Y. Stern Engineering (1989) Ltd Approvals


#2210011

Range of single hole, single outlet (fixed) electronically controlled tap assemblies (chrome plated brass). Flow is controlled by a solenoid valve activated via an infra-red sensor. Models are either cold/premixed water only or hot and cold supply with a manually adjustable temperature lever. The product incorporates stainless steel strainers and the inlets incorporate approved check valve cartridges; however, the complete product has not been fully tested to demonstrate it provides backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 70°C.

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
2210011
Expiry date:
31/10/2027
Size:
Stainless-steel braided PEX lined flexible hose assemblies with 3/8" BSP (F) captive nut end connections.
Marking:
Stern logo on end of tap body
Installation Requirements:
R001 R006 R009 R010
Model:
225901 Green AB1953 – Cold or premixed water 225951 Green B AB1953 – Cold or premixed water 225941 Green E AB1953 – Cold or premixed water 225801 Green 1000 AB1953 – Hot and cold water 225871 Green 1000B AB1953 – Hot and cold water 225821 Green 1000E AB1953 – Hot and cold water
Factor:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd 8122217 Yavne ISRAEL

View All Listings by this Company

Print This Approval


#2210016

Range of single hole, single outlet (fixed) electronically controlled tap assemblies (chrome plated brass). Flow is controlled by a solenoid valve activated by via an infra-red sensor. The spout outlet incorporates a plastic aerator and the inlets incorporates stainless steel strainers. Models 351500 & 351510 incorporate an approved check valve cartridge; however, the complete product has not been fully tested to demonstrate it provides backflow protection. Models are either cold/premixed water only or hot and cold supply with a manually adjustable temperature lever. Maximum working pressure 8.0 bar. Maximum operating temperature 70°C.

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
2210016
Expiry date:
31/10/2027
Size:
Stainless steel braided flexible hose assemblies incorporating polyethylene liners and 3/8" BSP (F) captive nuts
Marking:
Stern of front base of tap body.
Installation Requirements:
R001 R006 R009 R010
Model:
351020 QUADRAT DM B 351010 QUADRAT DM E 351500 QUADRAT 1000 DMB 351510 QUADRAT 1000 DME
Factor:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd 8122217 Yavne ISRAEL

View All Listings by this Company

Print This Approval


#2210017

‘Tubular’ range of wall mounted spout outlets (chromium plated brass). The flow is controlled by a solenoid valve activated via an infra-red sensor. The box assembly incorporates a solenoid valve, screwdriver operated spherical valve and the spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 65°C.

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
2210017
Expiry date:
31/10/2027
Size:
½” BSP (M)
Marking:
Stern on front face of spout.
Installation Requirements:
R001 R040
Model:
Tubular 2030B (model code 350300). Tubular 2030E (model code 350400). Tubular 2030 LB (model code 350310). Tubular 2030 LE (model code 350410).
Factor:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd 8122217 Yavne ISRAEL

View All Listings by this Company

Print This Approval


#2210026

A range of deck mounted, single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). The flow is controlled by a solenoid valve activated via an infra-red sensor. The temperature is controlled independently via a dome operating member. The spout outlet incorporates a plastic aerator. The inlets incorporate stainless steel strainers and single check valve cartridges (however, the complete assembly has not been fully tested to demonstrate that it provides adequate backflow protection). Maximum working pressure 5.0 Bar Maximum operating temperature 65 °C

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
2210026
Expiry date:
31/10/2027
Size:
Stainless steel braided PEX lined flexible hose assemblies with 3/8" BSP captive nut end connections.
Marking:
Stern base of tap
Installation Requirements:
R001 R006 R009 R010
Model:
236930 Trendy TB 236935 Trendy TE
Factor:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd 8122217 Yavne ISRAEL

View All Listings by this Company

Print This Approval


#2210028

A range of wall mounted, single hole, single outlet (fixed) electronically controlled tap assembly with chromium plated brass bodies. The flow is controlled by a solenoid valve activated via an infra-red sensor and a manually adjustable temperature lever. The inlet to the solenoid incorporates a stainless-steel strainer. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar. Maximum operating temperature 70°C.

