Heat Exchangers

Section Code 1350 :

Back To Directory Sections

#2101035

Range of stainless-steel heat exchangers. Maximum working pressure of primary Circuit 3.0 bar. Maximum working pressure of secondary Circuit 10.0 bar. Maximum operating temperature 80˚C

Section:
1350 Heat Exchangers
Size:
Primary Circuit ¾” captive nut x ¾” BSP (M) Sanitary Circuit 21mm (OD) Spigot Fitting x ½” BSP (M)
Marking:
Condevo SpA, serial number and date of manufacture (DD/MM/YY) on adhesive label on body.
Installation Requirements:
R001
Expiry date:
31/01/2026
Model:
Type E 12439 PP11CE6V02, PP21CE6V02 & PP33CE6V02. Type E 12440 PP10CE6H02, PP22CE6H02 & PP34CE6H02.
Product Images

Approval Holder:
Condevo SpA
Company Name
Condevo SpA
Address
Via Luna, Z.A. 26866 Marudo (LO) Italy

View All Listings by this Company
Manufacturer:
Condevo SpA
Company Name
Condevo SpA
Address
Via Luna, Z.A. 26866 Marudo (LO) Italy

View All Listings by this Company

Print This Approval


#2012353

Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.

Section:
1350 Heat Exchangers
Size:
¾” BSP (M)
Marking:
Inta logo, address, serial number, technical & pressure information on label inside case.
Installation Requirements:
R001
Expiry date:
31/12/2025
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
HIPER2TPSZ80 HIPER2SPSW80 HIPER2SPSW80IS HIPER2SPSW80ZE
Product Images

Approval Holder:
Intatec Limited
Company Name
Intatec Limited
Address
Airfield Industrial Estate Hixon Staffordshire
Postcode
ST18 0PF
Country
United Kingdom
Phone
01889272180
General Email
ryan.tilsley@intatec.co.uk

View All Listings by this Company

Print This Approval


#2010078

Range of RINNAI continuous flow water heaters with stainless steel plate heat exchangers providing heating and instantaneous hot water .The hot water is generated via a plate heat exchanger. Also supplied is a drain valve and a flow sensing device. Maximum working pressure - 10 bar Maximum working pressure - 85˚C

Section:
1350 Heat Exchangers
Size:
¾” Male inlet and outlet
Marking:
RINNAI on body and data badge including date of manufacture (YY/MM)
Installation Requirements:
R001
Expiry date:
31/10/2025
Model:
REU-N3237FFC-E – N1600i (57.9kW / 29Kg) REU-N3237WC-E – N1600e (57.9kW / 29Kg) REU-N2635FFC-E – N1300i (47kW / 28Kg) REU-N2635WC-E – N1300e (47kW / 28Kg)
Product Images

Approval Holder:
Rinnai UK Ltd
Company Name
Rinnai UK Ltd
Address
9 Christleton Court Manor Park Runcom
Postcode
WA7 18T
Phone
01928 531 870
General Email
info@rinnaiuk.com

View All Listings by this Company
Manufacturer:
Rinnai UK Ltd
Company Name
Rinnai UK Ltd
Address
9 Christleton Court Manor Park Runcom
Postcode
WA7 18T
Phone
01928 531 870
General Email
info@rinnaiuk.com

View All Listings by this Company

Print This Approval


#2012362

Shower waste water heat recovery unit, consisting of a PVC-U waste pipe with an internal copper tube which provides a double wall separation between the waste water and cold mains supply. Maximum working pressure 10.0 bar. Maximum operating temperature 30°C.

Section:
1350 Heat Exchangers
Size:
½” BSP (F).
Marking:
Recoup logo, pipe ID outside wall, PVC-U 63x2.0, 16028740 kiwa, 5 16-01-19 11.40, PVC MET HERGERBUIKGRANTIE on adhesive label on outside wall.
Installation Requirements:
R001 R008
Expiry date:
31/12/2025
Model:
Recoup Pipe HEX: R-PHX-01 (2.1m length). Recoup Pipe HEX-Rd: R-PHX-03 (1.7m length).

