#2003017

Double check valve assembly consisting of two spring loaded resilient trim in-line check valve cartridges housed in a DZR brass body. Maximum working pressure 10.0 bar. Maximum operating temperature 85ºC.

Section:
0032 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Type EC - Verifiable double check valve.
WRAS Approval Number:
2003017
Expiry date:
31/03/2025
Size:
54mm compression
Marking:
V&G, WRAS, size, CR, flow arrow and date of manufacture (MM/YY) on valve body.
Installation Requirements:
R001
Model:
12.10152.054.CP5R
Manufacturer:
Zhejiang Valogin Technology Co. Ltd.
Company Name
Zhejiang Valogin Technology Co. Ltd.
Address
Qinggang Technological Ind. Zone, Yuhuan, Zhejiang

View All Listings by this Company

Print This Approval


#2005013

Range of double check valve assemblies consisting of two spring loaded in-line check valve cartridges housed in a DZR brass or chrome plated DZR brass (CP02-8511 suffix models) body with a drain port between the cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
0034 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Type ED - Non-verifiable double check valve.
WRAS Approval Number:
2005013
Expiry date:
31/05/2025
Note:
Not for use with water injected with CO2 gas.
Size:
See model.
Marking:
V&G logo, WRAS, size, CR and flow arrow on body. (V&G is a registered trademark of Zhejiang Valogin Technology Co. Ltd)
Installation Requirements:
R001
Model:
12.10152.015.CP02-8511: 15mm compression inlet/outlet, 12.10152.015.CP5R-8511: 15mm compression inlet/outlet, 12.10152.022.CP02-8511: 22mm compression inlet/outlet, 12.10152.022.CP5R-8511: 22mm compression inlet/outlet, 12.10112.035.CP5R-8511: 35mm compression inlet/outlet.
Manufacturer:
Zhejiang Valogin Technology Co. Ltd.
Company Name
Zhejiang Valogin Technology Co. Ltd.
Address
Qinggang Technological Ind. Zone, Yuhuan, Zhejiang

View All Listings by this Company

Print This Approval


#2007347

Range of Y-pattern strainers with DZR brass bodies and stainless steel strainers. Maximum working pressure 20 bar (BSP threaded models ½”-2”), 16.0 bar (BSP threaded models 2½”-3” and compression models). Maximum operating temperature 85°C.

Section:
1715 Strainers
WRAS Approval Number:
2007347
Expiry date:
31/07/2025
Size:
½”-3” BSP (F). 15 & 22mm compression.
Marking:
V&G (trademark of Zhejiang Valogin Technology Co. Ltd.), PN, size, WRAS, CR, flow arrow and date of manufacture (MMYY) on body.
Installation Requirements:
R001 R120
Model:
BSP threaded models: 17.30822.R15.CP5R-8511. 17.30822.R20.CP5R-8511. 17.30822.R25.CP5R-8511. 17.30822.R32.CP5R-8511. 17.30822.R40.CP5R-8511. 17.30822.R50.CP5R-8511. 17.30802.R65.CP5R-8511. 17.30802.R80.CP5R-8511. Compression models: 17.30222.015.CP5R-8511. 17.30222.022.CP5R-8511.
Manufacturer:
Zhejiang Valogin Technology Co. Ltd.
Company Name
Zhejiang Valogin Technology Co. Ltd.
Address
Qinggang Technological Ind. Zone, Yuhuan, Zhejiang

View All Listings by this Company

Print This Approval


#2010315

Range of non-verifiable double check valve assemblies with DZR brass bodies, incorporating two spring loaded, resilient trim in-line check valve cartridges. Maximum working pressure 10.0 bar. Maximum operating temperature 85°C.

Section:
0034 Backflow Prevention Devices
Section Subtitle:
SCHEDULE 2 - Section 6.2 Type ED - Non-verifiable double check valve.
WRAS Approval Number:
2010315
Expiry date:
31/10/2025
Size:
See model.
Marking:
V&G, WRAS, Size, DR, flow arrow and date of manufacturer (MM-YY) on body.
Installation Requirements:
R001
Model:
12.10172.028.CP5R-8511 – 28mm compression 12.10172.042.CP5R-8511 – 42mm compression
Manufacturer:
Zhejiang Valogin Technology Co. Ltd.
Company Name
Zhejiang Valogin Technology Co. Ltd.
Address
Qinggang Technological Ind. Zone, Yuhuan, Zhejiang

View All Listings by this Company

Print This Approval


#2104051

Range of wall mounted hose union taps (brass, chrome plated brass or DZR brass body) incorporating a non-rising spindle headwork with a butterfly handle operating member. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union, metal. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2104051
Expiry date:
30/04/2026
Size:
¾” BSP male inlet x 19mmØ hose outlet
Marking:
V&G, WRAS and size on body. Model 13.20202.G20.CP5R-8511 also has ‘DR’ on body.
Installation Requirements:
R001 R040
Model:
13.20202.G20.CP03-8510. 13.20202.G20.CP5R-8510. 13.20202.G20.CP5R-8511.
Manufacturer:
Zhejiang Valogin Technology Co. Ltd.
Company Name
Zhejiang Valogin Technology Co. Ltd.
Address
Qinggang Technological Ind. Zone, Yuhuan, Zhejiang

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2 of 6

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.