Ideal Heating Approvals


#2305339

Range of vertical cased and insulated direct and indirect unvented stainless steel hot water storage cylinders. Fitted with a Caleffi 309463 GLD temperature and pressure relief valve sat at 6 bar & 90°C, and supplied with an inlet control group consisting of in-line pressure reducing valve (Caleffi set at 3 bar) and pressure relief valve (Caleffi CWIC200055) set at 4.5 bar, and incorporates a stainless-steel mesh and an approved check valve cartridge (verified by test suitable for backflow protection against Fluid Category 2), expansion vessel and filling loop. Maximum working pressure 4.4 bar. Maximum operating temperature 99°C.

Section:
1890 Unvented Heating Apparatus
WRAS Approval Number:
2305339
Expiry date:
31/05/2028
Size:
28mm compression.
Marking:
Manufacturers name, address, date of manufacturer, capacity, model no, serial no, pressure and technical information.
Installation Requirements:
R001 R140 R360 R511 R530
Model:
IDEPLUHP150PPSZ & IDEPLUHP180PPSZ: 550mm diameter; 150, 180; litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired. Single zone. IDEPLUHP150PPSZSL & IDEPLUHP180PPSZSL: 475mm diameter; 150, 180, litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; single zone. IDEPLUHP210PPDZ, IDEPLUHP250PPDZ & IDEPLUHP300PPDZ: 550mm diameter; 210, 250, 300 litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired. Two zone. IDEPLUHP210PPDZSL: 475mm diameter; 210 litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired. Two zone. IDEPLUHP180DUOPPSZ & IDEPLUHP210DUOPPSZ: 550mm diameter 180, 210, litre; single coil cylinders on top of a buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; single zone. IDEPLUHP250DUOPPSZ & IDEPLUHP300DUOPPSZ: 630mm diameter 250, 300 litre; single coil cylinders on top of a buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; single zone. IDEPLUHP180DUOPPDZ & IDEPLUHP210DUOPPDZ: 550mm diameter 180, 210, litre; single coil cylinders on top of a buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; two zone. IDEPLUHP250DUOPPDZ & IDEPLUHP300DUOPPDZ: 630mm diameter 250, 300 litre; single coil cylinders on top of a buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; Pre-plumbed and pre-wired; two zone. IDEPLUHP400: 630mm diameter; 400 litre; single coil cylinders intended for coupling with a range of heat pumps 5kW to 14 kW. IDEPLU090MB: 630mm diameter; 90 litre; buffer cylinder for coupling with a range of heat pumps 5kW to 14kW; and any cylinder without a buffer.
Factor:
Ideal Heating
Company Name
Ideal Heating
Address
National Avenue Hull East Yorkshire
Postcode
HU5 4JN

View All Listings by this Company

Print This Approval


Show Per Page
5102050Show All

Back To Directory Sections

Page of 1

We use cookies to give you the best possible experience with WRAS. Some are essential to provide website functions and ensure the website is secure. We also use cookies to help us understand how people use the site and to make improvements. Click "Accept All" to enable recommended settings or click "Manage cookies" to adjust your settings. For more details, see our Cookie Policy.