Approval Holder:
Recoup Energy Solutions Ltd.
Company Name
Recoup Energy Solutions Ltd.
Address
Trumpeter House Trumpeter Rise Long Stratton
Postcode
NR15 2DY
Country
United Kingdom
Phone
+441379844010
General Email
ian@recoup.co.uk

View All Listings by this Company

Print This Approval


#2012365

Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.

Section:
1350 Heat Exchangers
Size:
¾” BSP (M)
Marking:
BAXI ON FRONT OF CASING. BAXI, address, serial number, technical & pressure information on label inside case.
Installation Requirements:
R001
Expiry date:
31/12/2025
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
BAXI ASSURE HIMAX TWIN ID 90/30 ELECTRONICALLY CONTROLLED HEAT INTERFACE UNITS

Approval Holder:
Baxi Heating UK Limited
Company Name
Baxi Heating UK Limited
Address
Brooks House, Coventry Road, Warwick
Postcode
CV34 3LL

View All Listings by this Company

Print This Approval


#2012088

Range of waste water heat recovery systems incorporating a twin wall copper coil (7773414 models) or stainless steel (7771332 models). Maximum working pressure 10.0 bar. Cold water use only.

Section:
1350 Heat Exchangers
Size:
½” BSP (M) (7773414) or ¾” BSP (F) (7771332)
Marking:
BAXI, Model, and technical info on adhesive label located on plastic casing.
Installation Requirements:
R001
Expiry date:
31/12/2025
Model:
VERTICAL SHRU 7771332 & HORIZONTAL SHRU 7773414 HEAT EXCHANGERS

Approval Holder:
Baxi Heating UK Ltd.
Company Name
Baxi Heating UK Ltd.
Address
Club Street Bamber Bridge Preston Lancaster
Postcode
PR5 6FN

View All Listings by this Company

Print This Approval


#2012366

Electronically controlled heat interface units (HIU) with twin stainless-steel plate heat exchangers providing space heating and instantaneous hot water. The cold inlet supply to the plate heat exchanger incorporates an isolation valve and a water hammer arrestor. The space heating circuit incorporates an expansion vessel and a pressure relief valve (set at 3.0 bar). The product is supplied with a filling loop assembly consisting of an elbow shaped copper pipe, isolation valve and double check valve assembly (suitable for backflow protection against fluid category 3) which incorporates an isolation valve. The cold mains inlet and the domestic hot water outlet each incorporate a brass bodied spherical valve with a butterfly handle. Maximum working pressures and operating temperatures: Primary: 16.0 bar and 90˚C. Domestic hot water (DHW): 10 bar and 65˚C. Secondary (space heating): 2.5 bar and 85˚C.

Section:
1350 Heat Exchangers
Size:
¾” BSP (M)
Marking:
RBM, address, serial number, technical & pressure information on label inside case.
Installation Requirements:
R001
Expiry date:
31/12/2025
Proviso:
Supplied with a temporary filling loop. The filling loop must be installed with the appropriate backflow prevention device in accordance with clause G24.2, Guidance to the Water Supply (Water Fittings) Regulations 1999.
Model:
37370000 ELECTRONICALLY CONTROLLED HEAT INTERFACE UNITS
Product Images

Approval Holder:
RBM S.p.a.
Company Name
RBM S.p.a.
Address
Componenti Per Impianti Idrotermici Via S. Giuseppe, 1 25075 Nave (Brescia)
Country
Italy

View All Listings by this Company

Print This Approval


#2105309

Copper heat transformer. Maximum working pressure 11.0 bar. Maximum operating temperature 95°C.

Section:
1350 Heat Exchangers
Size:
76mm copper tube
Marking:
Company name and address, model, operating parameters, size & date of manufacture (MM/YYYY) on body.
Installation Requirements:
R001
Expiry date:
31/05/2026
Model:
Heat Transformer 60
Product Images

Approval Holder:
Copper Industries Ltd
Company Name
Copper Industries Ltd
Address
Toome Business Park 21 Hillhead Road Toome Co Antrim
Postcode
BT41 3SF
Country
United Kingdom
Phone
02879 659736
General Email
mail@copperindustries.co.uk

View All Listings by this Company
Manufacturer:
Copper Industries Ltd
Company Name
Copper Industries Ltd
Address
Toome Business Park 21 Hillhead Road Toome Co Antrim
Postcode
BT41 3SF
Country
United Kingdom
Phone
02879 659736
General Email
mail@copperindustries.co.uk

View All Listings by this Company

Print This Approval


#2105044

Range of domestic hot water units incorporating instantaneous or semi-instantaneous plate heat exchanger assemblies. The product incorporates a motorised control valve, managed primary and secondary pumps (see model), and a drain valve on both circuits. Maximum working pressures: 10.0 bar primary, 9.5 bar secondary. Maximum operating temperatures: 110°C primary, 85°C secondary.

