel manifold system and between 1 and 3 pumps. The booster sets also incorporate spherical valves, non-return valves (not suitable for backflow protection), pressure switches/sensors and expansion vessels. Maximum working pressure: 16.0 Bar. Cold water use only.

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
250702701
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Inlet: 1” BSP, 1 ¼” BSP, 1 ½” BSP, 2” BSP, 2 ½” BSP, 3” BSP & DN100 (flanged). Outlet: 1” BSP, 1 ¼” BSP, 1 ½” BSP, 2” BSP, 2 ½” BSP, 3” BSP, DN80 (flanged) & DN100 (flanged).
Marking:
LOWARA, Model name and product information on adhesive label on control panel
Installation Requirements:
R001 R415
Expiry date:
31/07/2030
Model:
SMB / VV / YYYYYYYYYYYY / W / XX / ZZZ SMB - Series of booster - Variable speed Drive SM VV- Number of pumps installed: 10=1 PUMP 20=2 PUMPS 30=3 PUMPS YYYYYYYYYYY -Type of pumps installed: from 1SVE up to 22SVE from 1HME up to 15HME W - Main voltage supply 4=3*400Vac 2=1*230Vac 3=3*230Vac XX - Option CP=free voltage contacts ZZZ - Option PMA=pressure switch on suction

Manufacturer:
Xylem Service Italia S.r.l
Company Name
Xylem Service Italia S.r.l
Address
Via Vittorio Lombardi 14, 36075 Montecchio Maggiore-Alte Ceccato VI, Vicenza
Phone
0039 0444 707111

View All Listings by this Company

Print This Approval


#250702702

Range of cold-water supply booster sets, incorporating a stainless-steel manifold system and between 1 and 4 pumps depending on model. The booster sets also incorporate spherical valves and non-return valves. Maximum working pressure 16.0 Bar Maximum operating temperature 23.0°C

Section:
1610 Pumps
Section Subtitle:
Wholesome water use.
WRAS Approval Number:
250702702
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Manifold size is dependent on pump type and number of pumps, as shown below: Pump Type, No. of Pumps, Inlet Size, Outlet Size 1SV, 1, 1" BSP (M), 1" BSP (M) 1SV, 2, 2" BSP (M), 2" BSP (M) 1SV, 3, 2" BSP (M), 2" BSP (M) 1SV, 4, 2" BSP (M), 2" BSP (M) 3SV, 1, 1" BSP (M), 1" BSP (M) 3SV, 2, 2" BSP (M), 2" BSP (M) 3SV, 3, 2" BSP (M), 2" BSP (M) 3SV, 4, 2" BSP (M), 2" BSP (M) 5SV, 1, 1.1/4" BSP (M), 1.1/4" BSP (M) 5SV, 2, 2" BSP (M), 2" BSP (M) 5SV, 3, 2" BSP (M), 2" BSP (M) 5SV, 4, 2.1/2" BSP (M), 2.1/2" BSP (M) 10SV, 1, 1.1/2" BSP (M), 1.1/2" BSP (M) 10SV, 2, 2.1/2" BSP (M), 2.1/2" BSP (M) 10SV, 3, 3" BSP (M), 3" BSP (M) 10SV, 4, 3" BSP (M), 3" BSP (M) 15SV, 1, 2" BSP (M), 2" BSP (M) 15SV, 2, 3" BSP (M), 3" BSP (M) 15SV, 3, DN100 Flanged, DN100 Flanged 15SV, 4, DN125 Flanged, DN100 Flanged 1HM, 1, 1" BSP (M), 1" BSP (M) 1HM, 2, 2" BSP (M), 2" BSP (M) 1HM, 3, 2" BSP (M), 2" BSP (M) 1HM, 4, 2" BSP (M), 2" BSP (M) 3HM, 1, 1" BSP (M), 1" BSP (M) 3HM, 2, 2" BSP (M), 2" BSP (M) 3HM, 3, 2" BSP (M), 2" BSP (M) 3HM, 4, 2" BSP (M), 2" BSP (M) 5HM, 1, 1.1/4" BSP (M), 1" BSP (M) 5HM, 2, 2" BSP (M), 2" BSP (M) 5HM, 3, 2" BSP (M), 2" BSP (M) 5HM, 4, 2.1/2" BSP (M), 2.1/2" BSP (M) 10HM, 1, 1.1/2" BSP (M), 1.1/4" BSP (M) 10HM, 2, 2.1/2" BSP (M), 2.1/2" BSP (M) 10HM, 3, 2.1/2" BSP (M), 2.1/2" BSP (M) 10HM, 4, 3" BSP (M), 3" BSP (M) 15HM, 1, 2" BSP (M), 1.1/2" BSP (M) 15HM, 2, 3" BSP (M), 3" BSP (M) 15HM, 3, DN100 Flanged, DN80 Flanged 15HM, 4, DN100 Flanged, DN100 Flanged 22HM, 1, 2" BSP (M), 1.1/2" BSP (M) 22HM, 2, 3" BSP (M), 3" BSP (M) 22HM, 3, DN100 Flanged, DN100 Flanged 22HM, 4, DN125 Flanged, DN100 Flanged 22SV, 1, 2" BSP (M), 2" BSP (M) 22SV, 2, 3" BSP (M), 3" BSP (M) 22SV, 3, DN100 Flanged, DN100 Flanged 22SV, 4, DN125 Flanged, DN100 Flanged
Marking:
Lowara logo, Xylem services and model code on adhesive label on body
Installation Requirements:
R001 R415
Expiry date:
31/07/2030
Model:
Model Code: GHV VV / YYYYYYYYYYYY / W / XX / ZZZ GHV - Series of booster - Variable speed Drive EXM or HVL VV denotes the number of pumps installed, and can be replaced with any of the following: 10 = 1 Pump 20 = 2 Pumps 30 = 3 Pumps 40 = 4 Pumps YYYYYYYYYYYY denotes the type of pumps installed and can be replaced with any of the following: 1SV up to 22SV 1HM up to 22HM W denotes the main voltage supply and can be replaced with any of the following: 4=3*400Vac 2=1*230Vac 3=3*230Vac XX -denotes the option and can be replaced with: CP = free voltage contacts Blank = option not chosen ZZZ denotes the option for a pressure switch on suction and can be replaced with: PMA = pressure switch on suction Blank = option not chosen

Manufacturer:
Xylem Service Italia S.r.l
Company Name
Xylem Service Italia S.r.l
Address
Via Vittorio Lombardi 14, 36075 Montecchio Maggiore-Alte Ceccato VI, Vicenza
Phone
0039 0444 707111

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2 of 2

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.