Range of wall mounted combination boilers providing domestic hot water via a plate heat exchanger and pressurised central heating system.
The primary circuit incorporates a pressure relief valve set at 3.0 bar and an expansion vessel. The products are supplied with isolation valve on both the DHW and CH circuits. The secondary circuit (DHW) incorporates a plastic flow restrictor and stainless-steel strainer.
Some models (see model section) are supplied with a filling loop assembly consisting of an in-line isolation valve, an in-line double check valve assembly which incorporates an isolation valve.
Maximum working pressures:
DHW: 10.0 Bar
CH: 2.5 Bar
Maximum operating temperature:
DHW: 65.0°C
CH: 85.0°C
- Section:
- 1465 Heaters
- Section Subtitle:
- Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
- WRAS Approval Number:
- 240502715
- Basis of Compliance:
- Tested to regulators Specification Test Code Sheets
- Size:
- DHW: 15mm compression.
CH: 22mm compression
- Marking:
- Range name on front cover, Model, Max pressure, Max temperature and product information on data plate on body
- Installation Requirements:
- R001 R140 R360
- Expiry date:
- 31/05/2029
- Model:
-
Models without a filing loop supplied:
0010016113 - Glow-worm ESSENTIAL 24c -A (H-GB)
0010016115 - Glow-worm ESSENTIAL 28c -A (H-GB)
0010016127 - Heatline CAPRIZ 2 24c -A (H-GB)
0010016128 - Heatline MONZA 2 24c -A (H-GB)
0010016129 - Heatline CAPRIZ 2 28c -A (H-GB)
0010016130 - Heatline MONZA 2 28c -A (H-GB)
0010021401 - Glow-worm EASICOM 3 24c -A (H-GB)
0010021402 - Glow-worm EASICOM 3 28c -A (H-GB)
0010020392 - Vaillant VUW 256/6-3 (H-GB) ecoFIT sustain 825
0010020393 - Vaillant VUW 306/6-3 (H-GB) ecoFIT sustain 830
0010020394 - Vaillant VUW 356/6-3 (H-GB) ecoFITsustain 835
Models with a filling loop supplied:
0010020389 - Vaillant VUW 256/6-3 (H-GB) ecoFIT pure 825
0010020390 - Vaillant VUW 306/6-3 (H-GB) ecoFIT pure 830
0010020391 - Vaillant VUW 356/6-3 (H-GB) ecoFIT pure 835
0010019813 - Vaillant VUW 306/6-3 (P-GB) ecoFIT pure 830 P
0010021204 - Glow-worm BETACOM 4 24c -A (H-GB)
0010021205 - Glow-worm BETACOM 4 30c -A (H-GB)
0010021404 - Glow-worm ULTIMATE 3 30c -A (H-GB)
0010021405 - Glow-worm ULTIMATE 3 35c -A (H-GB)
0010027591 - Glow-worm ENERGY 2 30c -A (P-GB)
0010035896 - Glow-worm ENERGY 7 25c (H-GB)
0010035897 - Glow-worm ENERGY 7 30c (H-GB)
0010035898 - Glow-worm ENERGY 7 35c (H-GB)
Product Images
- Approval Holder:
- Vaillant GmbH
Company Name
Vaillant GmbH
Address
Berghauser Strasse, 40
D-42859 Remscheid
Phone
Tel: +49 2191 182126
View All Listings by this Company