Section:
1350 Heat Exchangers
Size:
1 ¼” BSP (F) on both primary and secondary circuits.
Marking:
Cetetherm SAS, AQUAFIRST, Max working pressure/temperature for primary and secondary circuits, serial number, article number and year of manufacture (YYYY) on adhesive label on heat exchanger frame.
Installation Requirements:
R001 R140 R360
Expiry date:
31/05/2026
Model:
AQUAFIRST 2000/4000/6100/8000 series: Flxxnnyy FI = Aquafirst range xx = 20: 2000 M3 Plates serie (differentiation on primary side). 40: 4000 M3 Plates serie (differentiation on primary side). 61: 6100 M6 Plates serie (differentiation on primary side and secondary pump). 80: 8000 M6 Plates serie (differentiation on primary side and secondary pump). nn = 07 up to 55 for the number of gasketed plates. yy = IS: Instantaneous (no pump on DHW) with single primary pump ID: Instantaneous (no pump on DHW) with twin head primary pump SS: Semi-instantaneous with one primary pump and one DHW pump DS: Semi-instantaneous with twin head primary pump and one DHW pump DD: Semi-instantaneous with twin head primary pump and two DHW pump Article Number: FI2007IS. FI2007ID. FI2007SS. FI2007DS. FI2007DD. FI2017IS. FI2017ID. FI2017SS. FI2017DS. FI2017DD. FI4027IS. FI4027ID. FI4027SS. FI4027IS. FI4027DD. FI4045IS. FI4045ID. FI4045SS. FI4045DS. FI4045DD. FI6113IS. FI6113ID. FI6113SS. FI6113DS. FI6113DD. FI6123IS. FI6123ID. FI6123SS. FI6123DS. FI6123DD. FI8031IS. FI8031ID. FI8031SS. FI8031DS. FI8031DD. FI8055IS FI8055ID FI8055SS FI8055DS FI8055DD.
Product Images

Approval Holder:
CETETHERM SAS
Company Name
CETETHERM SAS
Address
Route du stade ZI du moulin Pontcharra sur Turdine
Postcode
69490
Country
France
General Email
jeanmichel.montoni@cetetherm.com

View All Listings by this Company
Manufacturer:
CETETHERM SAS
Company Name
CETETHERM SAS
Address
Route du stade ZI du moulin Pontcharra sur Turdine
Postcode
69490
Country
France
General Email
jeanmichel.montoni@cetetherm.com

View All Listings by this Company

Print This Approval


#2105021

Range of wastewater heat recovery systems incorporating a double wall stainless steel corrugated pipe. Maximum working pressure 16.0 bar. Cold water use only.

Section:
1350 Heat Exchangers
WRAS Approval Number:
2105021
Note:
Tangit upv-c solvent cement used on joints.
Size:
¾” BSP (F) inlet x outlet.
Marking:
Zypho logo, model name, serial number, WRAS and other product info on adhesive label located on body.
Installation Requirements:
R001
Expiry date:
31/05/2026
Model:
ZYPHO PiPe 55 DW. ZYPHO PiPe 60 DW. ZYPHO PiPe 65 DW.

Approval Holder:
Zypho, SA
Company Name
Zypho, SA
Country
Portugal
Phone
+351 210 991 351
General Email
b2b@zypho.pt

View All Listings by this Company
Manufacturer:
Zypho, SA
Company Name
Zypho, SA
Country
Portugal
Phone
+351 210 991 351
General Email
b2b@zypho.pt

View All Listings by this Company

Print This Approval



Back To Directory Sections

Page 2 of 5

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.