Taps

Section Code 1780 : Hose union, metal. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.

Back To Directory Sections

#2201348

Range of wall mounted hose union taps incorporating a brass body with a non-rising spindle headwork and a T type operating member. The JMYG-064 1/2” model incorporates two approved single check valve cartridges (one on the inlet, one on the outlet), however the complete product has not been fully tested to demonstrate it provides backflow protection. Product incorporates a drain plug after the inlet check valve cartridge. Maximum working pressure 10.0 bar. Maximum operating temperature 80°C.

Section:
1780 Taps
Section Subtitle:
Hose union, metal. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2201348
Expiry date:
31/01/2027
Size:
see model
Marking:
JMING, size, WRAS and EN1213 on body.
Installation Requirements:
R001 R040
Model:
JMYG-062 - ½” BSP (M), JMYG-063 - ¾” BSP (M), JMYG-064 - ½” BSP (M).
Factor:
Ningbo Jiaming Metal Products Co. Ltd.
Company Name
Ningbo Jiaming Metal Products Co. Ltd.
Address
No.158 JinCi Road Hangzhou Wan New Zone Cixi City
Country
Zhejiang
Phone
+86-574-63575000

View All Listings by this Company

Print This Approval


#2204309

Range of wall mounted hose union taps with brass bodies, incorporating a rising spindle headwork with a ‘T’ type operating member. BC01L & BC01LA models are lockshield type. The BC01A & BC01LA models incorporate an approved check valve cartridge on the inlet and outlet however, the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 16.0 bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union, metal. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2204309
Expiry date:
30/04/2027
Size:
½” BSP(M) & ¾” BSP(M)
Marking:
Hongxing on body.
Installation Requirements:
R001 R040
Model:
BC01, BC01L, BC01A, BC01LA
Factor:
Hongxing Manufacturing Group Ltd
Company Name
Hongxing Manufacturing Group Ltd
Address
Yanye, Qinggang, Yuhuan, Zhejiang
Country
China
Phone
0086-576-87118156
General Email
sales@hongxingmfg.com

View All Listings by this Company

Print This Approval


#2201086

Range of wall mounted hose union taps (brass body or DZR brass body - see model) incorporating a non-rising spindle headwork with a ‘T’-type operating member. Maximum working pressure 14.0 Bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union, metal. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2201086
Expiry date:
31/01/2027
Size:
½” BSP (M).
Marking:
MF, Masterflow -A- Logo, size, CR, WRAS, BS1010-2 & BS6282 on body.
Installation Requirements:
R001 R040
Model:
MBHU04 & MBHU04DCV HOSE UNION TAPS
Factor:
Masterflow Products Limited
Company Name
Masterflow Products Limited
Address
70-76 Greatbridge Water Street Manchester Lancashire
Postcode
M1 5ES

View All Listings by this Company

Print This Approval


#1912084

Range of wall mounted hose union taps (various body materials) incorporating a non-rising spindle headwork with a butterfly handle operating member. The spout outlets incorporate a hose union connector. Maximum working pressure 16.0 Bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union, metal. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
1912084
Expiry date:
31/12/2024
Size:
½” BSP (M)
Marking:
CPS, Date of manufacture MM/YY and size on body.
Installation Requirements:
R001 R040
Model:
960981
Factor:
CITY PLUMBING SUPPLIES HOLDINGS LTD
Company Name
CITY PLUMBING SUPPLIES HOLDINGS LTD
Address
HIGHBOURNE GROUP LTD HIGHBOURNE HOUSE ELDON WAY NORTHHAMPTONSHIRE
Postcode
NN6 7SL

View All Listings by this Company

Print This Approval


#2201101

Range of wall mounted hose union taps (brass body or DZR brass body - see model) incorporating a non-rising spindle headwork with a ‘T’-type operating member. The CMBHUBDC-D model incorporate two approved single check valve cartridges, however the complete product has not been fully tested to demonstrate it provides backflow protection. Maximum working pressure 14.0 Bar. Maximum operating temperature 85°C.

Section:
1780 Taps
Section Subtitle:
Hose union, metal. a. All cold water fittings located outside the thermal envelope, or those outside the building should be protected against damage by freezing. b. A servicing valve shall be fitted to the supply pipe to this fitting and shall be located within the thermal envelope of the building. Where in existing house installations a hosepipe is to be used from an existing hose union tap located outside a house and which is not provided with backflow protection, either: a. The existing hose union tap should be provided with a double check valve (Type EC or ED) located inside the building; or b. The tap should be replaced with a hose union tap that incorporates a double check valve (type HUK1); or c. A hose union backflow prevention (Type HA) or a double check valve should be continuously fitted to the outlet of the tap; or d. Is legally installed in any premises.
WRAS Approval Number:
2201101
Expiry date:
31/01/2027
Size:
½” BSP (M).
Marking:
CMBFHUB-D Model MID and size on body. CMBHUBDC-D, CR and size on body.
Installation Requirements:
R001 R040
Model:
Brass body: CMBFHUB-D DZR brass body: CMBHUBDC-D
Factor:
Navigator MSL Ltd.
Company Name
Navigator MSL Ltd.
Address
Mill Road, Sharnbrook, Beds.
Postcode
MK44 1NP
Phone
01234 781234

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 3 of 4

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.