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
2210028
Expiry date:
31/10/2027
Size:
Stainless steel braided polyethylene lined flexible hose assembly incorporating ½” BSP male which connects to a solenoid with a 10mm spigot end connection.
Marking:
Stern on spout
Installation Requirements:
R001 R009 R010 R040
Model:
350805 tubular 1000B AB1953 350855 tubular 1000E AB1953 350815 tubular 1000LB AB1953 350865 tubular 1000LE AB1953
Manufacturer:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd 8122217 Yavne ISRAEL

View All Listings by this Company

Print This Approval


#2212004

Range of deck mounted taps for cold or premixed water with stainless steel bodies. Flow is controlled by a solenoid valve activated via an infra-red sensor, and the spout outlet incorporates a plastic aerator. Supplied with a stainless steel braided PEX lined flexible connection hose. Maximum working pressure 8.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
2212004
Expiry date:
31/12/2027
Size:
Solenoid with 10mm spigot.
Marking:
Stern on top of tap body.
Installation Requirements:
R001 R006 R007
Model:
239003 – Trendy B AISI316, 239103 – Trendy E AISI316, 239404 – Trendy LB AISI316, 239403 – Trendy LE AISI316, 235104 – Smart B AISI316, 235204 – Smart E AISI316, 235113 – Smart LB AISI316, 235213 – Smart LE AISI316.
Factor:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd 8122217 Yavne ISRAEL

View All Listings by this Company

Print This Approval


#2212008

Range of wall mounted, single hole, single outlet (fixed) tap assemblies (chromium plated brass) with a solenoid valve controlling the flow and activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. Supplied with a stainless steel braided PEX lined flexible connecting hose. Maximum working pressure 8.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
2212008
Expiry date:
31/12/2027
Size:
½” BSP (M).
Marking:
Stern on spout body.
Installation Requirements:
R001 R007 R040
Model:
351110 - Quadrat B AB 1953, 351210 - Quadrat E AB 1953, 351115 - Quadrat LB AB 1953, 351215 - Quadrat LE AB 1953.
Factor:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd 8122217 Yavne ISRAEL

View All Listings by this Company

Print This Approval


#2212022

Range of single hole, single outlet (fixed) electronically controlled tap assemblies (chromium plated brass). Flow is controlled by a solenoid valve activated via an infra-red sensor. The spout outlet incorporates a plastic aerator. The main body incorporates a stainless-steel strainer prior to the solenoid. Maximum working pressure 8.0 Bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
2212022
Expiry date:
31/12/2027
Size:
Stainless steel braided PEX lined flexible hose assemblies with 3/8” BSP captive nut end connections.
Marking:
Stern on operating member.
Installation Requirements:
R001 R006 R009
Model:
237250 Extreme Plus B, 237300 Extreme E, 237200 Extreme B, 237350 Extreme Plus E.
Factor:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd 8122217 Yavne ISRAEL

View All Listings by this Company

Print This Approval


#2212024

Range of deck mounted taps for cold or premixed water (chromium plated brass). Flow is controlled by a solenoid valve activated via an infra-red sensor. The inlet hoses have stainless steel strainers and incorporate approved check valve cartridges, however, the complete products have not been fully tested to demonstrate they provide backflow protection. The spout outlet incorporates a plastic aerator. Maximum working pressure 8.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
2212024
Expiry date:
31/12/2027
Size:
Stainless steel braided PEX lined flexible hose assemblies with 3/8” BSP captive nut end connections.
Marking:
STERN on body.
Installation Requirements:
R001 R006 R009
Model:
239050 – Trendy Plus B, 239160 – Trendy Plus LE, 239051 – Trendy Plus B AB1953, 239161 – Trendy Plus LE AB1953.
Factor:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd 8122217 Yavne ISRAEL

View All Listings by this Company

Print This Approval


#2212034

Range of wall mounted tap assemblies for cold or premixed water with chromium plated brass bodies. Flow is controlled by a solenoid valve activated via an infra-red sensor and the spout outlets have plastic aerators. Supplied with stainless steel braided PEX lined connection hoses. Maximum working pressure 8.0 bar.

Non-metallic materials and components comply with BS6920 at 65°C

Section:
0684 Combination Tap Assemblies
Section Subtitle:
Non-touch Methods of Control Products listed in this section utilise flow control methods that do not require touch to activate.
WRAS Approval Number:
2212034
Expiry date:
31/12/2027
Size:
10mm spigot.
Marking:
Stern logo on sensor plate.
Installation Requirements:
R001 R007 R040
Model:
340300 – Extreme WMB, 340200 – Extreme WME, 340400 – Extreme WM LB, 340500 – Extreme WM LE.
Factor:
Y. Stern Engineering (1989) Ltd
Company Name
Y. Stern Engineering (1989) Ltd
Address
15 Gan Rave Blvd 8122217 Yavne ISRAEL

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2 of 4

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.