Y. Stern Engineering (1989) Ltd Approvals


#2212038

Range of single hole, single outlet, electronically controlled tap assemblies (chrome plated brass body). The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Supplied with a stainless steel braided PEX lined flexible connection hose and a manual lever for controlling the temperature. Maximum working pressure 8.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
2212038
Expiry date:
31/12/2027
Size:
½” BSP male
Marking:
Stern on top of body.
Installation Requirements:
R001 R006 R009 R010
Model:
239200 - Trendy 1000B, 239300 - Trendy 1000E, 239600 - Trendy 1000LB, 239700 - Trendy 1000LE, 239201 - Trendy 1000B AB1953, 239301 - Trendy 1000E AB1953, 239601 - Trendy 1000LB AB1953, 239701 - Trendy 1000LE AB1953.
Factor:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd 8122217 Yavne ISRAEL

View All Listings by this Company

Print This Approval


#2301014

Range of single hole, single outlet (fixed) electronically controlled tap assemblies (chrome plated brass bodies). Flow is controlled by a solenoid valve activated via an infra-red sensor. The temperature is controlled via a manual operating single lever on body. The inlets hose incorporates stainless steel strainer and an approved check valve cartridge (however, the complete assembly has not been fully tested to demonstrate that it provides backflow protection). The spout outlet incorporates a plastic aerator and the product is supplied with metal backnuts. Maximum working pressure 8.0 Bar

Non-metallic materials and components comply with BS6920 at 70°C

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
2301014
Expiry date:
31/01/2028
Size:
Stainless steel braided PEX lined flexible hose assemblies with 3/8" BSP captive nut end connections.
Marking:
Stern on top of tap body
Installation Requirements:
R001 R009 R006 R010
Model:
239250 – Trendy 1000 Plus B 239350 - Trendy 1000 Plus E 239260 - Trendy 1000 Plus LB 239360 - Trendy 1000 Plus LE 239251 - Trendy 1000 Plus B AB 1953 239351 - Trendy 1000 Plus E AB 1953 239261 - Trendy 1000 Plus LB AB 1953 239361 - Trendy 1000 Plus LE AB 1953
Factor:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd 8122217 Yavne ISRAEL

View All Listings by this Company

Print This Approval


#2207081

Latching solenoid valves with a plastic body and an EPDM diaphragm. The inlet incorporates a stainless-steel strainer. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
2240 Valves
Section Subtitle:
Solenoid, plastic.
WRAS Approval Number:
2207081
Expiry date:
31/07/2027
Size:
½” BSP (M) inlet/outlet.
Marking:
Stern, date of manufacture (WW/YY) on adhesive label on body. Stern Logo and flow arrow on body.
Installation Requirements:
R001
Model:
Electroflo latching solenoid valve
Factor:
Thomas Dudley Limited
Company Name
Thomas Dudley Limited
Address
Dauntless Works, PO Box 28, New Birmingham Road
Postcode
DY1 4SN

View All Listings by this Company
Manufacturer:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd 8122217 Yavne ISRAEL

View All Listings by this Company

Print This Approval


#2304020

Range of wall mounted, single-hole, single outlet (fixed) electronically controlled combination tap assemblies (chrome plated brass bodies). Flow is controlled via a solenoid, activated via an infra-red sensor. The outlets incorporate plastic aerators. Maximum working pressure 8.0 bar Maximum operating temperature 70°C

Non-metallic materials and components comply with BS6920 at 70°C

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
2304020
Expiry date:
30/04/2028
Size:
15 mm Spigot
Marking:
STERN logo on wall plate
Installation Requirements:
R001 R010 R040
Model:
237801 – Extreme CS B 237800 – Extreme CS E 237801-316 – Extreme CS B AISI316 237800-316 – Extreme CS E AISI316 237802 – Extreme CS DPB 237803 – Extreme CS DPE 237802-316 – Extreme CS DPB AISI316 237803-316 – Extreme CS DPE AISI316
Manufacturer:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd 8122217 Yavne ISRAEL

View All Listings by this Company

Print This Approval


#2309045

Range of single hole, single outlet, electronic touch free, deck mounted taps (chromium plated brass) for cold or premixed water. Flow is controlled via solenoid valves, actuated by infra-red sensors. Power is supplied by externally mounted 9V battery pack or 9V transformer. The inlet hoses have a stainless-steel strainer and the spout outlets incorporate plastic aerators. Maximum working pressure 8.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
2309045
Expiry date:
30/09/2028
Size:
Stainless steel braided, PEX lined hose with 3/8” BSP captive nut.
Marking:
Stern on operating member.
Installation Requirements:
R001 R006 R009
Model:
231000 Sensor B Standart 231100 Sensor E Standart 231530 Sensor LB Standart (extended spout) 231520 Sensor LE Standart (extended spout).
Factor:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd 8122217 Yavne ISRAEL

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 5 of 9

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.