Y. Stern Engineering (1989) Ltd Approvals


#240602028

Range of wall mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chrome plated brass bodies). Flow is controlled by a solenoid valve that is activated via an infrared sensor. The spout outlet incorporates an aerator. Maximum working pressure: 8.0 Bar. Maximum operating temperature 65°C.

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Tap(s) with a non-touch methods of flow control and a single inlet.
WRAS Approval Number:
240602028
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Stainless steel braided PEX lined flexible hose assembly incorporating ½” BSP Captive nut end connection
Marking:
Stern logo on body
Installation Requirements:
R001 R009 R040
Expiry date:
30/06/2029
Model:
280310 280300
Product Images

Approval Holder:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd. Yavne
Postcode
8122217
Phone
+972 8 9326007
General Email
leah@sternfaucets.com

View All Listings by this Company
Manufacturer:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd. Yavne
Postcode
8122217
Phone
+972 8 9326007
General Email
leah@sternfaucets.com

View All Listings by this Company

Print This Approval


#240702013

Range of wall mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (stainless steel bodies). Flow is controlled by a solenoid valve activated by via an infra-red sensor. The spout outlet incorporates a plastic aerator. Maximum working pressure - 8 Bar. Maximum operating temperature - 65 °C.

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Tap(s) with a non-touch methods of flow control and a single inlet.
WRAS Approval Number:
240702013
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
10mm spigot connection
Marking:
Stern logo on tap body
Installation Requirements:
R001 R040
Expiry date:
31/07/2029
Model:
360100 – Cubica B 360200 – Cubica E 360110 – Cubica DP B 360210 – Cubica DP E
Product Images

Approval Holder:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd. Yavne
Postcode
8122217
Phone
+972 8 9326007
General Email
leah@sternfaucets.com

View All Listings by this Company

Print This Approval


#240902025

Range of wall or ceiling mounted shower outlets (chromium plated brass). All models except SH5010 incorporate a flow regulator. Open outlet use only. Maximum operating temperature 65 °C.

Section:
1650 Shower Outlets
Section Subtitle:
Shower head(s) and/or shower handset(s).
WRAS Approval Number:
240902025
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
600100 - SH 3000 - 1/2” BSP (M) 600610 - SH 5010 - ⌀13 600400 - SH 9000 - 1/2” BSP (M) 600420 - SH 9020 - ⌀15
Marking:
Stern on body
Installation Requirements:
R001 R040
Expiry date:
30/09/2029
Model:
See Sizes
Product Images

Approval Holder:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd. Yavne
Postcode
8122217
Phone
+972 8 9326007
General Email
leah@sternfaucets.com

View All Listings by this Company

Print This Approval


#240902026

Range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). Flow is controlled with a solenoid valve activated via touch operation. The spout outlets incorporate plastic aerators and the flexible hoses incorporate a stainless-steel strainer. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Tap(s) with a non-touch methods of flow control and a single inlet.
WRAS Approval Number:
240902026
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Stainless steel braided PEX lined flexible hose assemblies with a 3/8" BSP captive nut end connector.
Marking:
Stern on top of body
Installation Requirements:
R001 R009 R006
Expiry date:
30/09/2029
Model:
Green Time AB1953 (one inlet, internal battery powered) Green Time B AB1953 (one inlet, battery powered) Green Time E AB1953 (on inlet, transformer powered)
Product Images

Approval Holder:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd. Yavne
Postcode
8122217
Phone
+972 8 9326007
General Email
leah@sternfaucets.com

View All Listings by this Company

Print This Approval


#240902027

Range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). Flow is controlled with a solenoid valve activated via touch operation. Temperature is controlled using a manual single lever operating member. The spout outlets incorporate plastic aerators. The inlets incorporate an approved check valve cartridge; however the complete assemblies have not been fully tested to demonstrate they provide backflow protection, and a stainless steel strainer. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C.

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Tap(s) with a non-touch methods of flow control and a single inlet.
WRAS Approval Number:
240902027
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Stainless steel braided PEX lined flexible hose assemblies with a 3/8" BSP captive nut end connector.
Marking:
Stern on body
Installation Requirements:
R001 R006 R010
Expiry date:
30/09/2029
Model:
Green Time 1000B AB1953 (two inlets, battery powered) Green Time 1000E AB1953 (two inlets, transformer powered) Green Time 1000 AB1953 (two inlets, transformer powered)

Approval Holder:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd. Yavne
Postcode
8122217
Phone
+972 8 9326007
General Email
leah@sternfaucets.com

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 9 of 10

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.