Lochinvar Ltd. Approvals


#2111371

Range of floor standing gas fired combination boilers providing domestic hot water via a stainless-steel plate heat exchanger. Unit is supplied with a safety relief valve (8.0 bar). Maximum working pressure 7.5 bar. Maximum operating temperature 85°C.

Section:
1465 Heaters
Section Subtitle:
Combination boilers and Water Jacketed Tube heaters. Low volume water content. Heat retained in water heaters will cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to accommodate excess pressure within the system. Particular care is required where check valves are positioned, or loose jumper valves are thought to be upstream of the heater.
WRAS Approval Number:
2111371
Size:
2 ½” BSP (M)
Marking:
Lochinvar on front casing. Lochinvar , model & serial number on adhesive label on body
Installation Requirements:
R001 R140 R360
Expiry date:
30/11/2026
Model:
TTW410 & TTW580 FLOOR STANDING GAS FIRED COMBINATION BOILERS

Approval Holder:
Lochinvar Ltd.
Company Name
Lochinvar Ltd.
Address
8 Lombard Way The MXL Centre Banbury
Postcode
OX16 4TJ
Phone
+44 (0) 1295 269981
General Email
general@lochinvar.ltd.uk

View All Listings by this Company

Print This Approval


#240504725

Range of direct gas fired condensing water heaters with a stainless steel body. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.

Section:
1400 Heaters
Section Subtitle:
Gas fired, closed outlet. Heat retained in water heaters may cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to prevent excess pressure within the system.
WRAS Approval Number:
240504725
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
¾” BSP (F)
Marking:
Lochinvar on body.
Installation Requirements:
R001 R140
Expiry date:
31/05/2029
Model:
LGSS 200-600 LGSS 200-780 WATER HEATERS

Approval Holder:
Lochinvar Ltd.
Company Name
Lochinvar Ltd.
Address
8 Lombard Way The MXL Centre Banbury
Postcode
OX16 4TJ
Phone
+44 (0) 1295 269981
General Email
general@lochinvar.ltd.uk

View All Listings by this Company

Print This Approval


#240504721

Range of direct fired water heaters with an enamel lining and a titanium anode. Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.

Section:
1400 Heaters
Section Subtitle:
Gas fired, closed outlet. Heat retained in water heaters may cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to prevent excess pressure within the system.
WRAS Approval Number:
240504721
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
Please refer to model.
Marking:
Lochinvar on body.
Installation Requirements:
R001 R140
Expiry date:
31/05/2029
Model:
LGC 160-210 CE LGC 200-210 CE LGC 160-350 CE LGC 200-350 CE LGC 245-420 CE LGC 285-420 CE LGC 245-560 CE LGC 285-560 CE LGC 380-560 CE WATER HEATERS

Approval Holder:
Lochinvar Ltd.
Company Name
Lochinvar Ltd.
Address
8 Lombard Way The MXL Centre Banbury
Postcode
OX16 4TJ
Phone
+44 (0) 1295 269981
General Email
general@lochinvar.ltd.uk

View All Listings by this Company

Print This Approval


#240504726

Range of stainless steel lined direct water heaters fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 8.0 bar. Maximum operating temperature 85°C.

Section:
1400 Heaters
Section Subtitle:
Gas fired, closed outlet. Heat retained in water heaters may cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to prevent excess pressure within the system.
WRAS Approval Number:
240504726
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
1½” BSP (M)
Marking:
Lochinvar on adhesive label on body.
Installation Requirements:
R001 R140
Expiry date:
31/05/2029
Model:
SIVS 66 G E SIVS 100 G E SIVS 110 G E SIVS 130 G E SIVS 165 G E SIVS 220 G E SIVT 66 G E SIVT 100 G E SIVT 110 G E SIVT 130 G E SIVT 165 G E SIVT 220 G E LST 66 G E LSTR 66 G E LST 100 G E LSTR 100 G E LST 110 G E LSTR 110 G E LST 130 G E LSTR 130 G E LST 165 G E LSTR 165 G E LSTR 220 G E LST 220 G E

Approval Holder:
Lochinvar Ltd.
Company Name
Lochinvar Ltd.
Address
8 Lombard Way The MXL Centre Banbury
Postcode
OX16 4TJ
Phone
+44 (0) 1295 269981
General Email
general@lochinvar.ltd.uk

View All Listings by this Company

Print This Approval


#240504724

Range of indirect water heaters with an enamel lining, a magnesium sacrificial anode and single wall spiral heat exchanger (maximum working pressure 6.0 bar). Fitted with a temperature and pressure relief valve set at 10.0 bar & 95°C. Maximum working pressure 7.0 bar. Maximum operating temperature 80°C

Section:
1400 Heaters
Section Subtitle:
Gas fired, closed outlet. Heat retained in water heaters may cause expansion of water after closure of draw-off taps and valves. Provision for expansion of water must be made to prevent excess pressure within the system.
WRAS Approval Number:
240504724
Basis of Compliance:
Tested to regulators Specification Test Code Sheets
Size:
¾” BSP (F)
Marking:
Lochinvar on adhesive label on body.
Installation Requirements:
R001 R140
Expiry date:
31/05/2029
Model:
SIVS 330 G E SIVS 440 G E SIVS 550 G E SIVS 660 G E LST 330 G E LST 440 G E LST 550 G E LST 660 G E

Approval Holder:
Lochinvar Ltd.
Company Name
Lochinvar Ltd.
Address
8 Lombard Way The MXL Centre Banbury
Postcode
OX16 4TJ
Phone
+44 (0) 1295 269981
General Email
general@lochinvar.ltd.uk

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 1 of 2

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.