Range of single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). Flow is controlled by a solenoid valve activated via infra-red sensor. The products are supplied with a stainless steel braided PEX lined flexible hose assembly to connect between the tap body and the solenoid valve. The spout outlets incorporate plastic aerators and the solenoid inlet incorporates a stainless steel strainer. Maximum working pressure 8.0 Bar. Maximum operating temperature 60°C.
`Prox and Wave` ranges of sensor operated flow control devices incorporating solenoid valves with acetal bodies, EPDM rubber diaphragms, stainless steel pins and plungers. The inlet incorporates a stainless-steel strainer. Maximum working pressure 8.0 bar. Maximum operating temperature 70°C.
Range of thermostatic blending valves (chromium plated brass body) with a thermostatic cartridge controlling the temperature. The inlets incorporate stainless steel strainers and approved single check valve cartridges however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 5.0 bar. Maximum operating temperature 60°C.
Wall mounted, two-hole, single outlet (fixed) combination tap assemblies (chromium plated brass) incorporating a quarter turn ceramic disc headwork, with dome type operating member, controlling the flow. Temperature is controlled independently via thermostatic cartridge with single lever operating member. The inlets incorporate stainless steel strainers and approved check valve cartridges however the complete product has not been fully tested to demonstrate It provides backflow protection. The spout outlets incorporate a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of electronically controlled, wall mounted, shower flow control devices with chromium plated brass bodies. The flow is controlled by a solenoid valve. The inlets of the products incorporate a stainless-steel strainer. Neptune 1011 is infrared operated. Perfect Time SH 1011 is touch operated. Maximum working pressure 8.0 bar. Maximum operating temperature 70°C.
Range of shower outlets (chromium plated brass). All model except SH5010 incorporate a flow regulator. Maximum operating temperature 60°C
Range of single hole, single outlet (fixed) electronically operated, tap assemblies (chromium plated brass). Flow is controlled via solenoid valve and actuated by a touch sensor. The spout outlets incorporate a plastic aerator, supplied with stainless steel strainers. Maximum working pressure 8.0 bar. Maximum operating temperature 60°C.
Range of latching and non-latching solenoid valves with a plastic body (all models, except for 07230017 & 07230018 models added September 2023) and an EPDM diaphragm. The inlet incorporates a stainless-steel strainer. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (fixed) electronically controlled tap assemblies (chrome plated brass finish). The flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator and a stainless-steel strainer on the inlet. Maximum working pressure 8.0 Bar Maximum operating temperature 70.0°C
Range of electronically controlled taps (chromium plated brass). The assemblies incorporate a touch sensitive device and are supplied with a solenoid valve to control the flow. Spout outlet incorporates a plastic aerator and the product is supplied with stainless steel strainers. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C.
Range of single hole, single outlet (fixed) electronically controlled tap assemblies (chrome plated brass). Flow is controlled by a solenoid valve activated via an infra-red sensor. Models are either cold/premixed water only or hot and cold supply with a manually adjustable temperature lever. The product incorporates stainless steel strainers and the inlets incorporate approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 70°C.
Range of single hole, single outlet (fixed) electronically controlled tap assemblies (chrome plated brass). Flow is controlled by a solenoid valve activated by via an infra-red sensor. The spout outlet incorporates a plastic aerator and the inlets incorporates stainless steel strainers. Models 351500 & 351510 incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models are either cold/premixed water only or hot and cold supply with a manually adjustable temperature lever. Maximum working pressure 8.0 bar. Maximum operating temperature 70°C.
‘Tubular’ range of wall mounted spout outlets (chromium plated brass). The flow is controlled by a solenoid valve activated via an infra-red sensor. The box assembly incorporates a solenoid valve, screwdriver operated spherical valve and the spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C.
A range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). The flow is controlled by a solenoid valve activated via an infra-red sensor. The temperature is controlled independently via a dome operating member. The spout outlet incorporates a plastic aerator. The inlets incorporate stainless steel strainers and single check valve cartridges (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection). Maximum working pressure 5.0 Bar Maximum operating temperature 65 °C
A range of wall mounted, single hole, single outlet (fixed) electronically controlled tap assembly with chromium plated brass bodies. The flow is controlled by a solenoid valve activated via an infra-red sensor and a manually adjustable temperature lever. The inlet to the solenoid incorporates a stainless-steel strainer. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 70°C.
Range of deck mounted taps for cold or premixed water with stainless steel bodies. Flow is controlled by a solenoid valve activated via an infra-red sensor, and the spout outlet incorporates a plastic aerator. Supplied with a stainless steel braided PEX lined flexible connection hose. Maximum working pressure 8.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of wall mounted, single hole, single outlet (fixed) tap assemblies (chromium plated brass) with a solenoid valve controlling the flow and activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Supplied with a stainless steel braided PEX lined flexible connecting hose. Maximum working pressure 8.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). Flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. The main body incorporates a stainless-steel strainer prior to the solenoid. Maximum working pressure 8.0 Bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of deck mounted taps for cold or premixed water (chromium plated brass). Flow is controlled by a solenoid valve activated via an infra-red sensor. The inlet hoses have stainless steel strainers and incorporate approved check valve cartridges, however, the complete products have not been fully tested to demonstrate they provide backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Range of wall mounted tap assemblies for cold or premixed water with chromium plated brass bodies. Flow is controlled by a solenoid valve activated via an infra-red sensor and the spout outlets have plastic aerators. Supplied with stainless steel braided PEX lined connection hoses. Maximum working pressure 8.0 bar.
Non-metallic materials and components comply with BS6920 at 65°C
Page 1 of 2
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.