Section Code 5030 : Factory applied pipe & fittings coatings.
Back To Directory Sections'Pipeclad 704G'. Factory applied, green coloured epoxy coating. Apply as per manufacturer's product information dated 'August 16,2022'. Cure for 12 minutes@232°C. For use with water up to 85°C. This material is only approved for the curing conditions that appear on the approval. If the curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘ET Ordinary Portland Cement’. Factory applied, grey coloured cement. Mix and apply as per manufacturer’s ‘Standard Operating Procedure 'ET-SAM/DIP-PP/SOP/013', 'Rev. No 01', dated '15.12.2019'. Cure for 40 days@26°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘ET Sulphate Resisting Cement’. Factory applied, grey coloured cement. Mix and apply as per manufacturer’s ‘Standard Operating Procedure 'ET-SAM/DIP-PP/SOP/014', 'Rev. No 01', dated '15.12.2019'. Cure for 40 days@26°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘ET Blast Furnace Slag Cement’. Factory applied, grey coloured cement. Mix and apply as per manufacturer’s ‘Standard Operating Procedure 'ET-SAM/DIP-PP/SOP/012', 'Rev. No 01', dated '15.12.2019'. Cure for 40 days@26°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'RMD 7080/xx, RUD 2230/xx, RMD 7100/xx, RUD 2247/xx, RUD 2273/xx, RMD 7061/xx'. 'xx' denotes the customer and can be replaced with numbers between 01 & 99. Factory applied, blue coloured enamel coating. Apply as per manufacturer's instructions '0703231010' dated 14.03.23. Cure for 10 minutes@860°C. For use with water up to 85°C. These materials are only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
ML-9005WGL414 (black coloured - RAL 9005), ML-6018WGL424 (green coloured - RAL 6018), ML-9A10WGL444 (white coloured - RAL 9010), ML-5007WGL424 (blue coloured - RAL 5007) & ML-6621WGL424 (green coloured - Pantone 334 C). Factory applied, electro-statically sprayed epoxy powder coatings. Apply as per manufacturer’s Product Data Sheet ‘Pdb_ML-WGL414-EN (03-2023)’, dated ’23.03.2023’. Stove (cure) for 8 minutes at 180°C. For use with water up to 65°C. These materials are only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'TEPICOMPOWDER PC-200F U'. Factory applied, grey coloured epoxy resin powder coating. Apply as per manufacturer's Technical Information 'No. SG23180' dated '11 June 2021'. Cure for 10 minutes@200°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'KUBOTAPOWDER TK1413F M'. Factory applied, grey coloured epoxy resin powder coating. Apply as per manufacturer's Technical Information 'No. SG23180' dated '11 June 2021'. Cure for 10 minutes@200°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Hempadur Multi-Strength 35531 Grey'. Factory applied, grey two-component epoxy coating. Mix base and curing agent in a 3:1 volume ratio and apply in accordance with manufacturer's Product Data Sheet issued July 2022. Cure for 7 days@20°C. For use with water up to 50°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Hempadur Multi-Strength 35531 Red'. Factory applied, red two-component epoxy coating. Mix base and curing agent in a 3:1 volume ratio and apply in accordance with manufacturer's Product Data Sheet issued July 2022. Cure for 7 days@20°C. For use with water up to 50°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘EE8000 – 5006836 & EE8000-5006835'. Factory applied, blue coloured epoxy powder coatings. Apply by fusion bond dip as per Product Data Sheet 'version 5.0' dated '25/07/2024'. Cure for 7 minutes@200°C. For use with water up to 70°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘KUBOTA SEAL AC’. Factory applied, colourless acrylic resin coating. Apply as per manufacturer’s instructions ‘ref. no. 65700H-2.3’ dated 'Mar. 14.2017'. Cure for 7 days@27°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
‘V-PET#1600 Gray F’. Factory applied, dark grey coloured epoxy resin powder coating. Apply as per manufacturer’s instructions ‘ref.no. VP1600-PD-170412’, dated '12th April 2017'. Cure for 10 minutes@200°C. For use with water up to 60°C. This material is only approved for the curing conditions that appear on the approval. If the curing conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'5013 High chlorinated polyethylene anticorrosive coating'. Factory applied, blue coloured polyethylene coating. Apply as per manufacturer's TDS/IFU number '001', dated '2022.11.30'. Cure for 24 hours@23°C. For use with water up to 65°C. This material is only approved for the curing conditions that appear on the approval. If the cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Factory applied, grey coloured blast furnace slag cements. ‘BFSC PAM MDN 1’. Mix water, sand, admixture & cement in a mass ratio of 0.33:2.35:0.0080:1 and apply as per manufacturer’s instructions ‘CE 7M’, dated ‘25/08/15’. Cure for 7 hours@70°C. For use with water up to 60°C. BFSC PAM GDN 1’. Mix water, sand, admixture & cement in a mass ratio of 0.33:2.84:0.0065:1 and apply as per manufacturer’s instructions ‘CE 8M/-3A’, dated ‘25/08/15’. Cure for 7 hours@70°C. For use with water up to 60°C. These materials are only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'GCF-SRC'. Factory applied, grey coloured cement mortar. Mix sand, cement and water in a ratio of 4:2:1 and apply as per manufacturer's instructions 'QC-WI-8.1.8, revision 2/0, issue date 30/10/2021'. Cure for 28 days@24°C. For use with water up to 65°C. This material is only approved for the mixing & curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Titanseal 989'. Site applied, two-component, grey coloured (once mixed) polyurethane coating. Mix the grey coloured (opaque) base coating with the amber coloured hardener in a 3:1 volume ratio and apply Coat 1 as per manufacturer's application instructions dated '09.03.2018'. Cure for 4 hours@7°C. Mix and apply Coat 2 using the same mix ratio and application instructions and then cure for 14 days@7°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mixing and/or curing conditions are varied from those specified on the approval then the materials are not covered by the scope of the approval.
'Epilux QD DW Coating - Blue'. Factory applied, blue coloured, two-component epoxy coating. Mix Base and Catalyst in a 3:1 volume ratio and apply as per manufacturer's 'Product Information Data Sheet No: 780', 'Revision: 00', 'Issue Date Feb-22'. Cure for 7 days@30°C. For use with water up to 60°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Epoxy PB Pipe Green (W) & Epoxy FB Pipe Green (HW)'. Factory applied, green coloured epoxy powder coatings. The substrate to which the coating is to be applied is pre-heated to 220˚C for 15 minutes before applying the coating as per product data sheet dated '27th June 2023'. Post-cure for 15 minutes@215°C. For use with water up to 85°C. This material is only approved for the pre-heat and post-cure conditions that appear on the approval. If the pre-heat and/or post-cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
'Versapox PW'. Factory applied, grey coloured, two component solvent free epoxy coating. Mix base and curing agent in a 3:1 volume ratio and apply as per manufacturer's product data sheet 'issue No. 01', dated 'Jan 2022'. Cure for 10 days@20°C. For use with water up to 23°C. This material is only approved for the mixing and curing conditions that appear on the approval. If the mix and/or cure conditions are varied from those specified on the approval then the material is not covered by the scope of the approval.
Page 14 of 26
We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.